Cargando…

Normative Topographic Anterior and Posterior Corneal Astigmatism: Axis Distribution and Its Relations with Ocular and Biometric Parameters

Corneal astigmatism correction is a key factor when planning refractive treatment for ametropies with intraocular lenses. We aim to obtain normative anterior and posterior corneal astigmatism (ACA and PCA, respectively) data in a local population and to describe their axis distribution and their ass...

Descripción completa

Detalles Bibliográficos
Autores principales: Almorín-Fernández-Vigo, Ignacio, Sánchez-Guillén, Inés, Fernández-Vigo, José Ignacio, Burgos-Blasco, Bárbara, De-Pablo-Gómez-de-Liaño, Lucía, Fernández-Vigo, José Ángel, Macarro-Merino, Ana
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10253972/
https://www.ncbi.nlm.nih.gov/pubmed/37297859
http://dx.doi.org/10.3390/jcm12113664
_version_ 1785056533257650176
author Almorín-Fernández-Vigo, Ignacio
Sánchez-Guillén, Inés
Fernández-Vigo, José Ignacio
Burgos-Blasco, Bárbara
De-Pablo-Gómez-de-Liaño, Lucía
Fernández-Vigo, José Ángel
Macarro-Merino, Ana
author_facet Almorín-Fernández-Vigo, Ignacio
Sánchez-Guillén, Inés
Fernández-Vigo, José Ignacio
Burgos-Blasco, Bárbara
De-Pablo-Gómez-de-Liaño, Lucía
Fernández-Vigo, José Ángel
Macarro-Merino, Ana
author_sort Almorín-Fernández-Vigo, Ignacio
collection PubMed
description Corneal astigmatism correction is a key factor when planning refractive treatment for ametropies with intraocular lenses. We aim to obtain normative anterior and posterior corneal astigmatism (ACA and PCA, respectively) data in a local population and to describe their axis distribution and their association with other parameters. A total of 795 patients with no ocular diseases were evaluated with corneal tomography and optical biometry. Only data of the right eye were included. Mean ACA and PCA were 1.01 ± 0.79 and 0.34 ± 0.17 D, respectively. Vertical steep axis distribution was 73.5% for ACA and 93.3% for PCA. Axis orientation between ACA and PCA matched best for vertical orientation (especially 90° to 120°). Vertical ACA orientation frequency decreased with age, with a more positive sphere and less ACA. Vertical PCA orientation frequency increased with higher PCA. Eyes with vertical ACA orientation were younger and showed a greater white-to-white (WTW) measurement, anterior corneal elevations, ACA and PCA. Eyes with vertical PCA orientation were younger and showed greater anterior corneal elevations and PCA. Normative ACA and PCA data in a Spanish population were presented. Steep axis orientations presented differences with age, WTW, anterior corneal elevations and astigmatism.
format Online
Article
Text
id pubmed-10253972
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-102539722023-06-10 Normative Topographic Anterior and Posterior Corneal Astigmatism: Axis Distribution and Its Relations with Ocular and Biometric Parameters Almorín-Fernández-Vigo, Ignacio Sánchez-Guillén, Inés Fernández-Vigo, José Ignacio Burgos-Blasco, Bárbara De-Pablo-Gómez-de-Liaño, Lucía Fernández-Vigo, José Ángel Macarro-Merino, Ana J Clin Med Article Corneal astigmatism correction is a key factor when planning refractive treatment for ametropies with intraocular lenses. We aim to obtain normative anterior and posterior corneal astigmatism (ACA and PCA, respectively) data in a local population and to describe their axis distribution and their association with other parameters. A total of 795 patients with no ocular diseases were evaluated with corneal tomography and optical biometry. Only data of the right eye were included. Mean ACA and PCA were 1.01 ± 0.79 and 0.34 ± 0.17 D, respectively. Vertical steep axis distribution was 73.5% for ACA and 93.3% for PCA. Axis orientation between ACA and PCA matched best for vertical orientation (especially 90° to 120°). Vertical ACA orientation frequency decreased with age, with a more positive sphere and less ACA. Vertical PCA orientation frequency increased with higher PCA. Eyes with vertical ACA orientation were younger and showed a greater white-to-white (WTW) measurement, anterior corneal elevations, ACA and PCA. Eyes with vertical PCA orientation were younger and showed greater anterior corneal elevations and PCA. Normative ACA and PCA data in a Spanish population were presented. Steep axis orientations presented differences with age, WTW, anterior corneal elevations and astigmatism. MDPI 2023-05-25 /pmc/articles/PMC10253972/ /pubmed/37297859 http://dx.doi.org/10.3390/jcm12113664 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Almorín-Fernández-Vigo, Ignacio
Sánchez-Guillén, Inés
Fernández-Vigo, José Ignacio
Burgos-Blasco, Bárbara
De-Pablo-Gómez-de-Liaño, Lucía
Fernández-Vigo, José Ángel
Macarro-Merino, Ana
Normative Topographic Anterior and Posterior Corneal Astigmatism: Axis Distribution and Its Relations with Ocular and Biometric Parameters
title Normative Topographic Anterior and Posterior Corneal Astigmatism: Axis Distribution and Its Relations with Ocular and Biometric Parameters
title_full Normative Topographic Anterior and Posterior Corneal Astigmatism: Axis Distribution and Its Relations with Ocular and Biometric Parameters
title_fullStr Normative Topographic Anterior and Posterior Corneal Astigmatism: Axis Distribution and Its Relations with Ocular and Biometric Parameters
title_full_unstemmed Normative Topographic Anterior and Posterior Corneal Astigmatism: Axis Distribution and Its Relations with Ocular and Biometric Parameters
title_short Normative Topographic Anterior and Posterior Corneal Astigmatism: Axis Distribution and Its Relations with Ocular and Biometric Parameters
title_sort normative topographic anterior and posterior corneal astigmatism: axis distribution and its relations with ocular and biometric parameters
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10253972/
https://www.ncbi.nlm.nih.gov/pubmed/37297859
http://dx.doi.org/10.3390/jcm12113664
work_keys_str_mv AT almorinfernandezvigoignacio normativetopographicanteriorandposteriorcornealastigmatismaxisdistributionanditsrelationswithocularandbiometricparameters
AT sanchezguillenines normativetopographicanteriorandposteriorcornealastigmatismaxisdistributionanditsrelationswithocularandbiometricparameters
AT fernandezvigojoseignacio normativetopographicanteriorandposteriorcornealastigmatismaxisdistributionanditsrelationswithocularandbiometricparameters
AT burgosblascobarbara normativetopographicanteriorandposteriorcornealastigmatismaxisdistributionanditsrelationswithocularandbiometricparameters
AT depablogomezdelianolucia normativetopographicanteriorandposteriorcornealastigmatismaxisdistributionanditsrelationswithocularandbiometricparameters
AT fernandezvigojoseangel normativetopographicanteriorandposteriorcornealastigmatismaxisdistributionanditsrelationswithocularandbiometricparameters
AT macarromerinoana normativetopographicanteriorandposteriorcornealastigmatismaxisdistributionanditsrelationswithocularandbiometricparameters