Cargando…
Comparison of bispectral index and patient state index as measures of sedation depth during surgeries using remimazolam tosilate
BACKGROUND: The Bispectral Index (BIS) and the Patient State Index (PSI) are commonly used measures to assess intraoperative sedation depth. However, model differences lead to different results, which in turn interferes with clinicians’ judgment on the depth of anesthesia. Remimazolam tosilate (RT)...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10268360/ https://www.ncbi.nlm.nih.gov/pubmed/37322424 http://dx.doi.org/10.1186/s12871-023-02172-3 |
_version_ | 1785059076165599232 |
---|---|
author | Zhao, Tang-yuan-meng Chen, Di Xu, Zhi-xin Wang, Huan-liang Sun, Hu |
author_facet | Zhao, Tang-yuan-meng Chen, Di Xu, Zhi-xin Wang, Huan-liang Sun, Hu |
author_sort | Zhao, Tang-yuan-meng |
collection | PubMed |
description | BACKGROUND: The Bispectral Index (BIS) and the Patient State Index (PSI) are commonly used measures to assess intraoperative sedation depth. However, model differences lead to different results, which in turn interferes with clinicians’ judgment on the depth of anesthesia. Remimazolam tosilate (RT) for injection is a new benzodiazepine used in sedation. In its clinical application, there are few effective indicators for sedation depth monitoring. To close this gap, this study aims to compare BIS and PSI in measuring the sensitivity and specificity of intraoperative RT and to explore the safety of RT for intraspinal anesthesia in elderly patients. METHODS: This study included 40 patients undergoing elective electro-prostatectomy with intraspinal anesthesia, who were monitored by BIS and PSI simultaneously during operation. Remimazolam tosylate 0.1 mg/kg was intravenously administered after the intraspinal anesthesia when patients were in a completely painless status. Then BIS, PSI, the Modified Observer’s Assessment of Alertness and Sedation (MOAA/S) scores and vital signs were observed and recorded per minute for 10 min. Pearson’s correlation analysis and linear regression model were used to compare BIS and PSI sedation scores, and to test their associations with the MOAA/S score, respectively. ROC curves were drawn to compare the sensitivity and specificity of BIS and PSI. Changes of vital signs were presented as mean ± standard deviation. Perioperative liver and kidney function indicators were analyzed using a paired t-test to evaluate the safety of RT for intraspinal anesthesia in the elderly patients. RESULTS: According to Pearson’s correlation analysis, a significant (P < 0.01) correlation between BIS and PSI was found when used to monitor intraoperative sedation of RT (r = 0.796). Significant associations between BIS and MOAA/S (r = 0.568, P < 0.01), and between PSI and MOAA/S (r = 0.390, P < 0.01) were also found. The areas under the ROC curves of BIS and PSI were 0.801 ± 0.022 and 0.734 ± 0.026, respectively, suggesting that both measures may predict patients’ state of consciousness and BIS was more accurate than PSI. Vital signs remained stable throughout the study. No abnormal changes of clinical significance were found based on laboratory test results of liver and kidney function. CONCLUSION: BIS and PSI are strongly associated for monitoring the sedation of RT intraoperatively. Both methods can accurately reflect sedation depth. According to correlation analyses with MOAA/S scale and ROC curves, BIS is more accurate than PSI during such intraoperative monitoring. In addition, RT can be safely used in elderly patients under intraspinal anesthesia for supportive sedation, with stable vital signs and sound kidney and liver safety profiles. TRIAL REGISTRATION: http://www.chictr.org.cn (ChiCTR2100051912). SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12871-023-02172-3. |
format | Online Article Text |
id | pubmed-10268360 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-102683602023-06-15 Comparison of bispectral index and patient state index as measures of sedation depth during surgeries using remimazolam tosilate Zhao, Tang-yuan-meng Chen, Di Xu, Zhi-xin Wang, Huan-liang Sun, Hu BMC Anesthesiol Research BACKGROUND: The Bispectral Index (BIS) and the Patient State Index (PSI) are commonly used measures to assess intraoperative sedation depth. However, model differences lead to different results, which in turn interferes with clinicians’ judgment on the depth of anesthesia. Remimazolam tosilate (RT) for injection is a new benzodiazepine used in sedation. In its clinical application, there are few effective