Cargando…

Endoleak Detection after Endovascular Aortic Repair via Coded-Excitation Ultrasound—A Feasibility Study

Endoleaks are the most common complication after endovascular aortic repair (EVAR). Their correct identification is one of the main objectives of surveillance protocols after EVAR. So far, computed tomography angiography (CTA), contrast-enhanced (CEUS) and Duplex ultrasound (DUS), as well as magneti...

Descripción completa

Detalles Bibliográficos
Autores principales: Hofmann, Amun G., Klosz, Fabian R., Mlekusch, Irene, Wickenhauser, Georg, Walter, Corinna, Assadian, Afshin, Taher, Fadi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10253653/
https://www.ncbi.nlm.nih.gov/pubmed/37297970
http://dx.doi.org/10.3390/jcm12113775
_version_ 1785056457539977216
author Hofmann, Amun G.
Klosz, Fabian R.
Mlekusch, Irene
Wickenhauser, Georg
Walter, Corinna
Assadian, Afshin
Taher, Fadi
author_facet Hofmann, Amun G.
Klosz, Fabian R.
Mlekusch, Irene
Wickenhauser, Georg
Walter, Corinna
Assadian, Afshin
Taher, Fadi
author_sort Hofmann, Amun G.
collection PubMed
description Endoleaks are the most common complication after endovascular aortic repair (EVAR). Their correct identification is one of the main objectives of surveillance protocols after EVAR. So far, computed tomography angiography (CTA), contrast-enhanced (CEUS) and Duplex ultrasound (DUS), as well as magnetic resonance angiography, have been investigated for their ability to detect endoleaks. In general, all technologies have distinct benefits and disadvantages, with CTA and CEUS emerging as the reference standard for surveillance after EVAR. However, they are both contrast-enhancer-dependent, and CTA additionally exposes patients to ionizing radiation. In the present study, we investigated B-Flow, a type of coded-excitation ultrasound that was specifically designed to optimize the visualization of blood flow, for its ability to detect endoleaks, and compared its performance to CEUS, CTA, and DUS. In total, 34 patients were included in the analysis that accumulated in 43 distinct B-Flow investigations. They underwent a total of 132 imaging investigations. Agreement between B-Flow and other imaging modalities was high (>80.0%), while inter-method reliability can be interpreted as good. However, with B-Flow, six and one endoleaks would have been missed compared to CEUS and CTA, respectively. Regarding endoleak classification, all metrics were lower but retained an adequate level of comparison. In a subset of patients requiring intervention, B-Flow had 100% accuracy regarding both endoleak detection and classification. Ultrasonography enables endoleak detection and classification without the need for pharmaceutical contrast enhancement or radiation. Ultrasound coded-excitation imaging in the application of B-Flow could further simplify surveillance after EVAR by offering adequate accuracy without requiring intravenous contrast enhancement. Our findings may promote subsequent investigations of coded-excitation imaging for endoleak detection and classification in the surveillance after EVAR.
format Online
Article
Text
id pubmed-10253653
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-102536532023-06-10 Endoleak Detection after Endovascular Aortic Repair via Coded-Excitation Ultrasound—A Feasibility Study Hofmann, Amun G. Klosz, Fabian R. Mlekusch, Irene Wickenhauser, Georg Walter, Corinna Assadian, Afshin Taher, Fadi J Clin Med Article Endoleaks are the most common complication after endovascular aortic repair (EVAR). Their correct identification is one of the main objectives of surveillance protocols after EVAR. So far, computed tomography angiography (CTA), contrast-enhanced (CEUS) and Duplex ultrasound (DUS), as well as magnetic resonance angiography, have been investigated for their ability to detect endoleaks. In general, all technologies have distinct benefits and disadvantages, with CTA and CEUS emerging as the reference standard for surveillance after EVAR. However, they are both contrast-enhancer-dependent, and CTA additionally exposes patients to ionizing radiation. In the present study, we investigated B-Flow, a type of coded-excitation ultrasound that was specifically designed to optimize the visualization of blood flow, for its ability to detect endoleaks, and compared its performance to CEUS, CTA, and DUS. In total, 34 patients were included in the analysis that accumulated in 43 distinct B-Flow investigations. They underwent a total of 132 imaging investigations. Agreement between B-Flow and other imaging modalities was high (>80.0%), while inter-method reliability can be interpreted as good. However, with B-Flow, six and one endoleaks would have been missed compared to CEUS and CTA, respectively. Regarding endoleak classification, all metrics were lower but retained an adequate level of comparison. In a subset of patients requiring intervention, B-Flow had 100% accuracy regarding both endoleak detection and classification. Ultrasonography enables endoleak detection and classification without the need for pharmaceutical contrast enhancement or radiation. Ultrasound coded-excitation imaging in the application of B-Flow could further simplify surveillance after EVAR by offering adequate accuracy without requiring intravenous contrast enhancement. Our findings may promote subsequent investigations of coded-excitation imaging for endoleak detection and classification in the surveillance after EVAR. MDPI 2023-05-31 /pmc/articles/PMC10253653/ /pubmed/37297970 http://dx.doi.org/10.3390/jcm12113775 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Hofmann, Amun G.
Klosz, Fabian R.
Mlekusch, Irene
Wickenhauser, Georg
Walter, Corinna
Assadian, Afshin
Taher, Fadi
Endoleak Detection after Endovascular Aortic Repair via Coded-Excitation Ultrasound—A Feasibility Study
title Endoleak Detection after Endovascular Aortic Repair via Coded-Excitation Ultrasound—A Feasibility Study
title_full Endoleak Detection after Endovascular Aortic Repair via Coded-Excitation Ultrasound—A Feasibility Study
title_fullStr Endoleak Detection after Endovascular Aortic Repair via Coded-Excitation Ultrasound—A Feasibility Study
title_full_unstemmed Endoleak Detection after Endovascular Aortic Repair via Coded-Excitation Ultrasound—A Feasibility Study
title_short Endoleak Detection after Endovascular Aortic Repair via Coded-Excitation Ultrasound—A Feasibility Study
title_sort endoleak detection after endovascular aortic repair via coded-excitation ultrasound—a feasibility study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10253653/
https://www.ncbi.nlm.nih.gov/pubmed/37297970
http://dx.doi.org/10.3390/jcm12113775
work_keys_str_mv AT hofmannamung endoleakdetectionafterendovascularaorticrepairviacodedexcitationultrasoundafeasibilitystudy
AT kloszfabianr endoleakdetectionafterendovascularaorticrepairviacodedexcitationultrasoundafeasibilitystudy
AT mlekuschirene endoleakdetectionafterendovascularaorticrepairviacodedexcitationultrasoundafeasibilitystudy
AT wickenhausergeorg endoleakdetectionafterendovascularaorticrepairviacodedexcitationultrasoundafeasibilitystudy
AT waltercorinna endoleakdetectionafterendovascularaorticrepairviacodedexcitationultrasoundafeasibilitystudy
AT assadianafshin endoleakdetectionafterendovascularaorticrepairviacodedexcitationultrasoundafeasibilitystudy
AT taherfadi endoleakdetectionafterendovascularaorticrepairviacodedexcitationultrasoundafeasibilitystudy