Accuracy of a Standalone Atrial Fibrillation Detection Algorithm Added to a Popular Wristband and Smartwatch: Prospective Diagnostic Accuracy Study
BACKGROUND: Silent paroxysmal atrial fibrillation (AF) may be difficult to diagnose, and AF burden is hard to establish. In contrast to conventional diagnostic devices, photoplethysmography (PPG)–driven smartwatches or wristbands allow for long-term continuous heart rhythm assessment. However, most...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
JMIR Publications
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10257103/ https://www.ncbi.nlm.nih.gov/pubmed/37234033 http://dx.doi.org/10.2196/44642 |
_version_ | 1785057240838832128 |
---|---|
author | Selder, Jasper L Te Kolste, Henryk Jan Twisk, Jos Schijven, Marlies Gielen, Willem Allaart, Cornelis P |
author_facet | Selder, Jasper L Te Kolste, Henryk Jan Twisk, Jos Schijven, Marlies Gielen, Willem Allaart, Cornelis P |
author_sort | Selder, Jasper L |
collection | PubMed |
description | BACKGROUND: Silent paroxysmal atrial fibrillation (AF) may be difficult to diagnose, and AF burden is hard to establish. In contrast to conventional diagnostic devices, photoplethysmography (PPG)–driven smartwatches or wristbands allow for long-term continuous heart rhythm assessment. However, most smartwatches lack an integrated PPG-AF algorithm. Adding a standalone PPG-AF algorithm to these wrist devices might open new possibilities for AF screening and burden assessment. OBJECTIVE: The aim of this study was to assess the accuracy of a well-known standalone PPG-AF detection algorithm added to a popular wristband and smartwatch, with regard to discriminating AF and sinus rhythm, in a group of patients with AF before and after cardioversion (CV). METHODS: Consecutive consenting patients with AF admitted for CV in a large academic hospital in Amsterdam, the Netherlands, were asked to wear a Biostrap wristband or Fitbit Ionic smartwatch with Fibricheck algorithm add-on surrounding the procedure. A set of 1-min PPG measurements and 12-lead reference electrocardiograms was obtained before and after CV. Rhythm assessment by the PPG device-software combination was compared with the 12-lead electrocardiogram. RESULTS: A total of 78 patients were included in the Biostrap-Fibricheck cohort (156 measurement sets) and 73 patients in the Fitbit-Fibricheck cohort (143 measurement sets). Of the measurement sets, 19/156 (12%) and 7/143 (5%), respectively, were not classifiable by the PPG algorithm due to bad quality. The diagnostic performance in terms of sensitivity, specificity, positive predictive value, negative predictive value, and accuracy was 98%, 96%, 96%, 99%, 97%, and 97%, 100%, 100%, 97%, and 99%, respectively, at an AF prevalence of ~50%. CONCLUSIONS: This study demonstrates that the addition of a well-known standalone PPG-AF detection algorithm to a popular PPG smartwatch and wristband without integrated algorithm yields a high accuracy for the detection of AF, with an acceptable unclassifiable rate, in a semicontrolled environment. |
format | Online Article Text |
id | pubmed-10257103 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | JMIR Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-102571032023-06-11 Accuracy of a Standalone Atrial Fibrillation Detection Algorithm Added to a Popular Wristband and Smartwatch: Prospective Diagnostic Accuracy Study Selder, Jasper L Te Kolste, Henryk Jan Twisk, Jos Schijven, Marlies Gielen, Willem Allaart, Cornelis P J Med Internet Res Original Paper BACKGROUND: Silent paroxysmal atrial fibrillation (AF) may be difficult to diagnose, and AF burden is hard to establish. In contrast to conventional diagnostic devices, photoplethysmography (PPG)–driven smartwatches or wristbands allow for long-term continuous heart rhythm assessment. However, most smartwatches lack an integrated PPG-AF algorithm. Adding a standalone PPG-AF algorithm to these wrist devices might open new possibilities for AF screening and burden assessment. OBJECTIVE: The aim of this study was to assess the accuracy of a well-known standalone PPG-AF detection algorithm added to a popular wristband and smartwatch, with regard to discriminating AF and sinus rhythm, in a group of patients with