indicators for sedation depth monitoring. To close this gap, this study aims to compare BIS and PSI in measuring the sensitivity and specificity of intraoperative RT and to explore the safety of RT for intraspinal anesthesia in elderly patients. METHODS: This study included 40 patients undergoing elective electro-prostatectomy with intraspinal anesthesia, who were monitored by BIS and PSI simultaneously during operation. Remimazolam tosylate 0.1 mg/kg was intravenously administered after the intraspinal anesthesia when patients were in a completely painless status. Then BIS, PSI, the Modified Observer’s Assessment of Alertness and Sedation (MOAA/S) scores and vital signs were observed and recorded per minute for 10 min. Pearson’s correlation analysis and linear regression model were used to compare BIS and PSI sedation scores, and to test their associations with the MOAA/S score, respectively. ROC curves were drawn to compare the sensitivity and specificity of BIS and PSI. Changes of vital signs were presented as mean ± standard deviation. Perioperative liver and kidney function indicators were analyzed using a paired t-test to evaluate the safety of RT for intraspinal anesthesia in the elderly patients. RESULTS: According to Pearson’s correlation analysis, a significant (P < 0.01) correlation between BIS and PSI was found when used to monitor intraoperative sedation of RT (r = 0.796). Significant associations between BIS and MOAA/S (r = 0.568, P < 0.01), and between PSI and MOAA/S (r = 0.390, P < 0.01) were also found. The areas under the ROC curves of BIS and PSI were 0.801 ± 0.022 and 0.734 ± 0.026, respectively, suggesting that both measures may predict patients’ state of consciousness and BIS was more accurate than PSI. Vital signs remained stable throughout the study. No abnormal changes of clinical significance were found based on laboratory test results of liver and kidney function. CONCLUSION: BIS and PSI are strongly associated for monitoring the sedation of RT intraoperatively. Both methods can accurately reflect sedation depth. According to correlation analyses with MOAA/S scale and ROC curves, BIS is more accurate than PSI during such intraoperative monitoring. In addition, RT can be safely used in elderly patients under intraspinal anesthesia for supportive sedation, with stable vital signs and sound kidney and liver safety profiles. TRIAL REGISTRATION: http://www.chictr.org.cn (ChiCTR2100051912). SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12871-023-02172-3. BioMed Central 2023-06-15 /pmc/articles/PMC10268360/ /pubmed/37322424 http://dx.doi.org/10.1186/s12871-023-02172-3 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Zhao, Tang-yuan-meng Chen, Di Xu, Zhi-xin Wang, Huan-liang Sun, Hu Comparison of bispectral index and patient state index as measures of sedation depth during surgeries using remimazolam tosilate |
title | Comparison of bispectral index and patient state index as measures of sedation depth during surgeries using remimazolam tosilate |
title_full | Comparison of bispectral index and patient state index as measures of sedation depth during surgeries using remimazolam tosilate |
title_fullStr | Comparison of bispectral index and patient state index as measures of sedation depth during surgeries using remimazolam tosilate |
title_full_unstemmed | Comparison of bispectral index and patient state index as measures of sedation depth during surgeries using remimazolam tosilate |
title_short | Comparison of bispectral index and patient state index as measures of sedation depth during surgeries using remimazolam tosilate |
title_sort | comparison of bispectral index and patient state index as measures of sedation depth during surgeries using remimazolam tosilate |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10268360/ https://www.ncbi.nlm.nih.gov/pubmed/37322424 http://dx.doi.org/10.1186/s12871-023-02172-3 |
work_keys_str_mv | AT zhaotangyuanmeng comparisonofbispectralindexandpatientstateindexasmeasuresofsedationdepthduringsurgeriesusingremimazolamtosilate AT chendi comparisonofbispectralindexandpatientstateindexasmeasuresofsedationdepthduringsurgeriesusingremimazolamtosilate AT xuzhixin comparisonofbispectralindexandpatientstateindexasmeasuresofsedationdepthduringsurgeriesusingremimazolamtosilate AT wanghuanliang comparisonofbispectralindexandpatientstateindexasmeasuresofsedationdepthduringsurgeriesusingremimazolamtosilate AT sunhu comparisonofbispectralindexandpatientstateindexasmeasuresofsedationdepthduringsurgeriesusingremimazolamtosilate |