Cargando…

Feasibility of Dedicated Breast Positron Emission Tomography Image Denoising Using a Residual Neural Network

OBJECTIVE(S): This study aimed to create a deep learning (DL)-based denoising model using a residual neural network (Res-Net) trained to reduce noise in ring-type dedicated breast positron emission tomography (dbPET) images acquired in about half the emission time, and to evaluate the feasibility an...

Descripción completa

Detalles Bibliográficos
Autores principales: Itagaki, Koji, Miyake, Kanae K., Tanoue, Minori, Oishi, Tae, Kataoka, Masako, Kawashima, Masahiro, Toi, Masakazu, Nakamoto, Yuji
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Mashhad University of Medical Sciences 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10261694/
https://www.ncbi.nlm.nih.gov/pubmed/37324225
http://dx.doi.org/10.22038/AOJNMB.2023.71598.1501
_version_ 1785057921060569088
author Itagaki, Koji
Miyake, Kanae K.
Tanoue, Minori
Oishi, Tae
Kataoka, Masako
Kawashima, Masahiro
Toi, Masakazu
Nakamoto, Yuji
author_facet Itagaki, Koji
Miyake, Kanae K.
Tanoue, Minori
Oishi, Tae
Kataoka, Masako
Kawashima, Masahiro
Toi, Masakazu
Nakamoto, Yuji
author_sort Itagaki, Koji
collection PubMed
description OBJECTIVE(S): This study aimed to create a deep learning (DL)-based denoising model using a residual neural network (Res-Net) trained to reduce noise in ring-type dedicated breast positron emission tomography (dbPET) images acquired in about half the emission time, and to evaluate the feasibility and the effectiveness of the model in terms of its noise reduction performance and preservation of quantitative values compared to conventional post-image filtering techniques. METHODS: Low-count (LC) and full-count (FC) PET images with acquisition durations of 3 and 7 minutes, respectively, were reconstructed. A Res-Net was trained to create a noise reduction model using fifteen patients’ data. The inputs to the network were LC images and its outputs were denoised PET (LC + DL) images, which should resemble FC images. To evaluate the LC + DL images, Gaussian and non-local mean (NLM) filters were applied to the LC images (LC + Gaussian and LC + NLM, respectively). To create reference images, a Gaussian filter was applied to the FC images (FC + Gaussian). The usefulness of our denoising model was objectively and visually evaluated using test data set of thirteen patients. The coefficient of variation (CV) of background fibroglandular tissue or fat tissue were measured to evaluate the performance of the noise reduction. The SUV(max) and SUV(peak) of lesions were also measured. The agreement of the SUV measurements was evaluated by Bland–Altman plots. RESULTS: The CV of background fibroglandular tissue in the LC + DL images was significantly lower (9.10 [Formula: see text] 2.76) than the CVs in the LC (13.60 [Formula: see text] 3.66) and LC + Gaussian images (11.51 [Formula: see text] 3.56). No significant difference was observed in both SUV(max) and SUV(peak) of lesions between LC + DL and reference images. For the visual assessment, the smoothness rating for the LC + DL images was significantly better than that for the other images except for the reference images. CONCLUSION: Our model reduced the noise in dbPET images acquired in about half the emission time while preserving quantitative values of lesions. This study demonstrates that machine learning is feasible and potentially performs better than conventional post-image filtering in dbPET denoising.
format Online
Article
Text
id pubmed-10261694
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Mashhad University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-102616942023-06-15 Feasibility of Dedicated Breast Positron Emission Tomography Image Denoising Using a Residual Neural Network Itagaki, Koji Miyake, Kanae K. Tanoue, Minori Oishi, Tae Kataoka, Masako Kawashima, Masahiro Toi, Masakazu Nakamoto, Yuji Asia Ocean J Nucl Med Biol Original Article OBJECTIVE(S): This study aimed to create a deep learning (DL)-based denoising model using a residual neural network (Res-Net) trained to reduce noise in ring-type dedicated breast positron emission tomography (dbPET) images acquired in about half the emission time, and to evaluate the feasibility and the effectiveness of the model in terms of its noise reduction