Cargando…
Intra- and inter-rater reliability, agreement, and minimal detectable change of the handheld dynamometer in individuals with symptomatic hip osteoarthritis
INTRODUCTION: The handheld dynamometer has been validated to measure muscle strength in different muscle groups. However, to date, it has not been tested in individuals who experience pain induced by hip osteoarthritis. The current study aimed to evaluate the intra- and inter-rater reliability, agre...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10249871/ https://www.ncbi.nlm.nih.gov/pubmed/37289803 http://dx.doi.org/10.1371/journal.pone.0278086 |
_version_ | 1785055637418278912 |
---|---|
author | Vaz, Gilvan Ferreira Freire, Felipe Florêncio Gonçalves, Henrique Mansur de Aviz, Marcus Alexandre Brito Martins, Wagner Rodrigues Durigan, João Luiz Quagliotti |
author_facet | Vaz, Gilvan Ferreira Freire, Felipe Florêncio Gonçalves, Henrique Mansur de Aviz, Marcus Alexandre Brito Martins, Wagner Rodrigues Durigan, João Luiz Quagliotti |
author_sort | Vaz, Gilvan Ferreira |
collection | PubMed |
description | INTRODUCTION: The handheld dynamometer has been validated to measure muscle strength in different muscle groups. However, to date, it has not been tested in individuals who experience pain induced by hip osteoarthritis. The current study aimed to evaluate the intra- and inter-rater reliability, agreement, and minimal detectable change of the Lafayette handheld dynamometer, model 1165, to assess the peak force (Pk) and average peak force (Af) of hip muscles in individuals with symptomatic hip osteoarthritis. METHODS: Twenty participants with hip osteoarthritis (mean ± SD age: 58.7±15.3 years; body mass index: 28.8±4.2 kg/m(2)) and pain intensity on the Visual Analogue Scale ≥ 4 (8.05±1.2) were recruited to participate in this study. Pk and Af of hip flexors (seated position), abductors and adductors (supine position), and extensors (prone position) were collected in a single day by two independent raters, each one obtaining test and retest in randomly ordered separate sessions. RESULTS: The intra-rater intraclass correlation coefficient (ICC) was classified as good (>0.75) or excellent (≥0.90) for all muscle groups and all inter-rater ICCs were classified as excellent. Rater A had a lower standard error of measurement compared to rater B, ranging from 0.15 to 0.58 kilogram-force (Kgf) compared with 0.34 to 1.25 kg, respectively. However, the inter-rater comparison showed a minimal detectable change (MDC) of < 10% for all Pk and Af measures for hip adductors and extensors. Finally, the inter-rater Bland-Altman analysis demonstrated good agreement for abductors, adductors, and extensors. CONCLUSION: Despite pain and dysfunction related to hip osteoarthritis, the mean of two measures using a handheld dynamometer was shown to be a reliable tool to assess hip muscle strength, with good to excellent intra- and inter-rater ICCs, satisfactory agreement, and small values for MDC. |
format | Online Article Text |
id | pubmed-10249871 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-102498712023-06-09 Intra- and inter-rater reliability, agreement, and minimal detectable change of the handheld dynamometer in individuals with symptomatic hip osteoarthritis Vaz, Gilvan Ferreira Freire, Felipe Florêncio Gonçalves, Henrique Mansur de Aviz, Marcus Alexandre Brito Martins, Wagner Rodrigues Durigan, João Luiz Quagliotti PLoS One Research Article INTRODUCTION: The handheld dynamometer has been validated to measure muscle strength in different muscle groups. However, to date, it has not been tested in individuals who experience pain induced by hip osteoarthritis. The current study aimed to evaluate the intra- and inter-rater reliability, agreement, and minimal detectable change of the Lafayette handheld dynamometer, model 1165, to assess the peak force (Pk) and average peak force (Af) of hip muscles in individuals with symptomatic hip osteoarthritis. METHODS: Twenty participants with hip osteoarthritis (mean ± SD age: 58.7±15.3 years; body mass index: 28.8±4.2 kg/m(2)) and pain intensity on the Visual Analogue Scale ≥ 4 (8.05±1.2) were recruited to participate in this study. Pk and Af of hip flexors (seated position), abductors and adductors (supine position), and extensors (prone position) were collected in a single day by two independent raters, each one obtaining test and retest in randomly ordered separate sessions. RESULTS: The intra-rater intraclass correlation coefficient (ICC) was classified as good (>0.75) or excellent (≥0.90) for all muscle groups and all inter-rater ICCs were classified as excellent. Rater A had a lower standard error of measurement compared to rater B, ranging from 0.15 to 0.58 kilogram-force (Kgf) compared with 0.34 to 1.25 kg, respectively. However, the inter-rater comparison showed a minimal detectable change (MDC) of < 10% for all Pk and Af measures for hip adductors and extensors. Finally, the inter-rater Bland-Altman analysis demonstrated good agreement for abductors, adductors, and extensors. CONCLUSION: Despite pain and dysfunction related to hip osteoarthritis, the mean of two measures using a handheld dynamometer was shown to be a reliable tool to assess hip muscle strength, with good to excellent intra- and inter-rater ICCs, satisfactory agreement, and small values for MDC. Public Library of Science 2023-06-08 /pmc/articles/PMC10249871/ /pubmed/37289803 http://dx.doi.org/10.1371/journal.pone.0278086 Text en © 2023 Vaz et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Vaz, Gilvan Ferreira Freire, Felipe Florêncio Gonçalves, Henrique Mansur de Aviz, Marcus Alexandre Brito Martins, Wagner Rodrigues Durigan, João Luiz Quagliotti Intra- and inter-rater reliability, agreement, and minimal detectable change of the handheld dynamometer in individuals with symptomatic hip osteoarthritis |
title | Intra- and inter-rater reliability, agreement, and minimal detectable change of the handheld dynamometer in individuals with symptomatic hip osteoarthritis |
title_full | Intra- and inter-rater reliability, agreement, and minimal detectable change of the handheld dynamometer in individuals with symptomatic hip osteoarthritis |
title_fullStr | Intra- and inter-rater reliability, agreement, and minimal detectable change of the handheld dynamometer in individuals with symptomatic hip osteoarthritis |
title_full_unstemmed | Intra- and inter-rater reliability, agreement, and minimal detectable change of the handheld dynamometer in individuals with symptomatic hip osteoarthritis |
title_short | Intra- and inter-rater reliability, agreement, and minimal detectable change of the handheld dynamometer in individuals with symptomatic hip osteoarthritis |
title_sort | intra- and inter-rater reliability, agreement, and minimal detectable change of the handheld dynamometer in individuals with symptomatic hip osteoarthritis |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10249871/ https://www.ncbi.nlm.nih.gov/pubmed/37289803 http://dx.doi.org/10.1371/journal.pone.0278086 |
work_keys_str_mv | AT vazgilvanferreira intraandinterraterreliabilityagreementandminimaldetectablechangeofthehandhelddynamometerinindividualswithsymptomatichiposteoarthritis AT freirefelipeflorencio intraandinterraterreliabilityagreementandminimaldetectablechangeofthehandhelddynamometerinindividualswithsymptomatichiposteoarthritis AT goncalveshenriquemansur intraandinterraterreliabilityagreementandminimaldetectablechangeofthehandhelddynamometerinindividualswithsymptomatichiposteoarthritis AT deavizmarcusalexandrebrito intraandinterraterreliabilityagreementandminimaldetectablechangeofthehandhelddynamometerinindividualswithsymptomatichiposteoarthritis AT martinswagnerrodrigues intraandinterraterreliabilityagreementandminimaldetectablechangeofthehandhelddynamometerinindividualswithsymptomatichiposteoarthritis AT duriganjoaoluizquagliotti intraandinterraterreliabilityagreementandminimaldetectablechangeofthehandhelddynamometerinindividualswithsymptomatichiposteoarthritis |