Cargando…

A Microstrip Transmission Line Biosensor to Measure the Interaction between Microliter Aqueous Solutions and 1.0–17.0 GHz Radio Frequencies

Radio frequency (RF) biosensors are an expanding field of interest because of the ability to design noninvasive, label-free, low-production-cost sensing devices. Previous works identified the need for smaller experimental devices, requiring nanoliter to milliliter sampling volumes and increased capa...

Descripción completa

Detalles Bibliográficos
Autores principales: Godfrey, Mary, Ewert, Daniel, Striker, Ryan, Braaten, Benjamin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10255756/
https://www.ncbi.nlm.nih.gov/pubmed/37299920
http://dx.doi.org/10.3390/s23115193
_version_ 1785056949408104448
author Godfrey, Mary
Ewert, Daniel
Striker, Ryan
Braaten, Benjamin
author_facet Godfrey, Mary
Ewert, Daniel
Striker, Ryan
Braaten, Benjamin
author_sort Godfrey, Mary
collection PubMed
description Radio frequency (RF) biosensors are an expanding field of interest because of the ability to design noninvasive, label-free, low-production-cost sensing devices. Previous works identified the need for smaller experimental devices, requiring nanoliter to milliliter sampling volumes and increased capability of repeatable and sensitive measurement capability. The following work aims to verify a millimeter-sized, microstrip transmission line biosensor design with a microliter well operating on a broadband radio frequency range of 1.0–17.0 GHz. Three successive experiments were performed to provide evidence for (1) repeatability of measurements after loading/unloading the well, (2) sensitivity of measurement sets, and (3) methodology verification. Materials under test (MUTs) loaded into the well included deionized water, Tris-EDTA buffer, and lambda DNA. S-parameters were measured to determine interaction levels between the radio frequencies and MUTs during the broadband sweep. MUTs increasing in concentration were repeatably detected and demonstrated high measurement sensitivity, with the highest error value observed being 0.36%. Comparing Tris-EDTA buffer versus lambda DNA suspended in Tris-EDTA buffer suggests that introducing lambda DNA into the Tris-EDTA buffer repeatably alters S-parameters. The innovative aspect of this biosensor is that it can measure interactions of electromagnetic energy and MUTs in microliter quantities with high repeatability and sensitivity.
format Online
Article
Text
id pubmed-10255756
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-102557562023-06-10 A Microstrip Transmission Line Biosensor to Measure the Interaction between Microliter Aqueous Solutions and 1.0–17.0 GHz Radio Frequencies Godfrey, Mary Ewert, Daniel Striker, Ryan Braaten, Benjamin Sensors (Basel) Article Radio frequency (RF) biosensors are an expanding field of interest because of the ability to design noninvasive, label-free, low-production-cost sensing devices. Previous works identified the need for smaller experimental devices, requiring nanoliter to milliliter sampling volumes and increased capability of repeatable and sensitive measurement capability. The following work aims to verify a millimeter-sized, microstrip transmission line biosensor design with a microliter well operating on a broadband radio frequency range of 1.0–17.0 GHz. Three successive experiments were performed to provide evidence for (1) repeatability of measurements after loading/unloading the well, (2) sensitivity of measurement sets, and (3) methodology verification. Materials under test (MUTs) loaded into the well included deionized water, Tris-EDTA buffer, and lambda DNA. S-parameters were measured to determine interaction levels between the radio frequencies and MUTs during the broadband sweep. MUTs increasing in concentration were repeatably detected and demonstrated high measurement sensitivity, with the highest error value observed being 0.36%. Comparing Tris-EDTA buffer versus lambda DNA suspended in Tris-EDTA buffer suggests that introducing lambda DNA into the Tris-EDTA buffer repeatably alters S-parameters. The innovative aspect of this biosensor is that it can measure interactions of electromagnetic energy and MUTs in microliter quantities with high repeatability and sensitivity. MDPI 2023-05-30 /pmc/articles/PMC10255756/ /pubmed/37299920 http://dx.doi.org/10.3390/s23115193 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Godfrey, Mary
Ewert, Daniel
Striker, Ryan
Braaten, Benjamin
A Microstrip Transmission Line Biosensor to Measure the Interaction between Microliter Aqueous Solutions and 1.0–17.0 GHz Radio Frequencies
title A Microstrip Transmission Line Biosensor to Measure the Interaction between Microliter Aqueous Solutions and 1.0–17.0 GHz Radio Frequencies
title_full A Microstrip Transmission Line Biosensor to Measure the Interaction between Microliter Aqueous Solutions and 1.0–17.0 GHz Radio Frequencies
title_fullStr A Microstrip Transmission Line Biosensor to Measure the Interaction between Microliter Aqueous Solutions and 1.0–17.0 GHz Radio Frequencies
title_full_unstemmed A Microstrip Transmission Line Biosensor to Measure the Interaction between Microliter Aqueous Solutions and 1.0–17.0 GHz Radio Frequencies
title_short A Microstrip Transmission Line Biosensor to Measure the Interaction between Microliter Aqueous Solutions and 1.0–17.0 GHz Radio Frequencies
title_sort microstrip transmission line biosensor to measure the interaction between microliter aqueous solutions and 1.0–17.0 ghz radio frequencies
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10255756/
https://www.ncbi.nlm.nih.gov/pubmed/37299920
http://dx.doi.org/10.3390/s23115193
work_keys_str_mv AT godfreymary amicrostriptransmissionlinebiosensortomeasuretheinteractionbetweenmicroliteraqueoussolutionsand10170ghzradiofrequencies
AT ewertdaniel amicrostriptransmissionlinebiosensortomeasuretheinteractionbetweenmicroliteraqueoussolutionsand10170ghzradiofrequencies
AT strikerryan amicrostriptransmissionlinebiosensortomeasuretheinteractionbetweenmicroliteraqueoussolutionsand10170ghzradiofrequencies
AT braatenbenjamin amicrostriptransmissionlinebiosensortomeasuretheinteractionbetweenmicroliteraqueoussolutionsand10170ghzradiofrequencies
AT godfreymary microstriptransmissionlinebiosensortomeasuretheinteractionbetweenmicroliteraqueoussolutionsand10170ghzradiofrequencies
AT ewertdaniel microstriptransmissionlinebiosensortomeasuretheinteractionbetweenmicroliteraqueoussolutionsand10170ghzradiofrequencies
AT strikerryan microstriptransmissionlinebiosensortomeasuretheinteractionbetweenmicroliteraqueoussolutionsand10170ghzradiofrequencies
AT braatenbenjamin microstriptransmissionlinebiosensortomeasuretheinteractionbetweenmicroliteraqueoussolutionsand10170ghzradiofrequencies