Cargando…

Efficacy of Fully Covered Self-Expandable Metal Stents for Distal Biliary Obstruction Caused by Pancreatic Ductal Adenocarcinoma: Primary Metal Stent vs. Metal Stent following Plastic Stent

SIMPLE SUMMARY: Pancreatic ductal adenocarcinoma can cause distal bile duct obstruction. Fully covered biliary self-expandable metal stents (FCSEMSs) are widely used for bile duct drainage to prevent tissue ingrowth and can be easily exchanged. This retrospective study aimed to compare the efficacy...

Descripción completa

Detalles Bibliográficos
Autores principales: Wu, Chi-Huan, Wang, Sheng-Fu, Lee, Mu-Hsien, Tsou, Yung-Kuan, Lin, Cheng-Hui, Chang, Li-Ling, Sung, Kai-Feng, Liu, Nai-Jen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10251881/
https://www.ncbi.nlm.nih.gov/pubmed/37296962
http://dx.doi.org/10.3390/cancers15113001
_version_ 1785056038068682752
author Wu, Chi-Huan
Wang, Sheng-Fu
Lee, Mu-Hsien
Tsou, Yung-Kuan
Lin, Cheng-Hui
Chang, Li-Ling
Sung, Kai-Feng
Liu, Nai-Jen
author_facet Wu, Chi-Huan
Wang, Sheng-Fu
Lee, Mu-Hsien
Tsou, Yung-Kuan
Lin, Cheng-Hui
Chang, Li-Ling
Sung, Kai-Feng
Liu, Nai-Jen
author_sort Wu, Chi-Huan
collection PubMed
description SIMPLE SUMMARY: Pancreatic ductal adenocarcinoma can cause distal bile duct obstruction. Fully covered biliary self-expandable metal stents (FCSEMSs) are widely used for bile duct drainage to prevent tissue ingrowth and can be easily exchanged. This retrospective study aimed to compare the efficacy of FCSEMSs placed in a first session of endoscopic retrograde cholangiopancreatography with that of FCSEMSs placed following a prior plastic stent. We also assessed the risk factors for recurrent biliary obstruction of FCSEMSs. We found that the time to recurrent biliary obstruction was comparable between the primary use of FCSEMSs and FCSEMSs with prior plastic stents. We also found that FCSEMS length was associated with dysfunction. These findings provide clinical evidence for the use of FCSEMSs in patients with pancreatic ductal adenocarcinoma and malignant distal obstruction. ABSTRACT: Fully covered self-expandable metallic stents (FCSEMSs) are inserted in patients with unresectable pancreatic ductal adenocarcinoma (PDAC) to resolve malignant distal bile duct obstructions. Some patients receive FCSEMSs during primary endoscopic retrograde cholangiopancreatography (ERCP), and others receive FCSEMSs during a later session, after the placement of a plastic stent. We aimed to evaluate the efficacy of FCSEMSs for primary use or following plastic stent placement. A total of 159 patients with pancreatic adenocarcinoma (m:f, 102:57) who had achieved clinical success underwent ERCP with the placement of FCSEMSs for palliation of obstructive jaundice. One-hundred and three patients had received FCSEMSs in a first ERCP, and 56 had received FCSEMSs after prior plastic stenting. Twenty-two patients in the primary metal stent group and 18 in the prior plastic stent group had recurrent biliary obstruction (RBO). The RBO rates and self-expandable metal stent patency duration did not differ between the two groups. An FCSEMS longer than 6 cm was identified as a risk factor for RBO in patients with PDAC. Thus, choosing an appropriate FCSEMS length is an important factor in preventing FCSEMS dysfunction in patients with PDAC with malignant distal bile-duct obstruction.
format Online
Article
Text
id pubmed-10251881
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-102518812023-06-10 Efficacy of Fully Covered Self-Expandable Metal Stents for Distal Biliary Obstruction Caused by Pancreatic Ductal Adenocarcinoma: Primary Metal Stent vs. Metal Stent following Plastic Stent Wu, Chi-Huan Wang, Sheng-Fu Lee, Mu-Hsien Tsou, Yung-Kuan Lin, Cheng-Hui Chang, Li-Ling Sung, Kai-Feng Liu, Nai-Jen Cancers (Basel) Article SIMPLE SUMMARY: Pancreatic ductal adenocarcinoma can cause distal bile duct obstruction. Fully covered biliary self-expandable metal stents (FCSEMSs) are widely used for bile duct drainage to prevent tissue ingrowth and can be easily exchanged. This retrospective study aimed to compare the efficacy of FCSEMSs placed in a first session of endoscopic retrograde cholangiopancreatography with that of FCSEMSs placed following a prior plastic stent. We also assessed the risk factors for recurrent biliary obstruction of FCSEMSs. We found that the time to recurrent biliary obstruction was comparable between the primary use of FCSEMSs and FCSEMSs with prior plastic stents. We also found that FCSEMS length was associated with dysfunction. These findings provide clinical evidence for the use of FCSEMSs in patients