Cargando…

Comparison of Modified Manual Acid-Phenol Chloroform Method and Commercial RNA Extraction Kits for Resource Limited Laboratories

METHOD: In a comparative experimental cross-sectional study, RNA was extracted from oral swabs and blood samples from 25 healthy individuals at the Department of Molecular Medicine, KNUST. RNA was extracted by the manual AGPC extraction method and commercial RNA extraction kits. The quantity (ng/μl)...

Descripción completa

Detalles Bibliográficos
Autores principales: Sakyi, Samuel Asamoah, Effah, Alfred, Naturinda, Emmanuel, Senu, Ebenezer, Opoku, Stephen, Amoani, Benjamin, Agordzo, Samuel Kekeli, Mensah, Oscar Simon Olympio, Grant, James, Abban, Elizabeth, Buckman, Tonnies Abeku, Kwarteng, Alexander, Ephraim, Richard K. Dadzie, Danquah, Kwabena Owusu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10275685/
https://www.ncbi.nlm.nih.gov/pubmed/37333947
http://dx.doi.org/10.1155/2023/9593796
_version_ 1785059919689416704
author Sakyi, Samuel Asamoah
Effah, Alfred
Naturinda, Emmanuel
Senu, Ebenezer
Opoku, Stephen
Amoani, Benjamin
Agordzo, Samuel Kekeli
Mensah, Oscar Simon Olympio
Grant, James
Abban, Elizabeth
Buckman, Tonnies Abeku
Kwarteng, Alexander
Ephraim, Richard K. Dadzie
Danquah, Kwabena Owusu
author_facet Sakyi, Samuel Asamoah
Effah, Alfred
Naturinda, Emmanuel
Senu, Ebenezer
Opoku, Stephen
Amoani, Benjamin
Agordzo, Samuel Kekeli
Mensah, Oscar Simon Olympio
Grant, James
Abban, Elizabeth
Buckman, Tonnies Abeku
Kwarteng, Alexander
Ephraim, Richard K. Dadzie
Danquah, Kwabena Owusu
author_sort Sakyi, Samuel Asamoah
collection PubMed
description METHOD: In a comparative experimental cross-sectional study, RNA was extracted from oral swabs and blood samples from 25 healthy individuals at the Department of Molecular Medicine, KNUST. RNA was extracted by the manual AGPC extraction method and commercial RNA extraction kits. The quantity (ng/μl) and purities (260/280 nm) of the extracted RNA were measured spectrophotometrically using the IMPLEN NanoPhotometer® N60. The presence of RNA in the extracts was confirmed using 2% agarose gel electrophoresis. Statistical analyses were conducted using R language. RESULTS: The yield of RNA extracted from blood and oral swab samples using modified AGPC was significantly higher compared to the commercial methods (p < 0.0001). However, the purity of RNA extracted by the manual AGPC method from blood was significantly lower than the commercial methods (p < 0.0001). Moreover, the purity from oral swabs using the manual AGPC method was significantly lower compared to QIAamp (p < 0.0001) and the OxGEn kits method (p < 0.001). CONCLUSION: The modified manual AGPC method has a very high yield of RNA extracts using blood samples, which could serve as an alternate cost-effective method for RNA extraction in resource-limited laboratories; however, its purity may not be suitable for downstream processes. Moreover, the manual AGPC method may not be suitable for extracting RNA from oral swab samples. Future investigation is needed to improve the purity of the manual AGPC RNA extraction method and also confirmation of the obtained results by PCR amplification and RNA purity verification by sequencing.
format Online
Article
Text
id pubmed-10275685
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-102756852023-06-17 Comparison of Modified Manual Acid-Phenol Chloroform Method and Commercial RNA Extraction Kits for Resource Limited Laboratories Sakyi, Samuel Asamoah Effah, Alfred Naturinda, Emmanuel Senu, Ebenezer Opoku, Stephen Amoani, Benjamin Agordzo, Samuel Kekeli Mensah, Oscar Simon Olympio Grant, James Abban, Elizabeth Buckman, Tonnies Abeku Kwarteng, Alexander Ephraim, Richard K. Dadzie Danquah, Kwabena Owusu Int J Clin Pract Research Article METHOD: In a comparative experimental cross-sectional study, RNA was extracted from oral swabs and blood samples from 25 healthy individuals at the Department of Molecular Medicine, KNUST. RNA was extracted by the manual AGPC extraction method and commercial RNA extraction kits. The quantity (ng/μl) and purities (260/280 nm) of the extracted RNA were measured spectrophotometrically using the IMPLEN NanoPhotometer® N60. The presence of RNA in the extracts was confirmed using 2% agarose gel electrophoresis. Statistical analyses were conducted using R language. RESULTS: The yield of RNA extracted from blood and oral swab samples using modified AGPC