performance and preservation of quantitative values compared to conventional post-image filtering techniques. METHODS: Low-count (LC) and full-count (FC) PET images with acquisition durations of 3 and 7 minutes, respectively, were reconstructed. A Res-Net was trained to create a noise reduction model using fifteen patients’ data. The inputs to the network were LC images and its outputs were denoised PET (LC + DL) images, which should resemble FC images. To evaluate the LC + DL images, Gaussian and non-local mean (NLM) filters were applied to the LC images (LC + Gaussian and LC + NLM, respectively). To create reference images, a Gaussian filter was applied to the FC images (FC + Gaussian). The usefulness of our denoising model was objectively and visually evaluated using test data set of thirteen patients. The coefficient of variation (CV) of background fibroglandular tissue or fat tissue were measured to evaluate the performance of the noise reduction. The SUV(max) and SUV(peak) of lesions were also measured. The agreement of the SUV measurements was evaluated by Bland–Altman plots. RESULTS: The CV of background fibroglandular tissue in the LC + DL images was significantly lower (9.10 [Formula: see text] 2.76) than the CVs in the LC (13.60 [Formula: see text] 3.66) and LC + Gaussian images (11.51 [Formula: see text] 3.56). No significant difference was observed in both SUV(max) and SUV(peak) of lesions between LC + DL and reference images. For the visual assessment, the smoothness rating for the LC + DL images was significantly better than that for the other images except for the reference images. CONCLUSION: Our model reduced the noise in dbPET images acquired in about half the emission time while preserving quantitative values of lesions. This study demonstrates that machine learning is feasible and potentially performs better than conventional post-image filtering in dbPET denoising. Mashhad University of Medical Sciences 2023 /pmc/articles/PMC10261694/ /pubmed/37324225 http://dx.doi.org/10.22038/AOJNMB.2023.71598.1501 Text en https://creativecommons.org/licenses/by/3.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License, (http://creativecommons.org/licenses/by/3.0/ (https://creativecommons.org/licenses/by/3.0/) ) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Itagaki, Koji
Miyake, Kanae K.
Tanoue, Minori
Oishi, Tae
Kataoka, Masako
Kawashima, Masahiro
Toi, Masakazu
Nakamoto, Yuji
Feasibility of Dedicated Breast Positron Emission Tomography Image Denoising Using a Residual Neural Network
title Feasibility of Dedicated Breast Positron Emission Tomography Image Denoising Using a Residual Neural Network
title_full Feasibility of Dedicated Breast Positron Emission Tomography Image Denoising Using a Residual Neural Network
title_fullStr Feasibility of Dedicated Breast Positron Emission Tomography Image Denoising Using a Residual Neural Network
title_full_unstemmed Feasibility of Dedicated Breast Positron Emission Tomography Image Denoising Using a Residual Neural Network
title_short Feasibility of Dedicated Breast Positron Emission Tomography Image Denoising Using a Residual Neural Network
title_sort feasibility of dedicated breast positron emission tomography image denoising using a residual neural network
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10261694/
https://www.ncbi.nlm.nih.gov/pubmed/37324225
http://dx.doi.org/10.22038/AOJNMB.2023.71598.1501
work_keys_str_mv AT itagakikoji feasibilityofdedicatedbreastpositronemissiontomographyimagedenoisingusingaresidualneuralnetwork
AT miyakekanaek feasibilityofdedicatedbreastpositronemissiontomographyimagedenoisingusingaresidualneuralnetwork
AT tanoueminori feasibilityofdedicatedbreastpositronemissiontomographyimagedenoisingusingaresidualneuralnetwork
AT oishitae feasibilityofdedicatedbreastpositronemissiontomographyimagedenoisingusingaresidualneuralnetwork
AT kataokamasako feasibilityofdedicatedbreastpositronemissiontomographyimagedenoisingusingaresidualneuralnetwork
AT kawashimamasahiro feasibilityofdedicatedbreastpositronemissiontomographyimagedenoisingusingaresidualneuralnetwork
AT toimasakazu feasibilityofdedicatedbreastpositronemissiontomographyimagedenoisingusingaresidualneuralnetwork
AT nakamotoyuji feasibilityofdedicatedbreastpositronemissiontomographyimagedenoisingusingaresidualneuralnetwork