Cargando…
Non-invasive measurement of liver iron concentration by magnetic resonance imaging and its clinical usefulness
Determination of liver iron concentration by magnetic resonance imaging (MRI) is becoming the new technique of choice for the diagnosis of iron overload in hereditary haemochromatosis and other liver iron surcharge diseases. Determination of hepatic iron concentration obtained by liver biopsy has be...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Termedia Publishing House
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10259395/ https://www.ncbi.nlm.nih.gov/pubmed/37313200 http://dx.doi.org/10.5114/aoms/119118 |
_version_ | 1785057652309491712 |
---|---|
author | Alustiza, Jose M. Castiella, Agustin Zapata, Eva Urreta, Iratxe Salvador, Emma Emparanza, Jose I. |
author_facet | Alustiza, Jose M. Castiella, Agustin Zapata, Eva Urreta, Iratxe Salvador, Emma Emparanza, Jose I. |
author_sort | Alustiza, Jose M. |
collection | PubMed |
description | Determination of liver iron concentration by magnetic resonance imaging (MRI) is becoming the new technique of choice for the diagnosis of iron overload in hereditary haemochromatosis and other liver iron surcharge diseases. Determination of hepatic iron concentration obtained by liver biopsy has been the gold standard for years. The development of MRI techniques, via signal intensity ratio methods or relaxometry, has provided a non-invasive and more accurate approach to the diagnosis of liver iron overload. This article reviews the available MRI methods for the determination of liver iron concentration and also evaluates the technique for the diagnosis and quantification of iron overload in different clinical practice scenarios. |
format | Online Article Text |
id | pubmed-10259395 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Termedia Publishing House |
record_format | MEDLINE/PubMed |
spelling | pubmed-102593952023-06-13 Non-invasive measurement of liver iron concentration by magnetic resonance imaging and its clinical usefulness Alustiza, Jose M. Castiella, Agustin Zapata, Eva Urreta, Iratxe Salvador, Emma Emparanza, Jose I. Arch Med Sci State of the Art Paper Determination of liver iron concentration by magnetic resonance imaging (MRI) is becoming the new technique of choice for the diagnosis of iron overload in hereditary haemochromatosis and other liver iron surcharge diseases. Determination of hepatic iron concentration obtained by liver biopsy has been the gold standard for years. The development of MRI techniques, via signal intensity ratio methods or relaxometry, has provided a non-invasive and more accurate approach to the diagnosis of liver iron overload. This article reviews the available MRI methods for the determination of liver iron concentration and also evaluates the technique for the diagnosis and quantification of iron overload in different clinical practice scenarios. Termedia Publishing House 2021-02-03 /pmc/articles/PMC10259395/ /pubmed/37313200 http://dx.doi.org/10.5114/aoms/119118 Text en Copyright: © 2021 Termedia & Banach https://creativecommons.org/licenses/by-nc-sa/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) License, allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material, provided the original work is properly cited and states its license. |
spellingShingle | State of the Art Paper Alustiza, Jose M. Castiella, Agustin Zapata, Eva Urreta, Iratxe Salvador, Emma Emparanza, Jose I. Non-invasive measurement of liver iron concentration by magnetic resonance imaging and its clinical usefulness |
title | Non-invasive measurement of liver iron concentration by magnetic resonance imaging and its clinical usefulness |
title_full | Non-invasive measurement of liver iron concentration by magnetic resonance imaging and its clinical usefulness |
title_fullStr | Non-invasive measurement of liver iron concentration by magnetic resonance imaging and its clinical usefulness |
title_full_unstemmed | Non-invasive measurement of liver iron concentration by magnetic resonance imaging and its clinical usefulness |
title_short | Non-invasive measurement of liver iron concentration by magnetic resonance imaging and its clinical usefulness |
title_sort | non-invasive measurement of liver iron concentration by magnetic resonance imaging and its clinical usefulness |
topic | State of the Art Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10259395/ https://www.ncbi.nlm.nih.gov/pubmed/37313200 http://dx.doi.org/10.5114/aoms/119118 |
work_keys_str_mv | AT alustizajosem noninvasivemeasurementofliverironconcentrationbymagneticresonanceimaginganditsclinicalusefulness AT castiellaagustin noninvasivemeasurementofliverironconcentrationbymagneticresonanceimaginganditsclinicalusefulness AT zapataeva noninvasivemeasurementofliverironconcentrationbymagneticresonanceimaginganditsclinicalusefulness AT urretairatxe noninvasivemeasurementofliverironconcentrationbymagneticresonanceimaginganditsclinicalusefulness AT salvadoremma noninvasivemeasurementofliverironconcentrationbymagneticresonanceimaginganditsclinicalusefulness AT emparanzajosei noninvasivemeasurementofliverironconcentrationbymagneticresonanceimaginganditsclinicalusefulness |