Cargando…
Delayed Sentinel Lymph Node Dissection in Patients with a Preoperative Diagnosis of Ductal Cancer In Situ by Preoperative Injection with Superparamagnetic Iron Oxide (SPIO) Nanoparticles: The SentiNot Study
BACKGROUND: Difficulty in preoperatively assessing the risk for occult invasion or surgery that precludes future accurate axillary mapping in patients with ductal cancer in situ (DCIS) account for overutilization of SLND. METHODS: Prospective, multicenter, cohort study, including women with any DCIS...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10250503/ https://www.ncbi.nlm.nih.gov/pubmed/36719570 http://dx.doi.org/10.1245/s10434-022-13064-0 |
_version_ | 1785055767023321088 |
---|---|
author | Karakatsanis, Andreas Eriksson, Staffan Pistiolis, Lida Olofsson Bagge, Roger Nagy, Gyula Man, Vivian Kwong, Ava Wärnberg, Fredrik |
author_facet | Karakatsanis, Andreas Eriksson, Staffan Pistiolis, Lida Olofsson Bagge, Roger Nagy, Gyula Man, Vivian Kwong, Ava Wärnberg, Fredrik |
author_sort | Karakatsanis, Andreas |
collection | PubMed |
description | BACKGROUND: Difficulty in preoperatively assessing the risk for occult invasion or surgery that precludes future accurate axillary mapping in patients with ductal cancer in situ (DCIS) account for overutilization of SLND. METHODS: Prospective, multicenter, cohort study, including women with any DCIS planned for mastectomy or DCIS grade 2 and > 20 mm, any DCIS grade 3, any mass-forming DCIS and any planned surgery. Patients received an interstitial SPIO injection during breast surgery, but no upfront SLND was performed. If invasion was identified on final pathology, delayed SLND (d-SLND) was performed separately with the coadministration of isotope ± blue dye (BD). Study outcomes were proportion of upfront SLNDs that were avoided, detection rates during d-SLND, and impact on healthcare costs. RESULTS: In total, 78.7% of study participants (N = 254, mean age 60 years, mean DCIS size 37.8 mm) avoided upfront SLND. On d-SLND (median 28 days, range 9–46), SPIO outperformed Tc(99) with (98.2% vs. 63.6%, p < 0.001) or without BD (92.7% vs. 50.9%, p < 0.001) and had higher nodal detection rate (86.9% vs. 32.3%, p < 0.001) and with BD (93.9% vs. 41.4%, p < 0.001). Only 27.9% of all SLNs retrieved were concordant for Tc(99) and SPIO. Type of breast procedure (WLE vs. oncoplastic BCT vs. mastectomy) affected these outcomes and accounted for the low performance of Tc(99) (p < 0.001). d-SLND resulted in a 28.1% total cost containment for women with pure DCIS on final pathology (4190 vs. 5828 USD, p < 0.001). CONCLUSIONS: Marking the SLN with SPIO may avoid overtreatment and allow for accurate d-SLND in patients with DCIS. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1245/s10434-022-13064-0. |
format | Online Article Text |
id | pubmed-10250503 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-102505032023-06-10 Delayed Sentinel Lymph Node Dissection in Patients with a Preoperative Diagnosis of Ductal Cancer In Situ by Preoperative Injection with Superparamagnetic Iron Oxide (SPIO) Nanoparticles: The SentiNot Study Karakatsanis, Andreas Eriksson, Staffan Pistiolis, Lida Olofsson Bagge, Roger Nagy, Gyula Man, Vivian Kwong, Ava Wärnberg, Fredrik Ann Surg Oncol Breast Oncology BACKGROUND: Difficulty in preoperatively assessing the risk for occult invasion or surgery that precludes future accurate axillary mapping in patients with ductal cancer in situ (DCIS) account for overutilization of SLND. METHODS: Prospective, multicenter, cohort study, including women with any DCIS planned for mastectomy or DCIS grade 2 and > 20 mm, any DCIS grade 3, any mass-forming DCIS and any planned surgery. Patients received an interstitial SPIO injection during breast surgery, but no upfront SLND was performed. If invasion was identified on final pathology, delayed SLND (d-SLND) was performed separately with the coadministration of isotope ± blue dye (BD). Study outcomes were proportion of upfront SLNDs that were avoided, detection rates during d-SLND, and impact on healthcare costs. RESULTS: In total, 78.7% of study participants (N = 254, mean age 60 years, mean DCIS size 37.8 mm) avoided upfront SLND. On d-SLND (median 28 days, range 9–46), SPIO outperformed Tc(99) with (98.2% vs. 63.6%, p < 0.001) or without BD (92.7% vs. 50.9%, p < 0.001) and had higher nodal detection rate (86.9% vs. 32.3%, p < 0.001) and with BD (93.9% vs. 41.4%, p < 0.001). Only 27.9% of all SLNs retrieved were concordant for Tc(99) and SPIO. Type of breast procedure (WLE vs. oncoplastic BCT vs. mastectomy) affected these outcomes and accounted for the low performance of Tc(99) (p < 0.001). d-SLND resulted in a 28.1% total cost containment for women with pure DCIS on final pathology (4190 vs. 5828 USD, p < 0.001). CONCLUSIONS: Marking the SLN with SPIO may avoid overtreatment and allow for accurate d-SLND in patients with DCIS. