Cargando…

Determination of Phosphoethanolamine in Urine with HPLC-ICPMS/MS Using 1,2-Hexanediol as a Chromatographic Eluent

[Image: see text] The importance of element-selective detection with inductively coupled plasma mass spectrometry (ICPMS) has been significantly increased in recent years following the introduction of tandem ICPMS (ICPMS/MS), which unlocked access to nonmetal speciation analysis. However, nonmetals...

Descripción completa

Detalles Bibliográficos
Autores principales: Lajin, Bassam, Goessler, Walter
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2023
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10248998/
https://www.ncbi.nlm.nih.gov/pubmed/37216218
http://dx.doi.org/10.1021/acs.analchem.3c01364
Descripción
Sumario:[Image: see text] The importance of element-selective detection with inductively coupled plasma mass spectrometry (ICPMS) has been significantly increased in recent years following the introduction of tandem ICPMS (ICPMS/MS), which unlocked access to nonmetal speciation analysis. However, nonmetals are ubiquitous, and the feasibility of nonmetal speciation analysis in matrices with complex metabolomes is yet to be demonstrated. Herein, we report the first phosphorous speciation study by HPLC-ICPMS/MS in a human sample, namely, urine, involving the determination of the natural metabolite and biomarker phosphoethanolamine. A simple one-step derivatization procedure was employed to enable the separation of the target compound from the hydrophilic phosphorous metabolome in urine. The challenge of eluting the hydrophobic derivative under ICPMS-compatible chromatographic conditions was addressed by employing hexanediol, a novel chromatographic eluent recently described in our previous work but has not yet been exploited in a real-world application. The developed method features fast chromatographic separation (<5 min), no need for an isotopically labeled internal standard, and an instrumental LOD of 0.5 μg P L(–1). The method was evaluated for recovery (90–110%), repeatability (RSD ±5%), and linearity (r(2) = 0.9998). The method accuracy was thoroughly examined by comparing with an independently developed method based on HPLC-ESIMS/MS without derivatization, where agreement was found within ±5–20%. An application is presented to gain first insight into the variability in the human excretion of phosphoethanolamine, which is key for the interpretation of its levels as a biomarker, by repeated urine collection from a group of volunteers over 4 weeks.