Cargando…

Comparative Effect of No Finish Line, Heavy Chamfer, and Shoulder Marginal Designs on the Fracture Resistance of Zirconia (Cercon) Ceramic Restoration: An In Vitro Study

Background Because all-ceramic crowns are more aesthetic and biocompatible than metal-ceramic crowns, they have grown in popularity among patients and dentists. Poor finish line layout can result in restoration margin fracturing, hence, finish line arrangement is critical to maintaining the restorat...

Descripción completa

Detalles Bibliográficos
Autores principales: Gavara, Sai Govind, Jain, Shashikala, Gupta, Himanshu, Sharma, Suraj, Panwar, Pratibha, Momin, Mariyam S
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10264088/
https://www.ncbi.nlm.nih.gov/pubmed/37323304
http://dx.doi.org/10.7759/cureus.39009
_version_ 1785058255068725248
author Gavara, Sai Govind
Jain, Shashikala
Gupta, Himanshu
Sharma, Suraj
Panwar, Pratibha
Momin, Mariyam S
author_facet Gavara, Sai Govind
Jain, Shashikala
Gupta, Himanshu
Sharma, Suraj
Panwar, Pratibha
Momin, Mariyam S
author_sort Gavara, Sai Govind
collection PubMed
description Background Because all-ceramic crowns are more aesthetic and biocompatible than metal-ceramic crowns, they have grown in popularity among patients and dentists. Poor finish line layout can result in restoration margin fracturing, hence, finish line arrangement is critical to maintaining the restoration’s marginal integrity. The goal of this in-vitro study is to evaluate zirconia’s resistance to fracture (Cercon) ceramic restorations with three marginal designs (no finish line, heavy chamfer, and shoulder). This study is important in contributing to the ongoing debate about the optimal finish line design for zirconia restorations. Methodology Three different finish lines, namely, biologically oriented preparation technique (BOPT) with a marginal width of less than 0.3 mm, heavy chamfer with a marginal width of up to 0.3 mm, and shoulder with a marginal width greater than 0.3 mm, were made on 10 extracted maxillary first premolar tooth to make 30 epoxy resin dies on which zirconia (Cercon) coping was done using CAD/CAM technology, and marginal discrepancies were measured using a three-dimensional scanner. All the copings were affixed to their respective dies using GIC luting cement, and fracture resistance was measured using a digital universal testing machine. Results The Kruskal-Wallis test revealed that the mean fracture resistance was more in the heavy chamfer finish line, followed by the no finish line (BOPT) and the shoulder finish line. No statistically significant difference was seen between the no finish line and the heavy chamfer finish line. There was a significant difference between the heavy chamfer and shoulder finish lines (p = 0.004). Conclusions To increase the biomechanical performance of posterior single zirconia restorations, heavy chamfer margins are indicated.
format Online
Article
Text
id pubmed-10264088
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-102640882023-06-15 Comparative Effect of No Finish Line, Heavy Chamfer, and Shoulder Marginal Designs on the Fracture Resistance of Zirconia (Cercon) Ceramic Restoration: An In Vitro Study Gavara, Sai Govind Jain, Shashikala Gupta, Himanshu Sharma, Suraj Panwar, Pratibha Momin, Mariyam S Cureus Medical Education Background Because all-ceramic crowns are more aesthetic and biocompatible than metal-ceramic crowns, they have grown in popularity among patients and dentists. Poor finish line layout can result in restoration margin fracturing, hence, finish line arrangement is critical to maintaining the restoration’s marginal integrity. The goal of this in-vitro study is to evaluate zirconia’s resistance to fracture (Cercon) ceramic restorations with three marginal designs (no finish line, heavy chamfer, and shoulder). This study is important in contributing to the ongoing debate about the optimal