Cargando…
Comparison of Colorado Needle Electrocautery and Traditional Scalpel for Upper Eyelid Blepharoplasty Incision: A Randomized Controlled Trial and Systematic Review
Upper eyelid blepharoplasty is a popular aesthetic surgery. Electrocautery provides a hemostatic benefit for skin incision; however, its effect on scar cosmesis remains unclear, especially in Asian skin types. We aimed to compare the Colorado needle electrocautery pure cutting mode and the tradition...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Lippincott Williams & Wilkins
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10256415/ https://www.ncbi.nlm.nih.gov/pubmed/37305197 http://dx.doi.org/10.1097/GOX.0000000000005045 |
_version_ | 1785057099328258048 |
---|---|
author | Pruksapong, Chatchai Jankajorn, Suttisun Burusapat, Chairat Wanichjaroen, Nutthapong Wongprakob, Nuttadon Techasatian, Peeraya |
author_facet | Pruksapong, Chatchai Jankajorn, Suttisun Burusapat, Chairat Wanichjaroen, Nutthapong Wongprakob, Nuttadon Techasatian, Peeraya |
author_sort | Pruksapong, Chatchai |
collection | PubMed |
description | Upper eyelid blepharoplasty is a popular aesthetic surgery. Electrocautery provides a hemostatic benefit for skin incision; however, its effect on scar cosmesis remains unclear, especially in Asian skin types. We aimed to compare the Colorado needle electrocautery pure cutting mode and the traditional scalpel to determine their efficacy, complications, and cosmetic outcomes. METHODS: A systematic review was performed to review the outcome with the conventional method (scalpel) and other methods in upper blepharoplasty procedures. Further, a prospective intraindividual randomized controlled trial was conducted to compare the efficacy of Colorado needle electrocautery and the scalpel in upper blepharoplasty. Study outcomes included scar quality at different times until 1-year postoperation, bleeding during incision, and postoperative ecchymosis. RESULTS: Five articles met the inclusion criteria for this systematic review. The prospective randomized controlled trial study included 30 patients; the average incisional time on the electrocautery side was significantly longer than that on the scalpel side, and the electrocautery side had less blood loss during incision than the scalpel side (2.4 versus 3.27 using average cotton bud sticks, respectively) (P < 0.001). Hypopigmented scarring occurred more frequently on the scalpel side; however, the difference was not statistically significant. CONCLUSIONS: Colorado needle electrocautery pure cutting mode can be an alternative to traditional scalpel for upper eyelid blepharoplasty skin incision because of long-term scar quality. Electrocautery use has hemostatic benefits, leading to a decrease in bleeding that can obscure the incision site. However, the incision time on the electrocautery side was significantly longer than the scalpel side, which may be owing to an adaptation of surgical technique. |
format | Online Article Text |
id | pubmed-10256415 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Lippincott Williams & Wilkins |
record_format | MEDLINE/PubMed |
spelling | pubmed-102564152023-06-10 Comparison of Colorado Needle Electrocautery and Traditional Scalpel for Upper Eyelid Blepharoplasty Incision: A Randomized Controlled Trial and Systematic Review Pruksapong, Chatchai Jankajorn, Suttisun Burusapat, Chairat Wanichjaroen, Nutthapong Wongprakob, Nuttadon Techasatian, Peeraya Plast Reconstr Surg Glob Open Cosmetic Upper eyelid blepharoplasty is a popular aesthetic surgery. Electrocautery provides a hemostatic benefit for skin incision; however, its effect on scar cosmesis remains unclear, especially in Asian skin types. We aimed to compare the Colorado needle electrocautery pure cutting mode and the traditional scalpel to determine their efficacy, complications, and cosmetic outcomes. METHODS: A systematic review was performed to review the outcome with the conventional method (scalpel) and other methods in upper blepharoplasty procedures. Further, a prospective intraindividual randomized controlled trial was conducted to compare the efficacy of Colorado needle electrocautery and the