Cargando…
Remote vision testing of central retinal acuity and comparison with clinic-based Snellen acuity testing in patients followed for retinal conditions
INTRODUCTION: The unmet need for remote monitoring of visual function with home-based, patient-centric technologies became increasingly palpable during the COVID-19 pandemic. Many patients with chronic eye conditions lack access to office-based examinations. Here, we evaluate the efficacy of the Acc...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10265370/ https://www.ncbi.nlm.nih.gov/pubmed/37325078 http://dx.doi.org/10.1177/20552076231180727 |
Sumario: | INTRODUCTION: The unmet need for remote monitoring of visual function with home-based, patient-centric technologies became increasingly palpable during the COVID-19 pandemic. Many patients with chronic eye conditions lack access to office-based examinations. Here, we evaluate the efficacy of the Accustat® test, a virtual application for measuring near visual acuity on any portable electronic device via telehealth. MATERIALS AND METHODS: Thirty-three adult subjects from the telehealth remote monitoring service of a retina practice performed the Accustat® acuity testing at home. All patients underwent in-office general eye examination with additional fundoscopic examination and optical coherence tomography retina imaging. Best corrected visual acuity assessment using a Snellen chart was compared with remote visual acuity assessment with the Accustat® test. Visual acuity was analyzed and compared between the best-corrected near visual acuity potential achieved on the Accustat® and in-office distance best-corrected Snellen visual acuity. RESULTS: The mean logarithm of the minimum angle of resolution (logMAR) visual acuities of all eyes tested using the Accustat test was 0.19 ± 024 and for the office Snellen test 0.21 ± 0.21. A linear regression model with 95% confidence intervals reveals that there is a strong linear relationship between Accustat logMAR and office Snellen logMAR. Bland–Altman analysis demonstrated 95.2% significant agreement between Accustat and Office Snellen’s best corrected visual acuity. Intraclass correlation coefficient (ICC = 0.94) demonstrated a strong positive correlation between at home versus office visual acuity. CONCLUSION: There was a high correlation between the visual acuity measured with the Accustat near vision digital self-test and the office Snellen acuity test, suggesting the potential utility of scalable remote monitoring of central retinal function via telehealth. |
---|