Cargando…

Impact of fracture‐prone implantable cardioverter defibrillator leads on long‐term patient mortality

BACKGROUND: The long‐term relationship between fracture‐prone implantable cardioverter‐defibrillator (ICD) leads and poor prognosis remains unclear in Japanese patients. METHODS: We conducted a retrospective review of the records of 445 patients who underwent implantation of advisory/Linox leads (Sp...

Descripción completa

Detalles Bibliográficos
Autores principales: Koike, Toshiharu, Shoda, Morio, Ejima, Koichiro, Yagishita, Daigo, Suzuki, Atsushi, Hasegawa, Shun, Kataoka, Shohei, Yazaki, Kyoichiro, Higuchi, Satoshi, Kanai, Miwa, Yamaguchi, Junichi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10264742/
https://www.ncbi.nlm.nih.gov/pubmed/37324755
http://dx.doi.org/10.1002/joa3.12843
Descripción
Sumario:BACKGROUND: The long‐term relationship between fracture‐prone implantable cardioverter‐defibrillator (ICD) leads and poor prognosis remains unclear in Japanese patients. METHODS: We conducted a retrospective review of the records of 445 patients who underwent implantation of advisory/Linox leads (Sprint Fidelis, 118; Riata, nine; Isoline, 10; Linox S/SD, 45) and non‐advisory leads (Endotak Reliance, 33; Durata, 199; Sprint non‐Fidelis, 31) between January 2005 and June 2012 at our hospital. The primary outcomes were all‐cause mortality and ICD lead failure. The secondary outcomes were cardiovascular mortality, heart failure (HF) hospitalization, and the composite outcome of cardiovascular mortality and HF hospitalization. RESULTS: During the follow‐up period (median, 8.6 [4.1–12.0] years), there were 152 deaths: 61 (34%) in patients with advisory/Linox leads and 91 (35%) in those with non‐advisory leads. There were 32 ICD lead failures: 27 (15%) in patients with advisory/Linox leads and five (2%) in those with non‐advisory leads. Multivariate analysis for ICD lead failure demonstrated that the advisory/Linox leads had a 6.65‐fold significantly greater risk of ICD lead failure than non‐advisory leads. Congenital heart disease (hazard ratio 2.51; 95% confidence interval 1.08–5.83; p = .03) could also independently predict ICD lead failure. Multivariate analysis for all‐cause mortality demonstrated no significant association between advisory/Linox leads and all‐cause mortality. CONCLUSIONS: Patients who have implanted fracture‐prone ICD leads should be carefully followed up for ICD lead failure. However, these patients have a long‐term survival rate comparable with that of patients with non‐advisory ICD leads in Japanese patients.