Cargando…
Characterization of baseline hemodynamics after the Fontan procedure: a retrospective cohort study on the comparison of 4D Flow MRI and computational fluid dynamics
Introduction: The aim of this study was to characterize the hemodynamics of Fontan patients using both four-dimensional flow magnetic resonance imaging (4D Flow MRI) and computational fluid dynamics (CFD). Methods: Twenty-nine patients (3.5 ± 0.5 years) who had undergone the Fontan procedure were en...
Autores principales: | Lee, Gyu-Han, Koo, Hyun Jung, Park, Kyung Jin, Yang, Dong Hyun, Ha, Hojin |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10248477/ https://www.ncbi.nlm.nih.gov/pubmed/37304827 http://dx.doi.org/10.3389/fphys.2023.1199771 |
Ejemplares similares
-
The prediction and verification of outcome of extracardiac conduits fontan based on computational fluid dynamics simulation
por: Zhang, Yong, et al.
Publicado: (2022) -
Impact of pulmonary artery flow distribution on Fontan hemodynamics and flow energetics
por: Weiss, Elizabeth K., et al.
Publicado: (2023) -
Cerebral hemodynamics comparison using transcranial doppler ultrasound and 4D flow MRI
por: Fico, Brandon G., et al.
Publicado: (2023) -
Development of a computational fluid dynamic model to investigate the hemodynamic impact of REBOA
por: Renaldo, Antonio C., et al.
Publicado: (2022) -
Optimal Fenestration of the Fontan Circulation
por: Ahmad, Zan, et al.
Publicado: (2022)