Cargando…

Non-invasive measurement of liver iron concentration by magnetic resonance imaging and its clinical usefulness

Determination of liver iron concentration by magnetic resonance imaging (MRI) is becoming the new technique of choice for the diagnosis of iron overload in hereditary haemochromatosis and other liver iron surcharge diseases. Determination of hepatic iron concentration obtained by liver biopsy has be...

Descripción completa

Detalles Bibliográficos
Autores principales: Alustiza, Jose M., Castiella, Agustin, Zapata, Eva, Urreta, Iratxe, Salvador, Emma, Emparanza, Jose I.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Termedia Publishing House 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10259395/
https://www.ncbi.nlm.nih.gov/pubmed/37313200
http://dx.doi.org/10.5114/aoms/119118
_version_ 1785057652309491712
author Alustiza, Jose M.
Castiella, Agustin
Zapata, Eva
Urreta, Iratxe
Salvador, Emma
Emparanza, Jose I.
author_facet Alustiza, Jose M.
Castiella, Agustin
Zapata, Eva
Urreta, Iratxe
Salvador, Emma
Emparanza, Jose I.
author_sort Alustiza, Jose M.
collection PubMed
description Determination of liver iron concentration by magnetic resonance imaging (MRI) is becoming the new technique of choice for the diagnosis of iron overload in hereditary haemochromatosis and other liver iron surcharge diseases. Determination of hepatic iron concentration obtained by liver biopsy has been the gold standard for years. The development of MRI techniques, via signal intensity ratio methods or relaxometry, has provided a non-invasive and more accurate approach to the diagnosis of liver iron overload. This article reviews the available MRI methods for the determination of liver iron concentration and also evaluates the technique for the diagnosis and quantification of iron overload in different clinical practice scenarios.
format Online
Article
Text
id pubmed-10259395
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Termedia Publishing House
record_format MEDLINE/PubMed
spelling pubmed-102593952023-06-13 Non-invasive measurement of liver iron concentration by magnetic resonance imaging and its clinical usefulness Alustiza, Jose M. Castiella, Agustin Zapata, Eva Urreta, Iratxe Salvador, Emma Emparanza, Jose I. Arch Med Sci State of the Art Paper Determination of liver iron concentration by magnetic resonance imaging (MRI) is becoming the new technique of choice for the diagnosis of iron overload in hereditary haemochromatosis and other liver iron surcharge diseases. Determination of hepatic iron concentration obtained by liver biopsy has been the gold standard for years. The development of MRI techniques, via signal intensity ratio methods or relaxometry, has provided a non-invasive and more accurate approach to the diagnosis of liver iron overload. This article reviews the available MRI methods for the determination of liver iron concentration and also evaluates the technique for the diagnosis and quantification of iron overload in different clinical practice scenarios. Termedia Publishing House 2021-02-03 /pmc/articles/PMC10259395/ /pubmed/37313200 http://dx.doi.org/10.5114/aoms/119118 Text en Copyright: © 2021 Termedia & Banach https://creativecommons.org/licenses/by-nc-sa/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) License, allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material, provided the original work is properly cited and states its license.
spellingShingle State of the Art Paper
Alustiza, Jose M.
Castiella, Agustin
Zapata, Eva
Urreta, Iratxe
Salvador, Emma
Emparanza, Jose I.
Non-invasive measurement of liver iron concentration by magnetic resonance imaging and its clinical usefulness
title Non-invasive measurement of liver iron concentration by magnetic resonance imaging and its clinical usefulness
title_full Non-invasive measurement of liver iron concentration by magnetic resonance imaging and its clinical usefulness
title_fullStr Non-invasive measurement of liver iron concentration by magnetic resonance imaging and its clinical usefulness
title_full_unstemmed Non-invasive measurement of liver iron concentration by magnetic resonance imaging and its clinical usefulness
title_short Non-invasive measurement of liver iron concentration by magnetic resonance imaging and its clinical usefulness
title_sort non-invasive measurement of liver iron concentration by magnetic resonance imaging and its clinical usefulness
topic State of the Art Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10259395/
https://www.ncbi.nlm.nih.gov/pubmed/37313200
http://dx.doi.org/10.5114/aoms/119118
work_keys_str_mv AT alustizajosem noninvasivemeasurementofliverironconcentrationbymagneticresonanceimaginganditsclinicalusefulness
AT castiellaagustin noninvasivemeasurementofliverironconcentrationbymagneticresonanceimaginganditsclinicalusefulness
AT zapataeva noninvasivemeasurementofliverironconcentrationbymagneticresonanceimaginganditsclinicalusefulness
AT urretairatxe noninvasivemeasurementofliverironconcentrationbymagneticresonanceimaginganditsclinicalusefulness
AT salvadoremma noninvasivemeasurementofliverironconcentrationbymagneticresonanceimaginganditsclinicalusefulness
AT emparanzajosei noninvasivemeasurementofliverironconcentrationbymagneticresonanceimaginganditsclinicalusefulness