Cargando…

Comparison of cranial versus medial minimally invasive plate osteosynthesis applications for the stabilization of simulated radius and ulna fractures in dog cadavers

BACKGROUND: Minimally invasive plate osteosynthesis (MIPO) is an emerging fracture management modality in small animal orthopedics. Although cranial plate application has been consistently advocated when performing radial MIPO, medial plating affords several purported advantages including improved s...

Descripción completa

Detalles Bibliográficos
Autores principales: Lederer, XiaoXiao Jade, Lewis, Daniel Dean
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Faculty of Veterinary Medicine 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10257463/
https://www.ncbi.nlm.nih.gov/pubmed/37304599
http://dx.doi.org/10.5455/OVJ.2023.v13.i5.1
_version_ 1785057307641511936
author Lederer, XiaoXiao Jade
Lewis, Daniel Dean
author_facet Lederer, XiaoXiao Jade
Lewis, Daniel Dean
author_sort Lederer, XiaoXiao Jade
collection PubMed
description BACKGROUND: Minimally invasive plate osteosynthesis (MIPO) is an emerging fracture management modality in small animal orthopedics. Although cranial plate application has been consistently advocated when performing radial MIPO, medial plating affords several purported advantages including improved screw purchase through the wider medial-to-lateral dimension of the radius, the potential to use smaller plates allowing more screws per unit length, and avoidance of extensor tendons which can complicate cranial plate placement in distal diaphyseal or metaphyseal fractures. AIM: To compare cranial versus medial MIPO applications for the stabilization of diaphyseal radius and ulna fractures in dog cadavers. METHODS: Simulated bilateral antebrachial fractures were stabilized with cranial MIPO on one forelimb and medial MIPO on the contralateral limb, facilitated by a two-ring circular fixator construct. Procedure times and ease, number of fluoroscopic images obtained, and post-procedural frontal and sagittal alignment and radial length were compared between plating groups. The ease of construct placement, fracture reduction, radial approach, and plate application, were subjectively scored 1–5 for each procedure. Paired t-tests were performed to identify significant differences (p < 0.05) between the two plating groups. RESULTS: There was no difference in total or incremental procedural times, subjective ease scores, or the number of fluoroscopic images obtained between plating groups. Both plating groups had comparable post-procedural frontal and sagittal plane alignment. There was a significant difference between plating groups for final radial length (p = 0.004) and change in radial length compared to the intact radii, (p = 0.002). Medial-plated radii measured longer than cranial-plated radii. CONCLUSION: The only outcome measure significantly different between plating groups was the post-procedural radial length. The change in length compared to intact radii was <1%, regardless of the plating group, and unlikely to be clinically relevant.
format Online
Article
Text
id pubmed-10257463
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Faculty of Veterinary Medicine
record_format MEDLINE/PubMed
spelling pubmed-102574632023-06-11 Comparison of cranial versus medial minimally invasive plate osteosynthesis applications for the stabilization of simulated radius and ulna fractures in dog cadavers Lederer, XiaoXiao Jade Lewis, Daniel Dean Open Vet J Original Research BACKGROUND: Minimally invasive plate osteosynthesis (MIPO) is an emerging fracture management modality in small animal orthopedics. Although cranial plate application has been consistently advocated when performing radial MIPO, medial plating affords several purported advantages including improved screw purchase through the wider medial-to-lateral dimension of the radius, the potential to use smaller plates allowing more screws per unit length, and avoidance of extensor tendons which can complicate cranial plate placement in distal diaphyseal or metaphyseal fractures. AIM: To compare cranial versus medial MIPO applications for the stabilization of diaphyseal radius and ulna fractures in dog cadavers. METHODS: Simulated bilateral antebrachial fractures were stabilized with cranial MIPO on one forelimb and medial MIPO on the contralateral limb, facilitated by a two-ring circular fixator construct. Procedure times and ease, number of fluoroscopic images obtained, and post-procedural frontal and sagittal alignment and radial length were compared between plating groups. The ease of construct placement, fracture reduction, radial approach, and plate application, were subjectively scored 1–5 for each procedure. Paired t-tests were performed to identify significant differences (p < 0.05) between the two plating groups. RESULTS: There was no difference in total or incremental procedural times, subjective ease scores, or the number of fluoroscopic images obtained between plating groups. Both plating groups had comparable post-procedural frontal and sagittal plane alignment. There was a significant difference between plating groups for final radial length (p = 0.004) and change in radial length compared to the intact radii, (p = 0.002). Medial-plated radii measured longer than cranial-plated radii. CONCLUSION: The only outcome measure significantly different between plating groups was the post-procedural radial length. The change in length compared to intact radii was <1%, regardless of the plating group, and unlikely to be clinically relevant. Faculty of Veterinary Medicine 2023-05 2023-05-01 /pmc/articles/PMC10257463/ /pubmed/37304599 http://dx.doi.org/10.5455/OVJ.2023.v13.i5.1 Text en https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Research
Lederer, XiaoXiao Jade
Lewis, Daniel Dean
Comparison of cranial versus medial minimally invasive plate osteosynthesis applications for the stabilization of simulated radius and ulna fractures in dog cadavers
title Comparison of cranial versus medial minimally invasive plate osteosynthesis applications for the stabilization of simulated radius and ulna fractures in dog cadavers
title_full Comparison of cranial versus medial minimally invasive plate osteosynthesis applications for the stabilization of simulated radius and ulna fractures in dog cadavers
title_fullStr Comparison of cranial versus medial minimally invasive plate osteosynthesis applications for the stabilization of simulated radius and ulna fractures in dog cadavers
title_full_unstemmed Comparison of cranial versus medial minimally invasive plate osteosynthesis applications for the stabilization of simulated radius and ulna fractures in dog cadavers
title_short Comparison of cranial versus medial minimally invasive plate osteosynthesis applications for the stabilization of simulated radius and ulna fractures in dog cadavers
title_sort comparison of cranial versus medial minimally invasive plate osteosynthesis applications for the stabilization of simulated radius and ulna fractures in dog cadavers
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10257463/
https://www.ncbi.nlm.nih.gov/pubmed/37304599
http://dx.doi.org/10.5455/OVJ.2023.v13.i5.1
work_keys_str_mv AT ledererxiaoxiaojade comparisonofcranialversusmedialminimallyinvasiveplateosteosynthesisapplicationsforthestabilizationofsimulatedradiusandulnafracturesindogcadavers
AT lewisdanieldean comparisonofcranialversusmedialminimallyinvasiveplateosteosynthesisapplicationsforthestabilizationofsimulatedradiusandulnafracturesindogcadavers