with pancreatic ductal adenocarcinoma and malignant distal obstruction. ABSTRACT: Fully covered self-expandable metallic stents (FCSEMSs) are inserted in patients with unresectable pancreatic ductal adenocarcinoma (PDAC) to resolve malignant distal bile duct obstructions. Some patients receive FCSEMSs during primary endoscopic retrograde cholangiopancreatography (ERCP), and others receive FCSEMSs during a later session, after the placement of a plastic stent. We aimed to evaluate the efficacy of FCSEMSs for primary use or following plastic stent placement. A total of 159 patients with pancreatic adenocarcinoma (m:f, 102:57) who had achieved clinical success underwent ERCP with the placement of FCSEMSs for palliation of obstructive jaundice. One-hundred and three patients had received FCSEMSs in a first ERCP, and 56 had received FCSEMSs after prior plastic stenting. Twenty-two patients in the primary metal stent group and 18 in the prior plastic stent group had recurrent biliary obstruction (RBO). The RBO rates and self-expandable metal stent patency duration did not differ between the two groups. An FCSEMS longer than 6 cm was identified as a risk factor for RBO in patients with PDAC. Thus, choosing an appropriate FCSEMS length is an important factor in preventing FCSEMS dysfunction in patients with PDAC with malignant distal bile-duct obstruction. MDPI 2023-05-31 /pmc/articles/PMC10251881/ /pubmed/37296962 http://dx.doi.org/10.3390/cancers15113001 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Wu, Chi-Huan
Wang, Sheng-Fu
Lee, Mu-Hsien
Tsou, Yung-Kuan
Lin, Cheng-Hui
Chang, Li-Ling
Sung, Kai-Feng
Liu, Nai-Jen
Efficacy of Fully Covered Self-Expandable Metal Stents for Distal Biliary Obstruction Caused by Pancreatic Ductal Adenocarcinoma: Primary Metal Stent vs. Metal Stent following Plastic Stent
title Efficacy of Fully Covered Self-Expandable Metal Stents for Distal Biliary Obstruction Caused by Pancreatic Ductal Adenocarcinoma: Primary Metal Stent vs. Metal Stent following Plastic Stent
title_full Efficacy of Fully Covered Self-Expandable Metal Stents for Distal Biliary Obstruction Caused by Pancreatic Ductal Adenocarcinoma: Primary Metal Stent vs. Metal Stent following Plastic Stent
title_fullStr Efficacy of Fully Covered Self-Expandable Metal Stents for Distal Biliary Obstruction Caused by Pancreatic Ductal Adenocarcinoma: Primary Metal Stent vs. Metal Stent following Plastic Stent
title_full_unstemmed Efficacy of Fully Covered Self-Expandable Metal Stents for Distal Biliary Obstruction Caused by Pancreatic Ductal Adenocarcinoma: Primary Metal Stent vs. Metal Stent following Plastic Stent
title_short Efficacy of Fully Covered Self-Expandable Metal Stents for Distal Biliary Obstruction Caused by Pancreatic Ductal Adenocarcinoma: Primary Metal Stent vs. Metal Stent following Plastic Stent
title_sort efficacy of fully covered self-expandable metal stents for distal biliary obstruction caused by pancreatic ductal adenocarcinoma: primary metal stent vs. metal stent following plastic stent
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10251881/
https://www.ncbi.nlm.nih.gov/pubmed/37296962
http://dx.doi.org/10.3390/cancers15113001
work_keys_str_mv AT wuchihuan efficacyoffullycoveredselfexpandablemetalstentsfordistalbiliaryobstructioncausedbypancreaticductaladenocarcinomaprimarymetalstentvsmetalstentfollowingplasticstent
AT wangshengfu efficacyoffullycoveredselfexpandablemetalstentsfordistalbiliaryobstructioncausedbypancreaticductaladenocarcinomaprimarymetalstentvsmetalstentfollowingplasticstent
AT leemuhsien efficacyoffullycoveredselfexpandablemetalstentsfordistalbiliaryobstructioncausedbypancreaticductaladenocarcinomaprimarymetalstentvsmetalstentfollowingplasticstent
AT tsouyungkuan efficacyoffullycoveredselfexpandablemetalstentsfordistalbiliaryobstructioncausedbypancreaticductaladenocarcinomaprimarymetalstentvsmetalstentfollowingplasticstent
AT linchenghui efficacyoffullycoveredselfexpandablemetalstentsfordistalbiliaryobstructioncausedbypancreaticductaladenocarcinomaprimarymetalstentvsmetalstentfollowingplasticstent
AT changliling efficacyoffullycoveredselfexpandablemetalstentsfordistalbiliaryobstructioncausedbypancreaticductaladenocarcinomaprimarymetalstentvsmetalstentfollowingplasticstent
AT sungkaifeng efficacyoffullycoveredselfexpandablemetalstentsfordistalbiliaryobstructioncausedbypancreaticductaladenocarcinomaprimarymetalstentvsmetalstentfollowingplasticstent
AT liunaijen efficacyoffullycoveredselfexpandablemetalstentsfordistalbiliaryobstructioncausedbypancreaticductaladenocarcinomaprimarymetalstentvsmetalstentfollowingplasticstent