Cargando…

Magnetic resonance three-dimensional steady-state free precession imaging of the thoracic duct in patients with Fontan circulation and its relationship to outcomes

BACKGROUND: Lymphatic complications are common in patients with Fontan circulation. Three-dimensional balanced steady-state free precession (3D bSSFP) angiography by cardiovascular magnetic resonance (CMR) is widely used for cardiovascular anatomical assessment. We sought to determine the frequency...

Descripción completa

Detalles Bibliográficos
Autores principales: Castellanos, Daniel A., Ahmad, Sidra, St. Clair, Nicole, Sleeper, Lynn A., Lu, Minmin, Schidlow, David N., Rathod, Rahul H., Yin, Suellen M., Esch, Jesse J., Annese, David, Powell, Andrew J., Quiñonez, Luis, Shaikh, Raja, Ghelani, Sunil J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10258944/
https://www.ncbi.nlm.nih.gov/pubmed/37303061
http://dx.doi.org/10.1186/s12968-023-00937-w
_version_ 1785057564834136064
author Castellanos, Daniel A.
Ahmad, Sidra
St. Clair, Nicole
Sleeper, Lynn A.
Lu, Minmin
Schidlow, David N.
Rathod, Rahul H.
Yin, Suellen M.
Esch, Jesse J.
Annese, David
Powell, Andrew J.
Quiñonez, Luis
Shaikh, Raja
Ghelani, Sunil J.
author_facet Castellanos, Daniel A.
Ahmad, Sidra
St. Clair, Nicole
Sleeper, Lynn A.
Lu, Minmin
Schidlow, David N.
Rathod, Rahul H.
Yin, Suellen M.
Esch, Jesse J.
Annese, David
Powell, Andrew J.
Quiñonez, Luis
Shaikh, Raja
Ghelani, Sunil J.
author_sort Castellanos, Daniel A.
collection PubMed
description BACKGROUND: Lymphatic complications are common in patients with Fontan circulation. Three-dimensional balanced steady-state free precession (3D bSSFP) angiography by cardiovascular magnetic resonance (CMR) is widely used for cardiovascular anatomical assessment. We sought to determine the frequency of thoracic duct (TD) visualization using 3D bSSFP images and assess whether TD characteristics are associated with clinical outcomes. METHODS: This was a retrospective, single-center study of patients with Fontan circulation who underwent CMR. Frequency matching of age at CMR was used to construct a comparison group of patients with repaired tetralogy of Fallot (rTOF). TD characteristics included maximum diameter and a qualitative assessment of tortuosity. Clinical outcomes included protein-losing enteropathy (PLE), plastic bronchitis, listing for heart transplantation, and death. A composite outcome was defined as presence of any of these events. RESULTS: The study included 189 Fontan patients (median age 16.1 years, IQR 11.0–23.2 years) and 36 rTOF patients (median age 15.7 years, IQR 11.1–23.7 years). The TD diameter was larger (median 2.50 vs. 1.95 mm, p = 0.002) and more often well visualized (65% vs. 22%, p < 0.001) in Fontan patients vs. rTOF patients. TD dimension increased mildly with age in Fontan patients, R = 0.19, p = 0.01. In Fontan patients, the TD diameter was larger in those with PLE vs. without PLE (age-adjusted mean 4.11 vs. 2.72, p = 0.005), and was more tortuous in those with NYHA class ≥ II vs. class I (moderate or greater tortuosity 75% vs. 28.5%, p = 0.02). Larger TD diameter was associated with a lower ventricular ejection fraction that was independent of age (partial correlation = − 0.22, p = 0.02). More tortuous TDs had a higher end-systolic volume (mean 70.0 mL/m(2) vs. 57.3 mL/m(2), p = 0.03), lower creatinine (mean 0.61 mg/dL vs. 0.70 mg/dL, p = 0.04), and a higher absolute lymphocyte count (mean 1.80 K cells/µL vs. 0.76 K cells/µL, p = 0.003). The composite outcome was present in 6% of Fontan patients and was not associated with TD diameter (p = 0.50) or tortuosity (p = 0.09). CONCLUSIONS: The TD is well visualized in two-thirds of patients with Fontan circulation on 3D-bSSFP images. Larger TD diameter is associated with PLE and increased TD tortuosity is associated with an NYHA class ≥ II. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12968-023-00937-w.
