Cargando…

Comparison of pathogen detection consistency between metagenomic next-generation sequencing and blood culture in patients with suspected bloodstream infection

The application of metagenomic next-generation sequencing (mNGS) has gradually been carried out by clinical practitioner. However, few studies have compared it with blood cultures in patients suffering from suspected bloodstream infections. The purpose of this study was to compare the detection of p...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhou, Yuhua, Shi, Wen, Wen, Yi, Mao, Enqiang, Ni, Tongtian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10257643/
https://www.ncbi.nlm.nih.gov/pubmed/37301921
http://dx.doi.org/10.1038/s41598-023-36681-5
_version_ 1785057343889735680
author Zhou, Yuhua
Shi, Wen
Wen, Yi
Mao, Enqiang
Ni, Tongtian
author_facet Zhou, Yuhua
Shi, Wen
Wen, Yi
Mao, Enqiang
Ni, Tongtian
author_sort Zhou, Yuhua
collection PubMed
description The application of metagenomic next-generation sequencing (mNGS) has gradually been carried out by clinical practitioner. However, few studies have compared it with blood cultures in patients suffering from suspected bloodstream infections. The purpose of this study was to compare the detection of pathogenic microorganisms by these two assays in patients with suspected bloodstream infection. We retrospectively studied patients with fever, chills, antibiotic use for more than 3 days, suspected bloodstream infection, and admission to the emergency department of Ruijin Hospital from January 2020 to June 2022. All patients had blood drawn on the same day for blood mNGS and blood cultures. Clinical and laboratory parameters were collected on the day blood was drawn. The detection of pathogenic microorganisms by the two methods was compared. Risk factors and in-hospital mortality in patients with bloodstream infections were analysed separately for these two assays. In all 99 patients, the pathogenic microorganisms detection rate in blood mNGS was significantly higher than that in blood culture. Blood mNGS was consistent with blood culture in only 12.00% of all positive bacterial and fungal test results. The level of CRP is related to bacteraemia, fungaemia and viraemia detected by blood mNGS. No clear risk factors could be found in patients with a positive blood culture. In critically ill patients, both tests failed to improve patient outcomes. In patients with suspected bloodstream infection, mNGS is not yet a complete replacement for blood cultures.
format Online
Article
Text
id pubmed-10257643
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-102576432023-06-12 Comparison of pathogen detection consistency between metagenomic next-generation sequencing and blood culture in patients with suspected bloodstream infection Zhou, Yuhua Shi, Wen Wen, Yi Mao, Enqiang Ni, Tongtian Sci Rep Article The application of metagenomic next-generation sequencing (mNGS) has gradually been carried out by clinical practitioner. However, few studies have compared it with blood cultures in patients suffering from suspected bloodstream infections. The purpose of this study was to compare the detection of pathogenic microorganisms by these two assays in patients with suspected bloodstream infection. We retrospectively studied patients with fever, chills, antibiotic use for more than 3 days, suspected bloodstream infection, and admission to the emergency department of Ruijin Hospital from January 2020 to June 2022. All patients had blood drawn on the same day for blood mNGS and blood cultures. Clinical and laboratory parameters were collected on the day blood was drawn. The detection of pathogenic microorganisms by the two methods was compared. Risk factors and in-hospital mortality in patients with bloodstream infections were analysed separately for these two assays. In all 99 patients, the pathogenic microorganisms detection rate in blood mNGS was significantly higher than that in blood culture. Blood mNGS was consistent with blood culture in only 12.00% of all positive bacterial and fungal test results. The level of CRP is related to bacteraemia, fungaemia and viraemia detected by blood mNGS. No clear risk factors could be found in patients with a positive blood culture. In critically ill patients, both tests failed to improve patient outcomes. In patients with suspected bloodstream infection, mNGS is not yet a complete replacement for blood cultures. Nature Publishing Group UK 2023-06-10 /pmc/articles/PMC10257643/ /pubmed/37301921 http://dx.doi.org/10.1038/s41598-023-36681-5 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Zhou, Yuhua
Shi, Wen
Wen, Yi
Mao, Enqiang
Ni, Tongtian
Comparison of pathogen detection consistency between metagenomic next-generation sequencing and blood culture in patients with suspected bloodstream infection
title Comparison of pathogen detection consistency between metagenomic next-generation sequencing and blood culture in patients with suspected bloodstream infection
title_full Comparison of pathogen detection consistency between metagenomic next-generation sequencing and blood culture in patients with suspected bloodstream infection
title_fullStr Comparison of pathogen detection consistency between metagenomic next-generation sequencing and blood culture in patients with suspected bloodstream infection
title_full_unstemmed Comparison of pathogen detection consistency between metagenomic next-generation sequencing and blood culture in patients with suspected bloodstream infection
title_short Comparison of pathogen detection consistency between metagenomic next-generation sequencing and blood culture in patients with suspected bloodstream infection
title_sort comparison of pathogen detection consistency between metagenomic next-generation sequencing and blood culture in patients with suspected bloodstream infection
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10257643/
https://www.ncbi.nlm.nih.gov/pubmed/37301921
http://dx.doi.org/10.1038/s41598-023-36681-5
work_keys_str_mv AT zhouyuhua comparisonofpathogendetectionconsistencybetweenmetagenomicnextgenerationsequencingandbloodcultureinpatientswithsuspectedbloodstreaminfection
AT shiwen comparisonofpathogendetectionconsistencybetweenmetagenomicnextgenerationsequencingandbloodcultureinpatientswithsuspectedbloodstreaminfection
AT wenyi comparisonofpathogendetectionconsistencybetweenmetagenomicnextgenerationsequencingandbloodcultureinpatientswithsuspectedbloodstreaminfection
AT maoenqiang comparisonofpathogendetectionconsistencybetweenmetagenomicnextgenerationsequencingandbloodcultureinpatientswithsuspectedbloodstreaminfection
AT nitongtian comparisonofpathogendetectionconsistencybetweenmetagenomicnextgenerationsequencingandbloodcultureinpatientswithsuspectedbloodstreaminfection