Characterization of baseline hemodynamics after the Fontan procedure: a retrospective cohort study on the comparison of 4D Flow MRI and computational fluid dynamics

Introduction: The aim of this study was to characterize the hemodynamics of Fontan patients using both four-dimensional flow magnetic resonance imaging (4D Flow MRI) and computational fluid dynamics (CFD). Methods: Twenty-nine patients (3.5 ± 0.5 years) who had undergone the Fontan procedure were en...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Gyu-Han, Koo, Hyun Jung, Park, Kyung Jin, Yang, Dong Hyun, Ha, Hojin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10248477/
https://www.ncbi.nlm.nih.gov/pubmed/37304827
http://dx.doi.org/10.3389/fphys.2023.1199771
_version_ 1785055383635623936
author Lee, Gyu-Han
Koo, Hyun Jung
Park, Kyung Jin
Yang, Dong Hyun
Ha, Hojin
author_facet Lee, Gyu-Han
Koo, Hyun Jung
Park, Kyung Jin
Yang, Dong Hyun
Ha, Hojin
author_sort Lee, Gyu-Han
collection PubMed
description Introduction: The aim of this study was to characterize the hemodynamics of Fontan patients using both four-dimensional flow magnetic resonance imaging (4D Flow MRI) and computational fluid dynamics (CFD). Methods: Twenty-nine patients (3.5 ± 0.5 years) who had undergone the Fontan procedure were enrolled, and the superior vena cava (SVC), left pulmonary artery (LPA), right pulmonary artery (RPA), and conduit were segmented based on 4D Flow MRI images. Velocity fields from 4D Flow MRI were used as boundary conditions for CFD simulations. Hemodynamic parameters such as peak velocity (Vmax), pulmonary flow distribution (PFD), kinetic energy (KE), and viscous dissipation (VD) were estimated and compared between the two modalities. Results and discussion: The Vmax, KE, VD, PFD(Total to LPA), and PFD(Total to RPA) of the Fontan circulation were 0.61 ± 0.18 m/s, 0.15 ± 0.04 mJ, 0.14 ± 0.04 mW, 41.3 ± 15.7%, and 58.7 ± 15.7% from 4D Flow MRI; and 0.42 ± 0.20 m/s, 0.12 ± 0.05 mJ, 0.59 ± 0.30 mW, 40.2 ± 16.4%, and 59.8 ± 16.4% from CFD, respectively. The overall velocity field, KE, and PFD from the SVC were in agreement between modalities. However, PFD from the conduit and VD showed a large discrepancy between 4D Flow MRI and CFD, most likely due to spatial resolution and data noise. This study highlights the necessity for careful consideration when analyzing hemodynamic data from different modalities in Fontan patients.
format Online
Article
Text
id pubmed-10248477
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-102484772023-06-09 Characterization of baseline hemodynamics after the Fontan procedure: a retrospective cohort study on the comparison of 4D Flow MRI and computational fluid dynamics Lee, Gyu-Han Koo, Hyun Jung Park, Kyung Jin Yang, Dong Hyun Ha, Hojin Front Physiol Physiology Introduction: The aim of this study was to characterize the hemodynamics of Fontan patients using both four-dimensional flow magnetic resonance imaging (4D Flow MRI) and computational fluid dynamics (CFD). Methods: Twenty-nine patients (3.5 ± 0.5 years) who had undergone the Fontan procedure were enrolled, and the superior vena cava (SVC), left pulmonary artery (LPA), right pulmonary artery (RPA), and conduit were segmented based on 4D Flow MRI images. Velocity fields from 4D Flow MRI were used as boundary conditions for CFD simulations. Hemodynamic parameters such as peak velocity (Vmax), pulmonary flow distribution (PFD), kinetic energy (KE), and viscous dissipation (VD) were estimated and compared between the two modalities. Results and discussion: The Vmax, KE, VD, PFD(Total to LPA), and PFD(Total to RPA) of the Fontan circulation were 0.61 ± 0.18 m/s, 0.15 ± 0.04 mJ, 0.14 ± 0.04 mW, 41.3 ± 15.7%, and 58.7 ± 15.7% from 4D Flow MRI; and 0.42 ± 0.20 m/s, 0.12 ± 0.05 mJ, 0.59 ± 0.30 mW, 40.2 ± 16.4%, and 59.8 ± 16.4% from CFD, respectively. The overall velocity field, KE, and PFD from the SVC were in agreement between modalities. However, PFD from the conduit and VD showed a large discrepancy between 4D Flow MRI and CFD, most likely due to spatial resolution and data noise. This study highlights the necessity for careful consideration when analyzing hemodynamic data from different modalities in Fontan patients. Frontiers Media S.A. 2023-05-25 /pmc/articles/PMC10248477/ /pubmed/37304827 http://dx.doi.org/10.3389/fphys.2023.1199771 Text en Copyright © 2023 Lee, Koo, Park, Yang and Ha. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Physiology
Lee, Gyu-Han
Koo, Hyun Jung
Park, Kyung Jin
Yang, Dong Hyun
Ha, Hojin
Characterization of baseline hemodynamics after the Fontan procedure: a retrospective cohort study on the comparison of 4D Flow MRI and computational fluid dynamics
title Characterization of baseline hemodynamics after the Fontan procedure: a retrospective cohort study on the comparison of 4D Flow MRI and computational fluid dynamics
title_full Characterization of baseline hemodynamics after the Fontan procedure: a retrospective cohort study on the comparison of 4D Flow MRI and computational fluid dynamics
title_fullStr Characterization of baseline hemodynamics after the Fontan procedure: a retrospective cohort study on the comparison of 4D Flow MRI and computational fluid dynamics
title_full_unstemmed Characterization of baseline hemodynamics after the Fontan procedure: a retrospective cohort study on the comparison of 4D Flow MRI and computational fluid dynamics
title_short Characterization of baseline hemodynamics after the Fontan procedure: a retrospective cohort study on the comparison of 4D Flow MRI and computational fluid dynamics
title_sort characterization of baseline hemodynamics after the fontan procedure: a retrospective cohort study on the comparison of 4d flow mri and computational fluid dynamics
topic Physiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10248477/
https://www.ncbi.nlm.nih.gov/pubmed/37304827
http://dx.doi.org/10.3389/fphys.2023.1199771
work_keys_str_mv AT leegyuhan characterizationofbaselinehemodynamicsafterthefontanprocedurearetrospectivecohortstudyonthecomparisonof4dflowmriandcomputationalfluiddynamics
AT koohyunjung characterizationofbaselinehemodynamicsafterthefontanprocedurearetrospectivecohortstudyonthecomparisonof4dflowmriandcomputationalfluiddynamics
AT parkkyungjin characterizationofbaselinehemodynamicsafterthefontanprocedurearetrospectivecohortstudyonthecomparisonof4dflowmriandcomputationalfluiddynamics
AT yangdonghyun characterizationofbaselinehemodynamicsafterthefontanprocedurearetrospectivecohortstudyonthecomparisonof4dflowmriandcomputationalfluiddynamics
AT hahojin characterizationofbaselinehemodynamicsafterthefontanprocedurearetrospectivecohortstudyonthecomparisonof4dflowmriandcomputationalfluiddynamics