format Online
Article
Text
id pubmed-10258944
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-102589442023-06-13 Magnetic resonance three-dimensional steady-state free precession imaging of the thoracic duct in patients with Fontan circulation and its relationship to outcomes Castellanos, Daniel A. Ahmad, Sidra St. Clair, Nicole Sleeper, Lynn A. Lu, Minmin Schidlow, David N. Rathod, Rahul H. Yin, Suellen M. Esch, Jesse J. Annese, David Powell, Andrew J. Quiñonez, Luis Shaikh, Raja Ghelani, Sunil J. J Cardiovasc Magn Reson Research BACKGROUND: Lymphatic complications are common in patients with Fontan circulation. Three-dimensional balanced steady-state free precession (3D bSSFP) angiography by cardiovascular magnetic resonance (CMR) is widely used for cardiovascular anatomical assessment. We sought to determine the frequency of thoracic duct (TD) visualization using 3D bSSFP images and assess whether TD characteristics are associated with clinical outcomes. METHODS: This was a retrospective, single-center study of patients with Fontan circulation who underwent CMR. Frequency matching of age at CMR was used to construct a comparison group of patients with repaired tetralogy of Fallot (rTOF). TD characteristics included maximum diameter and a qualitative assessment of tortuosity. Clinical outcomes included protein-losing enteropathy (PLE), plastic bronchitis, listing for heart transplantation, and death. A composite outcome was defined as presence of any of these events. RESULTS: The study included 189 Fontan patients (median age 16.1 years, IQR 11.0–23.2 years) and 36 rTOF patients (median age 15.7 years, IQR 11.1–23.7 years). The TD diameter was larger (median 2.50 vs. 1.95 mm, p = 0.002) and more often well visualized (65% vs. 22%, p < 0.001) in Fontan patients vs. rTOF patients. TD dimension increased mildly with age in Fontan patients, R = 0.19, p = 0.01. In Fontan patients, the TD diameter was larger in those with PLE vs. without PLE (age-adjusted mean 4.11 vs. 2.72, p = 0.005), and was more tortuous in those with NYHA class ≥ II vs. class I (moderate or greater tortuosity 75% vs. 28.5%, p = 0.02). Larger TD diameter was associated with a lower ventricular ejection fraction that was independent of age (partial correlation = − 0.22, p = 0.02). More tortuous TDs had a higher end-systolic volume (mean 70.0 mL/m(2) vs. 57.3 mL/m(2), p = 0.03), lower creatinine (mean 0.61 mg/dL vs. 0.70 mg/dL, p = 0.04), and a higher absolute lymphocyte count (mean 1.80 K cells/µL vs. 0.76 K cells/µL, p = 0.003). The composite outcome was present in 6% of Fontan patients and was not associated with TD diameter (p = 0.50) or tortuosity (p = 0.09). CONCLUSIONS: The TD is well visualized in two-thirds of patients with Fontan circulation on 3D-bSSFP images. Larger TD diameter is associated with PLE and increased TD tortuosity is associated with an NYHA class ≥ II. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12968-023-00937-w. BioMed Central 2023-06-12 /pmc/articles/PMC10258944/ /pubmed/37303061 http://dx.doi.org/10.1186/s12968-023-00937-w Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Castellanos, Daniel A.
Ahmad, Sidra
St. Clair, Nicole
Sleeper, Lynn A.
Lu, Minmin
Schidlow, David N.