scalpel in upper blepharoplasty. Study outcomes included scar quality at different times until 1-year postoperation, bleeding during incision, and postoperative ecchymosis. RESULTS: Five articles met the inclusion criteria for this systematic review. The prospective randomized controlled trial study included 30 patients; the average incisional time on the electrocautery side was significantly longer than that on the scalpel side, and the electrocautery side had less blood loss during incision than the scalpel side (2.4 versus 3.27 using average cotton bud sticks, respectively) (P < 0.001). Hypopigmented scarring occurred more frequently on the scalpel side; however, the difference was not statistically significant. CONCLUSIONS: Colorado needle electrocautery pure cutting mode can be an alternative to traditional scalpel for upper eyelid blepharoplasty skin incision because of long-term scar quality. Electrocautery use has hemostatic benefits, leading to a decrease in bleeding that can obscure the incision site. However, the incision time on the electrocautery side was significantly longer than the scalpel side, which may be owing to an adaptation of surgical technique. Lippincott Williams & Wilkins 2023-06-09 /pmc/articles/PMC10256415/ /pubmed/37305197 http://dx.doi.org/10.1097/GOX.0000000000005045 Text en Copyright © 2023 The Authors. Published by Wolters Kluwer Health, Inc. on behalf of The American Society of Plastic Surgeons. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND) (https://creativecommons.org/licenses/by-nc-nd/4.0/) , where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. |
spellingShingle | Cosmetic Pruksapong, Chatchai Jankajorn, Suttisun Burusapat, Chairat Wanichjaroen, Nutthapong Wongprakob, Nuttadon Techasatian, Peeraya Comparison of Colorado Needle Electrocautery and Traditional Scalpel for Upper Eyelid Blepharoplasty Incision: A Randomized Controlled Trial and Systematic Review |
title | Comparison of Colorado Needle Electrocautery and Traditional Scalpel for Upper Eyelid Blepharoplasty Incision: A Randomized Controlled Trial and Systematic Review |
title_full | Comparison of Colorado Needle Electrocautery and Traditional Scalpel for Upper Eyelid Blepharoplasty Incision: A Randomized Controlled Trial and Systematic Review |
title_fullStr | Comparison of Colorado Needle Electrocautery and Traditional Scalpel for Upper Eyelid Blepharoplasty Incision: A Randomized Controlled Trial and Systematic Review |
title_full_unstemmed | Comparison of Colorado Needle Electrocautery and Traditional Scalpel for Upper Eyelid Blepharoplasty Incision: A Randomized Controlled Trial and Systematic Review |
title_short | Comparison of Colorado Needle Electrocautery and Traditional Scalpel for Upper Eyelid Blepharoplasty Incision: A Randomized Controlled Trial and Systematic Review |
title_sort | comparison of colorado needle electrocautery and traditional scalpel for upper eyelid blepharoplasty incision: a randomized controlled trial and systematic review |
topic | Cosmetic |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10256415/ https://www.ncbi.nlm.nih.gov/pubmed/37305197 http://dx.doi.org/10.1097/GOX.0000000000005045 |
work_keys_str_mv | AT pruksapongchatchai comparisonofcoloradoneedleelectrocauteryandtraditionalscalpelforuppereyelidblepharoplastyincisionarandomizedcontrolledtrialandsystematicreview AT jankajornsuttisun comparisonofcoloradoneedleelectrocauteryandtraditionalscalpelforuppereyelidblepharoplastyincisionarandomizedcontrolledtrialandsystematicreview AT burusapatchairat comparisonofcoloradoneedleelectrocauteryandtraditionalscalpelforuppereyelidblepharoplastyincisionarandomizedcontrolledtrialandsystematicreview AT wanichjaroennutthapong comparisonofcoloradoneedleelectrocauteryandtraditionalscalpelforuppereyelidblepharoplastyincisionarandomizedcontrolledtrialandsystematicreview AT wongprakobnuttadon comparisonofcoloradoneedleelectrocauteryandtraditionalscalpelforuppereyelidblepharoplastyincisionarandomizedcontrolledtrialandsystematicreview AT techasatianpeeraya comparisonofcoloradoneedleelectrocauteryandtraditionalscalpelforuppereyelidblepharoplastyincisionarandomizedcontrolledtrialandsystematicreview |