Cargando…
Off-pump injectable versus on-pump conventional tissue valves for pulmonary valve replacement: the injectable valve implantation randomised trial (INVITE)
OBJECTIVES: To assess the effectiveness of injectable tissue pulmonary valve compared with standard pulmonary valve in patients requiring pulmonary valve replacement surgery. DESIGN: A multicentre, single-blind, parallel two-group randomised controlled trial. Participants were blind to their allocat...
Autores principales: | , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BMJ Publishing Group
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10254783/ https://www.ncbi.nlm.nih.gov/pubmed/37263697 http://dx.doi.org/10.1136/bmjopen-2022-065192 |
_version_ | 1785056723991527424 |
---|---|
author | Heys, Rachael Walker-Smith, Terrie Evans, Rebecca Caputo, Massimo Culliford, Lucy Reeves, Barnaby Rogers, Chris Turner, Mark Hamilton, Mark Sheehan, Karen Viola, Nicola Stoica, Serban Wright, Kim Angelini, Gianni Parry, Andrew |
author_facet | Heys, Rachael Walker-Smith, Terrie Evans, Rebecca Caputo, Massimo Culliford, Lucy Reeves, Barnaby Rogers, Chris Turner, Mark Hamilton, Mark Sheehan, Karen Viola, Nicola Stoica, Serban Wright, Kim Angelini, Gianni Parry, Andrew |
author_sort | Heys, Rachael |
collection | PubMed |
description | OBJECTIVES: To assess the effectiveness of injectable tissue pulmonary valve compared with standard pulmonary valve in patients requiring pulmonary valve replacement surgery. DESIGN: A multicentre, single-blind, parallel two-group randomised controlled trial. Participants were blind to their allocation. Follow-up continued for 6 months. Randomised allocations were generated by a computer using block randomisation, stratified by centre. SETTING: Two National Health Service secondary care centres in the UK. PARTICIPANTS: People aged 12–80 years requiring pulmonary valve replacement. INTERVENTIONS: Participants were randomly allocated (1:1 ratio) to injectable pulmonary valve replacement (IPVR) without cardiopulmonary bypass (CPB) or standard pulmonary valve replacement (SPVR) with CPB. PRIMARY AND SECONDARY OUTCOME MEASURES: The primary outcome was chest drainage volume over the first 24 hours after surgery. Secondary outcomes included in-hospital clinical outcomes; valve and heart function 6 months postsurgery and health-related quality of life 6 weeks and 6 months postsurgery. RESULTS: Nineteen participants agreed to take part. Eleven were allocated to IPVR and eight to SPVR. The trial was stopped before the target sample size of 60 participants was reached due to challenges in recruitment. The primary analysis includes all randomised participants; there were no withdrawals. Chest drain volume 24 hours after surgery was on average 277.6 mL lower with IPVR (IPVR mean 340.0 mL; SPVR mean 633.8 mL; mean difference, −277.6; 95% CI, −484.0 to −71.2; p=0.005). There were no statistically significant differences in time to readiness for extubation (p=0.476), time to fitness for discharge (p=0.577) and time to first discharge from the intensive care unit (p=0.209). Six participants with IPVR required CPB. Safety profiles and quality of life scores were similar. CONCLUSIONS: IPVR reduced chest drain volume despite >50% of participants requiring CPB. There was no evidence of any other benefit of IPVR. TRIAL REGISTRATION NUMBER: ISRCTN23538073. |
format | Online Article Text |
id | pubmed-10254783 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BMJ Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-102547832023-06-10 Off-pump injectable versus on-pump conventional tissue valves for pulmonary valve replacement: the injectable valve implantation randomised trial (INVITE) Heys, Rachael Walker-Smith, Terrie Evans, Rebecca Caputo, Massimo Culliford, Lucy Reeves, Barnaby Rogers, Chris Turner, Mark Hamilton, Mark Sheehan, Karen Viola, Nicola Stoica, Serban Wright, Kim Angelini, Gianni Parry, Andrew BMJ Open Cardiovascular Medicine OBJECTIVES: To assess the effectiveness of injectable tissue pulmonary valve compared with standard pulmonary valve in patients requiring pulmonary valve replacement surgery. DESIGN: A multicentre, single-blind, parallel two-group randomised controlled trial. Participants were blind to their allocation. Follow-up continued for 6 months. Randomised allocations were generated by a computer using block randomisation, stratified by centre. SETTING: Two National Health Service secondary care centres in the UK. PARTICIPANTS: People aged 12–80 years requiring pulmonary valve replacement. INTERVENTIONS: Participants were randomly allocated (1:1 ratio) to injectable pulmonary valve replacement (IPVR) without cardiopulmonary bypass (CPB) or standard pulmonary valve replacement (SPVR) with CPB. PRIMARY AND SECONDARY OUTCOME MEASURES: The primary outcome was chest drainage volume over the first 24 hours after surgery. Secondary outcomes included in-hospital clinical outcomes; valve and heart function 6 months postsurgery and health-related quality of life 6 weeks and 6 months postsurgery. RESULTS: Nineteen participants agreed to take part. Eleven were