Voltammetric determination of vitamin B6 in the presence of vitamin C based on zinc ferrite nano-particles modified screen-printed graphite electrode
The zinc ferrite nano-particles (ZnFe(2)O(4)) modified screen-printed graphite electrode (ZnFe(2)O(4)/SPGE) was used for the voltammetric determination of vitamin B(6) in real samples, using differential pulse voltammetry (DPV). It has been found that the oxidation of vitamin B(6) at the surface of...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
International Association of Physical Chemists
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10262225/ https://www.ncbi.nlm.nih.gov/pubmed/37325119 http://dx.doi.org/10.5599/admet.1702 |
_version_ | 1785058025993666560 |
---|---|
author | Jahani, Peyman Mohammadzadeh Jafari, Maedeh Ahmadi, Sayed Ali |
author_facet | Jahani, Peyman Mohammadzadeh Jafari, Maedeh Ahmadi, Sayed Ali |
author_sort | Jahani, Peyman Mohammadzadeh |
collection | PubMed |
description | The zinc ferrite nano-particles (ZnFe(2)O(4)) modified screen-printed graphite electrode (ZnFe(2)O(4)/SPGE) was used for the voltammetric determination of vitamin B(6) in real samples, using differential pulse voltammetry (DPV). It has been found that the oxidation of vitamin B(6) at the surface of such an electrode occurs at a potential about 150 mV less positive compared to an unmodified screen-printed graphite electrode. After optimization, a vitamin B6 sensor with a linear range from 0.8 to 585.0 μM and a detection limit of 0.17 μM. The ZnFe(2)O(4)/SPGE sensor exhibits good resolution between the voltammetric peaks of vitamin B(6) and vitamin C, making it suitable for detecting vitamin B(6) in the presence of vitamin C in real samples. |
format | Online Article Text |
id | pubmed-10262225 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | International Association of Physical Chemists |
record_format | MEDLINE/PubMed |
spelling | pubmed-102622252023-06-15 Voltammetric determination of vitamin B6 in the presence of vitamin C based on zinc ferrite nano-particles modified screen-printed graphite electrode Jahani, Peyman Mohammadzadeh Jafari, Maedeh Ahmadi, Sayed Ali ADMET DMPK Original Scientific Paper The zinc ferrite nano-particles (ZnFe(2)O(4)) modified screen-printed graphite electrode (ZnFe(2)O(4)/SPGE) was used for the voltammetric determination of vitamin B(6) in real samples, using differential pulse voltammetry (DPV). It has been found that the oxidation of vitamin B(6) at the surface of such an electrode occurs at a potential about 150 mV less positive compared to an unmodified screen-printed graphite electrode. After optimization, a vitamin B6 sensor with a linear range from 0.8 to 585.0 μM and a detection limit of 0.17 μM. The ZnFe(2)O(4)/SPGE sensor exhibits good resolution between the voltammetric peaks of vitamin B(6) and vitamin C, making it suitable for detecting vitamin B(6) in the presence of vitamin C in real samples. International Association of Physical Chemists 2023-03-15 /pmc/articles/PMC10262225/ /pubmed/37325119 http://dx.doi.org/10.5599/admet.1702 Text en Copyright © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/This article is an open-access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) ). |
spellingShingle | Original Scientific Paper Jahani, Peyman Mohammadzadeh Jafari, Maedeh Ahmadi, Sayed Ali Voltammetric determination of vitamin B6 in the presence of vitamin C based on zinc ferrite nano-particles modified screen-printed graphite electrode |
title | Voltammetric determination of vitamin B6 in the presence of vitamin C based on zinc ferrite nano-particles modified screen-printed graphite electrode |
title_full | Voltammetric determination of vitamin B6 in the presence of vitamin C based on zinc ferrite nano-particles modified screen-printed graphite electrode |
title_fullStr | Voltammetric determination of vitamin B6 in the presence of vitamin C based on zinc ferrite nano-particles modified screen-printed graphite electrode |
title_full_unstemmed | Voltammetric determination of vitamin B6 in the presence of vitamin C based on zinc ferrite nano-particles modified screen-printed graphite electrode |
title_short | Voltammetric determination of vitamin B6 in the presence of vitamin C based on zinc ferrite nano-particles modified screen-printed graphite electrode |
title_sort | voltammetric determination of vitamin b6 in the presence of vitamin c based on zinc ferrite nano-particles modified screen-printed graphite electrode |
topic | Original Scientific Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10262225/ https://www.ncbi.nlm.nih.gov/pubmed/37325119 http://dx.doi.org/10.5599/admet.1702 |
work_keys_str_mv | AT jahanipeymanmohammadzadeh voltammetricdeterminationofvitaminb6inthepresenceofvitamincbasedonzincferritenanoparticlesmodifiedscreenprintedgraphiteelectrode AT jafarimaedeh voltammetricdeterminationofvitaminb6inthepresenceofvitamincbasedonzincferritenanoparticlesmodifiedscreenprintedgraphiteelectrode AT ahmadisayedali voltammetricdeterminationofvitaminb6inthepresenceofvitamincbasedonzincferritenanoparticlesmodifiedscreenprintedgraphiteelectrode |