finish line design for zirconia restorations. Methodology Three different finish lines, namely, biologically oriented preparation technique (BOPT) with a marginal width of less than 0.3 mm, heavy chamfer with a marginal width of up to 0.3 mm, and shoulder with a marginal width greater than 0.3 mm, were made on 10 extracted maxillary first premolar tooth to make 30 epoxy resin dies on which zirconia (Cercon) coping was done using CAD/CAM technology, and marginal discrepancies were measured using a three-dimensional scanner. All the copings were affixed to their respective dies using GIC luting cement, and fracture resistance was measured using a digital universal testing machine. Results The Kruskal-Wallis test revealed that the mean fracture resistance was more in the heavy chamfer finish line, followed by the no finish line (BOPT) and the shoulder finish line. No statistically significant difference was seen between the no finish line and the heavy chamfer finish line. There was a significant difference between the heavy chamfer and shoulder finish lines (p = 0.004). Conclusions To increase the biomechanical performance of posterior single zirconia restorations, heavy chamfer margins are indicated. Cureus 2023-05-14 /pmc/articles/PMC10264088/ /pubmed/37323304 http://dx.doi.org/10.7759/cureus.39009 Text en Copyright © 2023, Gavara et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Medical Education
Gavara, Sai Govind
Jain, Shashikala
Gupta, Himanshu
Sharma, Suraj
Panwar, Pratibha
Momin, Mariyam S
Comparative Effect of No Finish Line, Heavy Chamfer, and Shoulder Marginal Designs on the Fracture Resistance of Zirconia (Cercon) Ceramic Restoration: An In Vitro Study
title Comparative Effect of No Finish Line, Heavy Chamfer, and Shoulder Marginal Designs on the Fracture Resistance of Zirconia (Cercon) Ceramic Restoration: An In Vitro Study
title_full Comparative Effect of No Finish Line, Heavy Chamfer, and Shoulder Marginal Designs on the Fracture Resistance of Zirconia (Cercon) Ceramic Restoration: An In Vitro Study
title_fullStr Comparative Effect of No Finish Line, Heavy Chamfer, and Shoulder Marginal Designs on the Fracture Resistance of Zirconia (Cercon) Ceramic Restoration: An In Vitro Study
title_full_unstemmed Comparative Effect of No Finish Line, Heavy Chamfer, and Shoulder Marginal Designs on the Fracture Resistance of Zirconia (Cercon) Ceramic Restoration: An In Vitro Study
title_short Comparative Effect of No Finish Line, Heavy Chamfer, and Shoulder Marginal Designs on the Fracture Resistance of Zirconia (Cercon) Ceramic Restoration: An In Vitro Study
title_sort comparative effect of no finish line, heavy chamfer, and shoulder marginal designs on the fracture resistance of zirconia (cercon) ceramic restoration: an in vitro study
topic Medical Education
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10264088/
https://www.ncbi.nlm.nih.gov/pubmed/37323304
http://dx.doi.org/10.7759/cureus.39009
work_keys_str_mv AT gavarasaigovind comparativeeffectofnofinishlineheavychamferandshouldermarginaldesignsonthefractureresistanceofzirconiacerconceramicrestorationaninvitrostudy
AT jainshashikala comparativeeffectofnofinishlineheavychamferandshouldermarginaldesignsonthefractureresistanceofzirconiacerconceramicrestorationaninvitrostudy
AT guptahimanshu comparativeeffectofnofinishlineheavychamferandshouldermarginaldesignsonthefractureresistanceofzirconiacerconceramicrestorationaninvitrostudy
AT sharmasuraj comparativeeffectofnofinishlineheavychamferandshouldermarginaldesignsonthefractureresistanceofzirconiacerconceramicrestorationaninvitrostudy
AT panwarpratibha comparativeeffectofnofinishlineheavychamferandshouldermarginaldesignsonthefractureresistanceofzirconiacerconceramicrestorationaninvitrostudy
AT mominmariyams comparativeeffectofnofinishlineheavychamferandshouldermarginaldesignsonthefractureresistanceofzirconiacerconceramicrestorationaninvitrostudy