Rathod, Rahul H.
Yin, Suellen M.
Esch, Jesse J.
Annese, David
Powell, Andrew J.
Quiñonez, Luis
Shaikh, Raja
Ghelani, Sunil J.
Magnetic resonance three-dimensional steady-state free precession imaging of the thoracic duct in patients with Fontan circulation and its relationship to outcomes
title Magnetic resonance three-dimensional steady-state free precession imaging of the thoracic duct in patients with Fontan circulation and its relationship to outcomes
title_full Magnetic resonance three-dimensional steady-state free precession imaging of the thoracic duct in patients with Fontan circulation and its relationship to outcomes
title_fullStr Magnetic resonance three-dimensional steady-state free precession imaging of the thoracic duct in patients with Fontan circulation and its relationship to outcomes
title_full_unstemmed Magnetic resonance three-dimensional steady-state free precession imaging of the thoracic duct in patients with Fontan circulation and its relationship to outcomes
title_short Magnetic resonance three-dimensional steady-state free precession imaging of the thoracic duct in patients with Fontan circulation and its relationship to outcomes
title_sort magnetic resonance three-dimensional steady-state free precession imaging of the thoracic duct in patients with fontan circulation and its relationship to outcomes
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10258944/
https://www.ncbi.nlm.nih.gov/pubmed/37303061
http://dx.doi.org/10.1186/s12968-023-00937-w
work_keys_str_mv AT castellanosdaniela magneticresonancethreedimensionalsteadystatefreeprecessionimagingofthethoracicductinpatientswithfontancirculationanditsrelationshiptooutcomes
AT ahmadsidra magneticresonancethreedimensionalsteadystatefreeprecessionimagingofthethoracicductinpatientswithfontancirculationanditsrelationshiptooutcomes
AT stclairnicole magneticresonancethreedimensionalsteadystatefreeprecessionimagingofthethoracicductinpatientswithfontancirculationanditsrelationshiptooutcomes
AT sleeperlynna magneticresonancethreedimensionalsteadystatefreeprecessionimagingofthethoracicductinpatientswithfontancirculationanditsrelationshiptooutcomes
AT luminmin magneticresonancethreedimensionalsteadystatefreeprecessionimagingofthethoracicductinpatientswithfontancirculationanditsrelationshiptooutcomes
AT schidlowdavidn magneticresonancethreedimensionalsteadystatefreeprecessionimagingofthethoracicductinpatientswithfontancirculationanditsrelationshiptooutcomes
AT rathodrahulh magneticresonancethreedimensionalsteadystatefreeprecessionimagingofthethoracicductinpatientswithfontancirculationanditsrelationshiptooutcomes
AT yinsuellenm magneticresonancethreedimensionalsteadystatefreeprecessionimagingofthethoracicductinpatientswithfontancirculationanditsrelationshiptooutcomes
AT eschjessej magneticresonancethreedimensionalsteadystatefreeprecessionimagingofthethoracicductinpatientswithfontancirculationanditsrelationshiptooutcomes
AT annesedavid magneticresonancethreedimensionalsteadystatefreeprecessionimagingofthethoracicductinpatientswithfontancirculationanditsrelationshiptooutcomes
AT powellandrewj magneticresonancethreedimensionalsteadystatefreeprecessionimagingofthethoracicductinpatientswithfontancirculationanditsrelationshiptooutcomes
AT quinonezluis magneticresonancethreedimensionalsteadystatefreeprecessionimagingofthethoracicductinpatientswithfontancirculationanditsrelationshiptooutcomes
AT shaikhraja magneticresonancethreedimensionalsteadystatefreeprecessionimagingofthethoracicductinpatientswithfontancirculationanditsrelationshiptooutcomes
AT ghelanisunilj magneticresonancethreedimensionalsteadystatefreeprecessionimagingofthethoracicductinpatientswithfontancirculationanditsrelationshiptooutcomes