AF before and after cardioversion (CV). METHODS: Consecutive consenting patients with AF admitted for CV in a large academic hospital in Amsterdam, the Netherlands, were asked to wear a Biostrap wristband or Fitbit Ionic smartwatch with Fibricheck algorithm add-on surrounding the procedure. A set of 1-min PPG measurements and 12-lead reference electrocardiograms was obtained before and after CV. Rhythm assessment by the PPG device-software combination was compared with the 12-lead electrocardiogram. RESULTS: A total of 78 patients were included in the Biostrap-Fibricheck cohort (156 measurement sets) and 73 patients in the Fitbit-Fibricheck cohort (143 measurement sets). Of the measurement sets, 19/156 (12%) and 7/143 (5%), respectively, were not classifiable by the PPG algorithm due to bad quality. The diagnostic performance in terms of sensitivity, specificity, positive predictive value, negative predictive value, and accuracy was 98%, 96%, 96%, 99%, 97%, and 97%, 100%, 100%, 97%, and 99%, respectively, at an AF prevalence of ~50%. CONCLUSIONS: This study demonstrates that the addition of a well-known standalone PPG-AF detection algorithm to a popular PPG smartwatch and wristband without integrated algorithm yields a high accuracy for the detection of AF, with an acceptable unclassifiable rate, in a semicontrolled environment. JMIR Publications 2023-05-26 /pmc/articles/PMC10257103/ /pubmed/37234033 http://dx.doi.org/10.2196/44642 Text en ©Jasper L Selder, Henryk Jan Te Kolste, Jos Twisk, Marlies Schijven, Willem Gielen, Cornelis P Allaart. Originally published in the Journal of Medical Internet Research (https://www.jmir.org), 26.05.2023. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in the Journal of Medical Internet Research, is properly cited. The complete bibliographic information, a link to the original publication on https://www.jmir.org/, as well as this copyright and license information must be included. |
spellingShingle | Original Paper Selder, Jasper L Te Kolste, Henryk Jan Twisk, Jos Schijven, Marlies Gielen, Willem Allaart, Cornelis P Accuracy of a Standalone Atrial Fibrillation Detection Algorithm Added to a Popular Wristband and Smartwatch: Prospective Diagnostic Accuracy Study |
title | Accuracy of a Standalone Atrial Fibrillation Detection Algorithm Added to a Popular Wristband and Smartwatch: Prospective Diagnostic Accuracy Study |
title_full | Accuracy of a Standalone Atrial Fibrillation Detection Algorithm Added to a Popular Wristband and Smartwatch: Prospective Diagnostic Accuracy Study |
title_fullStr | Accuracy of a Standalone Atrial Fibrillation Detection Algorithm Added to a Popular Wristband and Smartwatch: Prospective Diagnostic Accuracy Study |
title_full_unstemmed | Accuracy of a Standalone Atrial Fibrillation Detection Algorithm Added to a Popular Wristband and Smartwatch: Prospective Diagnostic Accuracy Study |
title_short | Accuracy of a Standalone Atrial Fibrillation Detection Algorithm Added to a Popular Wristband and Smartwatch: Prospective Diagnostic Accuracy Study |
title_sort | accuracy of a standalone atrial fibrillation detection algorithm added to a popular wristband and smartwatch: prospective diagnostic accuracy study |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10257103/ https://www.ncbi.nlm.nih.gov/pubmed/37234033 http://dx.doi.org/10.2196/44642 |
work_keys_str_mv | AT selderjasperl accuracyofastandaloneatrialfibrillationdetectionalgorithmaddedtoapopularwristbandandsmartwatchprospectivediagnosticaccuracystudy AT tekolstehenrykjan accuracyofastandaloneatrialfibrillationdetectionalgorithmaddedtoapopularwristbandandsmartwatchprospectivediagnosticaccuracystudy AT twiskjos accuracyofastandaloneatrialfibrillationdetectionalgorithmaddedtoapopularwristbandandsmartwatchprospectivediagnosticaccuracystudy AT schijvenmarlies accuracyofastandaloneatrialfibrillationdetectionalgorithmaddedtoapopularwristbandandsmartwatchprospectivediagnosticaccuracystudy AT gielenwillem accuracyofastandaloneatrialfibrillationdetectionalgorithmaddedtoapopularwristbandandsmartwatchprospectivediagnosticaccuracystudy AT allaartcornelisp accuracyofastandaloneatrialfibrillationdetectionalgorithmaddedtoapopularwristbandandsmartwatchprospectivediagnosticaccuracystudy |