was significantly higher compared to the commercial methods (p < 0.0001). However, the purity of RNA extracted by the manual AGPC method from blood was significantly lower than the commercial methods (p < 0.0001). Moreover, the purity from oral swabs using the manual AGPC method was significantly lower compared to QIAamp (p < 0.0001) and the OxGEn kits method (p < 0.001). CONCLUSION: The modified manual AGPC method has a very high yield of RNA extracts using blood samples, which could serve as an alternate cost-effective method for RNA extraction in resource-limited laboratories; however, its purity may not be suitable for downstream processes. Moreover, the manual AGPC method may not be suitable for extracting RNA from oral swab samples. Future investigation is needed to improve the purity of the manual AGPC RNA extraction method and also confirmation of the obtained results by PCR amplification and RNA purity verification by sequencing. Hindawi 2023-06-09 /pmc/articles/PMC10275685/ /pubmed/37333947 http://dx.doi.org/10.1155/2023/9593796 Text en Copyright © 2023 Samuel Asamoah Sakyi et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Sakyi, Samuel Asamoah
Effah, Alfred
Naturinda, Emmanuel
Senu, Ebenezer
Opoku, Stephen
Amoani, Benjamin
Agordzo, Samuel Kekeli
Mensah, Oscar Simon Olympio
Grant, James
Abban, Elizabeth
Buckman, Tonnies Abeku
Kwarteng, Alexander
Ephraim, Richard K. Dadzie
Danquah, Kwabena Owusu
Comparison of Modified Manual Acid-Phenol Chloroform Method and Commercial RNA Extraction Kits for Resource Limited Laboratories
title Comparison of Modified Manual Acid-Phenol Chloroform Method and Commercial RNA Extraction Kits for Resource Limited Laboratories
title_full Comparison of Modified Manual Acid-Phenol Chloroform Method and Commercial RNA Extraction Kits for Resource Limited Laboratories
title_fullStr Comparison of Modified Manual Acid-Phenol Chloroform Method and Commercial RNA Extraction Kits for Resource Limited Laboratories
title_full_unstemmed Comparison of Modified Manual Acid-Phenol Chloroform Method and Commercial RNA Extraction Kits for Resource Limited Laboratories
title_short Comparison of Modified Manual Acid-Phenol Chloroform Method and Commercial RNA Extraction Kits for Resource Limited Laboratories
title_sort comparison of modified manual acid-phenol chloroform method and commercial rna extraction kits for resource limited laboratories
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10275685/
https://www.ncbi.nlm.nih.gov/pubmed/37333947
http://dx.doi.org/10.1155/2023/9593796
work_keys_str_mv AT sakyisamuelasamoah comparisonofmodifiedmanualacidphenolchloroformmethodandcommercialrnaextractionkitsforresourcelimitedlaboratories
AT effahalfred comparisonofmodifiedmanualacidphenolchloroformmethodandcommercialrnaextractionkitsforresourcelimitedlaboratories
AT naturindaemmanuel comparisonofmodifiedmanualacidphenolchloroformmethodandcommercialrnaextractionkitsforresourcelimitedlaboratories
AT senuebenezer comparisonofmodifiedmanualacidphenolchloroformmethodandcommercialrnaextractionkitsforresourcelimitedlaboratories
AT opokustephen comparisonofmodifiedmanualacidphenolchloroformmethodandcommercialrnaextractionkitsforresourcelimitedlaboratories
AT amoanibenjamin comparisonofmodifiedmanualacidphenolchloroformmethodandcommercialrnaextractionkitsforresourcelimitedlaboratories
AT agordzosamuelkekeli comparisonofmodifiedmanualacidphenolchloroformmethodandcommercialrnaextractionkitsforresourcelimitedlaboratories
AT mensahoscarsimonolympio comparisonofmodifiedmanualacidphenolchloroformmethodandcommercialrnaextractionkitsforresourcelimitedlaboratories
AT grantjames comparisonofmodifiedmanualacidphenolchloroformmethodandcommercialrnaextractionkitsforresourcelimitedlaboratories
AT abbanelizabeth comparisonofmodifiedmanualacidphenolchloroformmethodandcommercialrnaextractionkitsforresourcelimitedlaboratories
AT buckmantonniesabeku comparisonofmodifiedmanualacidphenolchloroformmethodandcommercialrnaextractionkitsforresourcelimitedlaboratories
AT kwartengalexander comparisonofmodifiedmanualacidphenolchloroformmethodandcommercialrnaextractionkitsforresourcelimitedlaboratories
AT ephraimrichardkdadzie comparisonofmodifiedmanualacidphenolchloroformmethodandcommercialrnaextractionkitsforresourcelimitedlaboratories
AT danquahkwabenaowusu comparisonofmodifiedmanualacidphenolchloroformmethodandcommercialrnaextractionkitsforresourcelimitedlaboratories