Cargando…
Dual Source Photon-Counting Computed Tomography—Part II: Clinical Overview of Neurovascular Applications
Photon-counting detector (PCD) is a novel computed tomography detector technology (photon-counting computed tomography—PCCT) that presents many advantages in the neurovascular field, such as increased spatial resolution, reduced radiation exposure, and optimization of the use of contrast agents and...
Autores principales: | , , , , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10253695/ https://www.ncbi.nlm.nih.gov/pubmed/37297821 http://dx.doi.org/10.3390/jcm12113626 |
_version_ | 1785056467459506176 |
---|---|
author | Cademartiri, Filippo Meloni, Antonella Pistoia, Laura Degiorgi, Giulia Clemente, Alberto De Gori, Carmelo Positano, Vincenzo Celi, Simona Berti, Sergio Emdin, Michele Panetta, Daniele Menichetti, Luca Punzo, Bruna Cavaliere, Carlo Bossone, Eduardo Saba, Luca Cau, Riccardo Grutta, Ludovico La Maffei, Erica |
author_facet | Cademartiri, Filippo Meloni, Antonella Pistoia, Laura Degiorgi, Giulia Clemente, Alberto De Gori, Carmelo Positano, Vincenzo Celi, Simona Berti, Sergio Emdin, Michele Panetta, Daniele Menichetti, Luca Punzo, Bruna Cavaliere, Carlo Bossone, Eduardo Saba, Luca Cau, Riccardo Grutta, Ludovico La Maffei, Erica |
author_sort | Cademartiri, Filippo |
collection | PubMed |
description | Photon-counting detector (PCD) is a novel computed tomography detector technology (photon-counting computed tomography—PCCT) that presents many advantages in the neurovascular field, such as increased spatial resolution, reduced radiation exposure, and optimization of the use of contrast agents and material decomposition. In this overview of the existing literature on PCCT, we describe the physical principles, the advantages and the disadvantages of conventional energy integrating detectors and PCDs, and finally, we discuss the applications of the PCD, focusing specifically on its implementation in the neurovascular field. |
format | Online Article Text |
id | pubmed-10253695 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-102536952023-06-10 Dual Source Photon-Counting Computed Tomography—Part II: Clinical Overview of Neurovascular Applications Cademartiri, Filippo Meloni, Antonella Pistoia, Laura Degiorgi, Giulia Clemente, Alberto De Gori, Carmelo Positano, Vincenzo Celi, Simona Berti, Sergio Emdin, Michele Panetta, Daniele Menichetti, Luca Punzo, Bruna Cavaliere, Carlo Bossone, Eduardo Saba, Luca Cau, Riccardo Grutta, Ludovico La Maffei, Erica J Clin Med Review Photon-counting detector (PCD) is a novel computed tomography detector technology (photon-counting computed tomography—PCCT) that presents many advantages in the neurovascular field, such as increased spatial resolution, reduced radiation exposure, and optimization of the use of contrast agents and material decomposition. In this overview of the existing literature on PCCT, we describe the physical principles, the advantages and the disadvantages of conventional energy integrating detectors and PCDs, and finally, we discuss the applications of the PCD, focusing specifically on its implementation in the neurovascular field. MDPI 2023-05-23 /pmc/articles/PMC10253695/ /pubmed/37297821 http://dx.doi.org/10.3390/jcm12113626 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Review Cademartiri, Filippo Meloni, Antonella Pistoia, Laura Degiorgi, Giulia Clemente, Alberto De Gori, Carmelo Positano, Vincenzo Celi, Simona Berti, Sergio Emdin, Michele Panetta, Daniele Menichetti, Luca Punzo, Bruna Cavaliere, Carlo Bossone, Eduardo Saba, Luca Cau, Riccardo Grutta, Ludovico La Maffei, Erica Dual Source Photon-Counting Computed Tomography—Part II: Clinical Overview of Neurovascular Applications |
title | Dual Source Photon-Counting Computed Tomography—Part II: Clinical Overview of Neurovascular Applications |
title_full | Dual Source Photon-Counting Computed Tomography—Part II: Clinical Overview of Neurovascular Applications |
title_fullStr | Dual Source Photon-Counting Computed Tomography—Part II: Clinical Overview of Neurovascular Applications |
title_full_unstemmed | Dual Source Photon-Counting Computed Tomography—Part II: Clinical Overview of Neurovascular Applications |
title_short | Dual Source Photon-Counting Computed Tomography—Part II: Clinical Overview of Neurovascular Applications |
title_sort | dual source photon-counting computed tomography—part ii: clinical overview of neurovascular applications |
topic | Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10253695/ https://www.ncbi.nlm.nih.gov/pubmed/37297821 http://dx.doi.org/10.3390/jcm12113626 |
work_keys_str_mv | AT cademartirifilippo dualsourcephotoncountingcomputedtomographypartiiclinicaloverviewofneurovascularapplications AT meloniantonella dualsourcephotoncountingcomputedtomographypartiiclinicaloverviewofneurovascularapplications AT pistoialaura dualsourcephotoncountingcomputedtomographypartiiclinicaloverviewofneurovascularapplications AT degiorgigiulia dualsourcephotoncountingcomputedtomographypartiiclinicaloverviewofneurovascularapplications AT clementealberto dualsourcephotoncountingcomputedtomographypartiiclinicaloverviewofneurovascularapplications AT degoricarmelo dualsourcephotoncountingcomputedtomographypartiiclinicaloverviewofneurovascularapplications AT positanovincenzo dualsourcephotoncountingcomputedtomographypartiiclinicaloverviewofneurovascularapplications AT celisimona dualsourcephotoncountingcomputedtomographypartiiclinicaloverviewofneurovascularapplications AT bertisergio dualsourcephotoncountingcomputedtomographypartiiclinicaloverviewofneurovascularapplications AT emdinmichele dualsourcephotoncountingcomputedtomographypartiiclinicaloverviewofneurovascularapplications AT panettadaniele dualsourcephotoncountingcomputedtomographypartiiclinicaloverviewofneurovascularapplications AT menichettiluca dualsourcephotoncountingcomputedtomographypartiiclinicaloverviewofneurovascularapplications AT punzobruna dualsourcephotoncountingcomputedtomographypartiiclinicaloverviewofneurovascularapplications AT cavalierecarlo dualsourcephotoncountingcomputedtomographypartiiclinicaloverviewofneurovascularapplications AT bossoneeduardo dualsourcephotoncountingcomputedtomographypartiiclinicaloverviewofneurovascularapplications AT sabaluca dualsourcephotoncountingcomputedtomographypartiiclinicaloverviewofneurovascularapplications AT cauriccardo dualsourcephotoncountingcomputedtomographypartiiclinicaloverviewofneurovascularapplications AT gruttaludovicola dualsourcephotoncountingcomputedtomographypartiiclinicaloverviewofneurovascularapplications AT maffeierica dualsourcephotoncountingcomputedtomographypartiiclinicaloverviewofneurovascularapplications |