Cargando…

Quantitative Biomechanical Evaluation for Optimal Spinal Instrumentation to Prevent Mechanical Complications in Spinal Fusion from the Lower Thoracic Spine to the Pelvis for Adult Spinal Deformity: A Finite Element Analysis

INTRODUCTION: Mechanical complications, such as rod fracture (RF) and proximal junctional kyphosis (PJK), commonly occur after adult spinal deformity (ASD) surgery. A rigid construct is preferred to prevent RF, whereas it is a risk factor for PJK. This controversial issue urged us to conduct a biome...

Descripción completa

Detalles Bibliográficos
Autores principales: Kozaki, Takuhei, Tsutsui, Shunji, Yamamoto, Ei, Murata, Akimasa, Nakanishi, Ryuichiro, Yamada, Hiroshi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Japanese Society for Spine Surgery and Related Research 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10257959/
https://www.ncbi.nlm.nih.gov/pubmed/37309490
http://dx.doi.org/10.22603/ssrr.2022-0131
_version_ 1785057391890399232
author Kozaki, Takuhei
Tsutsui, Shunji
Yamamoto, Ei
Murata, Akimasa
Nakanishi, Ryuichiro
Yamada, Hiroshi
author_facet Kozaki, Takuhei
Tsutsui, Shunji
Yamamoto, Ei
Murata, Akimasa
Nakanishi, Ryuichiro
Yamada, Hiroshi
author_sort Kozaki, Takuhei
collection PubMed
description INTRODUCTION: Mechanical complications, such as rod fracture (RF) and proximal junctional kyphosis (PJK), commonly occur after adult spinal deformity (ASD) surgery. A rigid construct is preferred to prevent RF, whereas it is a risk factor for PJK. This controversial issue urged us to conduct a biomechanical study for seeking the optimal construct to prevent mechanical complications. METHODS: A three-dimensional nonlinear finite element model, which consisted of the lower thoracic and lumbar spine, pelvis, and femur, was created. The model was instrumented with pedicle screws (PSs), S2-alar-iliac screws, lumbar interbody fusion cages, and rods. Rod stress was measured when a forward-bending load was applied at the top of the construct to evaluate the risk of RF in constructs with or without accessory rods (ARs). In addition, fracture analysis around the uppermost instrumented vertebra (UIV) was performed to assess the risk of PJK. RESULTS: Changing the rod material from titanium alloy (Ti) to cobalt chrome (CoCr) decreased shearing stress at L5-S1 by 11.5%, and adding ARs decreased it by up to 34.3% (for the shortest ARs). Although the trajectory (straightforward vs. anatomical) of PSs did not affect the fracture load for UIV+1, changing the anchor from PSs to hooks at the UIV reduced it by 14.8%. Changing the rod material from Ti to CoCr did not alter the load, whereas the load decreased by up to 25.1% as the AR became longer. CONCLUSIONS: The PSs at the UIV in the lower thoracic spine, CoCr rods as primary rods, and shorter ARs should be used in long fusion for ASD to prevent mechanical complications.
format Online
Article
Text
id pubmed-10257959
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher The Japanese Society for Spine Surgery and Related Research
record_format MEDLINE/PubMed
spelling pubmed-102579592023-06-12 Quantitative Biomechanical Evaluation for Optimal Spinal Instrumentation to Prevent Mechanical Complications in Spinal Fusion from the Lower Thoracic Spine to the Pelvis for Adult Spinal Deformity: A Finite Element Analysis Kozaki, Takuhei Tsutsui, Shunji Yamamoto, Ei Murata, Akimasa Nakanishi, Ryuichiro Yamada, Hiroshi Spine Surg Relat Res Original Article INTRODUCTION: Mechanical complications, such as rod fracture (RF) and proximal junctional kyphosis (PJK), commonly occur after adult spinal deformity (ASD) surgery. A rigid construct is preferred to prevent RF, whereas it is a risk factor for PJK. This controversial issue urged us to conduct a biomechanical study for seeking the optimal construct to prevent mechanical complications. METHODS: A three-dimensional nonlinear finite element model, which consisted of the lower thoracic and lumbar spine, pelvis, and femur, was created. The model was instrumented with pedicle screws (PSs), S2-alar-iliac screws, lumbar interbody fusion cages, and rods. Rod stress was measured when a forward-bending load was applied at the top of the construct to evaluate the risk of RF in constructs with or without accessory rods (ARs). In addition, fracture analysis around the uppermost instrumented vertebra (UIV) was performed to