Cargando…

Diabetic Retinopathy Screening Using Non-Mydriatic Fundus Camera in Primary Health Care Settings – A Multicenter Study from Saudi Arabia

BACKGROUND: Screening of diabetic retinopathy (DR) using the current digital imaging facilities in a primary health care setting is still in its early stages in Saudi Arabia. This study aims to reduce the risk of vision impairment and blindness among known diabetic people through early identificatio...

Descripción completa

Detalles Bibliográficos
Autor principal: Alabdulwahhab, Khalid Mohammad
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10255608/
https://www.ncbi.nlm.nih.gov/pubmed/37304902
http://dx.doi.org/10.2147/IJGM.S410197
_version_ 1785056913083334656
author Alabdulwahhab, Khalid Mohammad
author_facet Alabdulwahhab, Khalid Mohammad
author_sort Alabdulwahhab, Khalid Mohammad
collection PubMed
description BACKGROUND: Screening of diabetic retinopathy (DR) using the current digital imaging facilities in a primary health care setting is still in its early stages in Saudi Arabia. This study aims to reduce the risk of vision impairment and blindness among known diabetic people through early identification by general practitioners (GP) in a primary health care setting in Saudi Arabia. The objective of this study was to evaluate the accuracy of diabetic retinopathy (DR) detection by general practitioners (GPs) by comparing the agreement of DR assessment between GPs and ophthalmologists' assessment as a gold standard. METHODS: A hospital-based, six-month cross-sectional study was conducted, and the participants were type 2 diabetic adults from the diabetic registries of seven rural PHCs, in Saudi Arabia. After medical examination, the participants were then evaluated by fundus photography using a non-mydriatic fundus camera without medication for mydriasis. Presence or absence of DR was graded by the trained GPs in the PHCs and then compared with the grading of an ophthalmologist which was taken as a reference or a gold standard. RESULTS: A total of 899 diabetic patients were included, and the mean age of the patients was 64.89 ± 11.01 years. The evaluation by the GPs had a sensitivity of 80.69 [95% CI 74.8–85.4]; specificity of 92.23 [88.7–96.3]; positive predictive value, 74.1 [70.4–77.0]; negative predictive value, 73.34 [70.6–77.9]; and an accuracy of 84.57 [81.8–89.88]. For the consensus of agreement the adjusted kappa coefficient was from 0.74 to 0.92 for the DR. CONCLUSION: This study demonstrates that trained GPs in rural health centers are able to provide reliable detection results of DR from fundus photographs. The study highlights the need for early DR screening programs in the rural areas of Saudi Arabia to facilitate early identification of the condition and to lessen impact of blindness due to diabetes.
format Online
Article
Text
id pubmed-10255608
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Dove
record_format MEDLINE/PubMed
spelling pubmed-102556082023-06-10 Diabetic Retinopathy Screening Using Non-Mydriatic Fundus Camera in Primary Health Care Settings – A Multicenter Study from Saudi Arabia Alabdulwahhab, Khalid Mohammad Int J Gen Med Original Research BACKGROUND: Screening of diabetic retinopathy (DR) using the current digital imaging facilities in a primary health care setting is still in its early stages in Saudi Arabia. This study aims to reduce the risk of vision impairment and blindness among known diabetic people through early identification by general practitioners (GP) in a primary health care setting in Saudi Arabia. The objective of this study was to evaluate the accuracy of diabetic retinopathy (DR) detection by general practitioners (GPs) by comparing the agreement of DR assessment between GPs and ophthalmologists' assessment as a gold standard. METHODS: A hospital-based, six-month cross-sectional study was conducted, and the participants were type 2 diabetic adults from the diabetic registries of seven rural PHCs, in Saudi Arabia. After medical examination, the participants were then evaluated by fundus photography using a non-mydriatic fundus camera without medication for mydriasis. Presence or absence of DR was graded by the trained GPs in the PHCs and then compared with the grading of an ophthalmologist which was taken as a reference or a gold standard. RESULTS: A total of 899 diabetic patients were included, and the mean age of the patients was 64.89 ± 11.01 years. The evaluation by the GPs had a sensitivity of 80.69 [95% CI 74.8–85.4]; specificity of 92.23 [88.7–96.3]; positive predictive value, 74.1 [70.4–77.0]; negative predictive value, 73.34 [70.6–77.9]; and an accuracy of 84.57 [81.8–89.88]. For the consensus of agreement the adjusted kappa coefficient was from 0.74 to 0.92 for the DR. CONCLUSION: This study demonstrates that trained GPs in rural health centers are able to provide reliable detection results of DR from fundus photographs. The study highlights the need for early DR screening programs in the rural areas of Saudi Arabia to facilitate early identification of the condition and to lessen impact of blindness due to diabetes. Dove 2023-06-05 /pmc/articles/PMC10255608/ /pubmed/37304902 http://dx.doi.org/10.2147/IJGM.S410197 Text en © 2023 Alabdulwahhab. https://creativecommons.org/licenses/by-nc/3.0/This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).
spellingShingle Original Research
Alabdulwahhab, Khalid Mohammad
Diabetic Retinopathy Screening Using Non-Mydriatic Fundus Camera in Primary Health Care Settings – A Multicenter Study from Saudi Arabia
title Diabetic Retinopathy Screening Using Non-Mydriatic Fundus Camera in Primary Health Care Settings – A Multicenter Study from Saudi Arabia
title_full Diabetic Retinopathy Screening Using Non-Mydriatic Fundus Camera in Primary Health Care Settings – A Multicenter Study from Saudi Arabia
title_fullStr Diabetic Retinopathy Screening Using Non-Mydriatic Fundus Camera in Primary Health Care Settings – A Multicenter Study from Saudi Arabia
title_full_unstemmed Diabetic Retinopathy Screening Using Non-Mydriatic Fundus Camera in Primary Health Care Settings – A Multicenter Study from Saudi Arabia
title_short Diabetic Retinopathy Screening Using Non-Mydriatic Fundus Camera in Primary Health Care Settings – A Multicenter Study from Saudi Arabia
title_sort diabetic retinopathy screening using non-mydriatic fundus camera in primary health care settings – a multicenter study from saudi arabia
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10255608/
https://www.ncbi.nlm.nih.gov/pubmed/37304902
http://dx.doi.org/10.2147/IJGM.S410197
work_keys_str_mv AT alabdulwahhabkhalidmohammad diabeticretinopathyscreeningusingnonmydriaticfunduscamerainprimaryhealthcaresettingsamulticenterstudyfromsaudiarabia