allocated to IPVR and eight to SPVR. The trial was stopped before the target sample size of 60 participants was reached due to challenges in recruitment. The primary analysis includes all randomised participants; there were no withdrawals. Chest drain volume 24 hours after surgery was on average 277.6 mL lower with IPVR (IPVR mean 340.0 mL; SPVR mean 633.8 mL; mean difference, −277.6; 95% CI, −484.0 to −71.2; p=0.005). There were no statistically significant differences in time to readiness for extubation (p=0.476), time to fitness for discharge (p=0.577) and time to first discharge from the intensive care unit (p=0.209). Six participants with IPVR required CPB. Safety profiles and quality of life scores were similar. CONCLUSIONS: IPVR reduced chest drain volume despite >50% of participants requiring CPB. There was no evidence of any other benefit of IPVR. TRIAL REGISTRATION NUMBER: ISRCTN23538073. BMJ Publishing Group 2023-06-01 /pmc/articles/PMC10254783/ /pubmed/37263697 http://dx.doi.org/10.1136/bmjopen-2022-065192 Text en © Author(s) (or their employer(s)) 2023. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. https://creativecommons.org/licenses/by-nc/4.0/This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) . |
spellingShingle | Cardiovascular Medicine Heys, Rachael Walker-Smith, Terrie Evans, Rebecca Caputo, Massimo Culliford, Lucy Reeves, Barnaby Rogers, Chris Turner, Mark Hamilton, Mark Sheehan, Karen Viola, Nicola Stoica, Serban Wright, Kim Angelini, Gianni Parry, Andrew Off-pump injectable versus on-pump conventional tissue valves for pulmonary valve replacement: the injectable valve implantation randomised trial (INVITE) |
title | Off-pump injectable versus on-pump conventional tissue valves for pulmonary valve replacement: the injectable valve implantation randomised trial (INVITE) |
title_full | Off-pump injectable versus on-pump conventional tissue valves for pulmonary valve replacement: the injectable valve implantation randomised trial (INVITE) |
title_fullStr | Off-pump injectable versus on-pump conventional tissue valves for pulmonary valve replacement: the injectable valve implantation randomised trial (INVITE) |
title_full_unstemmed | Off-pump injectable versus on-pump conventional tissue valves for pulmonary valve replacement: the injectable valve implantation randomised trial (INVITE) |
title_short | Off-pump injectable versus on-pump conventional tissue valves for pulmonary valve replacement: the injectable valve implantation randomised trial (INVITE) |
title_sort | off-pump injectable versus on-pump conventional tissue valves for pulmonary valve replacement: the injectable valve implantation randomised trial (invite) |
topic | Cardiovascular Medicine |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10254783/ https://www.ncbi.nlm.nih.gov/pubmed/37263697 http://dx.doi.org/10.1136/bmjopen-2022-065192 |
work_keys_str_mv | AT heysrachael offpumpinjectableversusonpumpconventionaltissuevalvesforpulmonaryvalvereplacementtheinjectablevalveimplantationrandomisedtrialinvite AT walkersmithterrie offpumpinjectableversusonpumpconventionaltissuevalvesforpulmonaryvalvereplacementtheinjectablevalveimplantationrandomisedtrialinvite AT evansrebecca offpumpinjectableversusonpumpconventionaltissuevalvesforpulmonaryvalvereplacementtheinjectablevalveimplantationrandomisedtrialinvite AT caputomassimo offpumpinjectableversusonpumpconventionaltissuevalvesforpulmonaryvalvereplacementtheinjectablevalveimplantationrandomisedtrialinvite AT cullifordlucy offpumpinjectableversusonpumpconventionaltissuevalvesforpulmonaryvalvereplacementtheinjectablevalveimplantationrandomisedtrialinvite AT reevesbarnaby offpumpinjectableversusonpumpconventionaltissuevalvesforpulmonaryvalvereplacementtheinjectablevalveimplantationrandomisedtrialinvite AT rogerschris offpumpinjectableversusonpumpconventionaltissuevalvesforpulmonaryvalvereplacementtheinjectablevalveimplantationrandomisedtrialinvite AT turnermark offpumpinjectableversusonpumpconventionaltissuevalvesforpulmonaryvalvereplacementtheinjectablevalveimplantationrandomisedtrialinvite AT hamiltonmark offpumpinjectableversusonpumpconventionaltissuevalvesforpulmonaryvalvereplacementtheinjectablevalveimplantationrandomisedtrialinvite AT sheehankaren offpumpinjectableversusonpumpconventionaltissuevalvesforpulmonaryvalvereplacementtheinjectablevalveimplantationrandomisedtrialinvite AT violanicola offpumpinjectableversusonpumpconventionaltissuevalvesforpulmonaryvalvereplacementtheinjectablevalveimplantationrandomisedtrialinvite AT stoicaserban offpumpinjectableversusonpumpconventionaltissuevalvesforpulmonaryvalvereplacementtheinjectablevalveimplantationrandomisedtrialinvite AT wrightkim offpumpinjectableversusonpumpconventionaltissuevalvesforpulmonaryvalvereplacementtheinjectablevalveimplantationrandomisedtrialinvite AT angelinigianni offpumpinjectableversusonpumpconventionaltissuevalvesforpulmonaryvalvereplacementtheinjectablevalveimplantationrandomisedtrialinvite AT parryandrew offpumpinjectableversusonpumpconventionaltissuevalvesforpulmonaryvalvereplacementtheinjectablevalveimplantationrandomisedtrialinvite |