assess the risk of PJK. RESULTS: Changing the rod material from titanium alloy (Ti) to cobalt chrome (CoCr) decreased shearing stress at L5-S1 by 11.5%, and adding ARs decreased it by up to 34.3% (for the shortest ARs). Although the trajectory (straightforward vs. anatomical) of PSs did not affect the fracture load for UIV+1, changing the anchor from PSs to hooks at the UIV reduced it by 14.8%. Changing the rod material from Ti to CoCr did not alter the load, whereas the load decreased by up to 25.1% as the AR became longer. CONCLUSIONS: The PSs at the UIV in the lower thoracic spine, CoCr rods as primary rods, and shorter ARs should be used in long fusion for ASD to prevent mechanical complications. The Japanese Society for Spine Surgery and Related Research 2023-01-12 /pmc/articles/PMC10257959/ /pubmed/37309490 http://dx.doi.org/10.22603/ssrr.2022-0131 Text en Copyright © 2023 The Japanese Society for Spine Surgery and Related Research https://creativecommons.org/licenses/by-nc-nd/4.0/Spine Surgery and Related Research is an Open Access journal distributed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. To view the details of this license, please visit (https://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Kozaki, Takuhei
Tsutsui, Shunji
Yamamoto, Ei
Murata, Akimasa
Nakanishi, Ryuichiro
Yamada, Hiroshi
Quantitative Biomechanical Evaluation for Optimal Spinal Instrumentation to Prevent Mechanical Complications in Spinal Fusion from the Lower Thoracic Spine to the Pelvis for Adult Spinal Deformity: A Finite Element Analysis
title Quantitative Biomechanical Evaluation for Optimal Spinal Instrumentation to Prevent Mechanical Complications in Spinal Fusion from the Lower Thoracic Spine to the Pelvis for Adult Spinal Deformity: A Finite Element Analysis
title_full Quantitative Biomechanical Evaluation for Optimal Spinal Instrumentation to Prevent Mechanical Complications in Spinal Fusion from the Lower Thoracic Spine to the Pelvis for Adult Spinal Deformity: A Finite Element Analysis
title_fullStr Quantitative Biomechanical Evaluation for Optimal Spinal Instrumentation to Prevent Mechanical Complications in Spinal Fusion from the Lower Thoracic Spine to the Pelvis for Adult Spinal Deformity: A Finite Element Analysis
title_full_unstemmed Quantitative Biomechanical Evaluation for Optimal Spinal Instrumentation to Prevent Mechanical Complications in Spinal Fusion from the Lower Thoracic Spine to the Pelvis for Adult Spinal Deformity: A Finite Element Analysis
title_short Quantitative Biomechanical Evaluation for Optimal Spinal Instrumentation to Prevent Mechanical Complications in Spinal Fusion from the Lower Thoracic Spine to the Pelvis for Adult Spinal Deformity: A Finite Element Analysis
title_sort quantitative biomechanical evaluation for optimal spinal instrumentation to prevent mechanical complications in spinal fusion from the lower thoracic spine to the pelvis for adult spinal deformity: a finite element analysis
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10257959/
https://www.ncbi.nlm.nih.gov/pubmed/37309490
http://dx.doi.org/10.22603/ssrr.2022-0131
work_keys_str_mv AT kozakitakuhei quantitativebiomechanicalevaluationforoptimalspinalinstrumentationtopreventmechanicalcomplicationsinspinalfusionfromthelowerthoracicspinetothepelvisforadultspinaldeformityafiniteelementanalysis
AT tsutsuishunji quantitativebiomechanicalevaluationforoptimalspinalinstrumentationtopreventmechanicalcomplicationsinspinalfusionfromthelowerthoracicspinetothepelvisforadultspinaldeformityafiniteelementanalysis
AT yamamotoei quantitativebiomechanicalevaluationforoptimalspinalinstrumentationtopreventmechanicalcomplicationsinspinalfusionfromthelowerthoracicspinetothepelvisforadultspinaldeformityafiniteelementanalysis
AT murataakimasa quantitativebiomechanicalevaluationforoptimalspinalinstrumentationtopreventmechanicalcomplicationsinspinalfusionfromthelowerthoracicspinetothepelvisforadultspinaldeformityafiniteelementanalysis
AT nakanishiryuichiro quantitativebiomechanicalevaluationforoptimalspinalinstrumentationtopreventmechanicalcomplicationsinspinalfusionfromthelowerthoracicspinetothepelvisforadultspinaldeformityafiniteelementanalysis
AT yamadahiroshi quantitativebiomechanicalevaluationforoptimalspinalinstrumentationtopreventmechanicalcomplicationsinspinalfusionfromthelowerthoracicspinetothepelvisforadultspinaldeformityafiniteelementanalysis