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1245/s10434-022-13064-0. Springer International Publishing 2023-01-31 2023 /pmc/articles/PMC10250503/ /pubmed/36719570 http://dx.doi.org/10.1245/s10434-022-13064-0 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Breast Oncology Karakatsanis, Andreas Eriksson, Staffan Pistiolis, Lida Olofsson Bagge, Roger Nagy, Gyula Man, Vivian Kwong, Ava Wärnberg, Fredrik Delayed Sentinel Lymph Node Dissection in Patients with a Preoperative Diagnosis of Ductal Cancer In Situ by Preoperative Injection with Superparamagnetic Iron Oxide (SPIO) Nanoparticles: The SentiNot Study |
title | Delayed Sentinel Lymph Node Dissection in Patients with a Preoperative Diagnosis of Ductal Cancer In Situ by Preoperative Injection with Superparamagnetic Iron Oxide (SPIO) Nanoparticles: The SentiNot Study |
title_full | Delayed Sentinel Lymph Node Dissection in Patients with a Preoperative Diagnosis of Ductal Cancer In Situ by Preoperative Injection with Superparamagnetic Iron Oxide (SPIO) Nanoparticles: The SentiNot Study |
title_fullStr | Delayed Sentinel Lymph Node Dissection in Patients with a Preoperative Diagnosis of Ductal Cancer In Situ by Preoperative Injection with Superparamagnetic Iron Oxide (SPIO) Nanoparticles: The SentiNot Study |
title_full_unstemmed | Delayed Sentinel Lymph Node Dissection in Patients with a Preoperative Diagnosis of Ductal Cancer In Situ by Preoperative Injection with Superparamagnetic Iron Oxide (SPIO) Nanoparticles: The SentiNot Study |
title_short | Delayed Sentinel Lymph Node Dissection in Patients with a Preoperative Diagnosis of Ductal Cancer In Situ by Preoperative Injection with Superparamagnetic Iron Oxide (SPIO) Nanoparticles: The SentiNot Study |
title_sort | delayed sentinel lymph node dissection in patients with a preoperative diagnosis of ductal cancer in situ by preoperative injection with superparamagnetic iron oxide (spio) nanoparticles: the sentinot study |
topic | Breast Oncology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10250503/ https://www.ncbi.nlm.nih.gov/pubmed/36719570 http://dx.doi.org/10.1245/s10434-022-13064-0 |
work_keys_str_mv | AT karakatsanisandreas delayedsentinellymphnodedissectioninpatientswithapreoperativediagnosisofductalcancerinsitubypreoperativeinjectionwithsuperparamagneticironoxidespionanoparticlesthesentinotstudy AT erikssonstaffan delayedsentinellymphnodedissectioninpatientswithapreoperativediagnosisofductalcancerinsitubypreoperativeinjectionwithsuperparamagneticironoxidespionanoparticlesthesentinotstudy AT pistiolislida delayedsentinellymphnodedissectioninpatientswithapreoperativediagnosisofductalcancerinsitubypreoperativeinjectionwithsuperparamagneticironoxidespionanoparticlesthesentinotstudy AT olofssonbaggeroger delayedsentinellymphnodedissectioninpatientswithapreoperativediagnosisofductalcancerinsitubypreoperativeinjectionwithsuperparamagneticironoxidespionanoparticlesthesentinotstudy AT nagygyula delayedsentinellymphnodedissectioninpatientswithapreoperativediagnosisofductalcancerinsitubypreoperativeinjectionwithsuperparamagneticironoxidespionanoparticlesthesentinotstudy AT manvivian delayedsentinellymphnodedissectioninpatientswithapreoperativediagnosisofductalcancerinsitubypreoperativeinjectionwithsuperparamagneticironoxidespionanoparticlesthesentinotstudy AT kwongava delayedsentinellymphnodedissectioninpatientswithapreoperativediagnosisofductalcancerinsitubypreoperativeinjectionwithsuperparamagneticironoxidespionanoparticlesthesentinotstudy AT warnbergfredrik delayedsentinellymphnodedissectioninpatientswithapreoperativediagnosisofductalcancerinsitubypreoperativeinjectionwithsuperparamagneticironoxidespionanoparticlesthesentinotstudy AT delayedsentinellymphnodedissectioninpatientswithapreoperativediagnosisofductalcancerinsitubypreoperativeinjectionwithsuperparamagneticironoxidespionanoparticlesthesentinotstudy |