Cargando…
Integration of statistical shape modeling and alternating interpolation-based model tracking technique for measuring knee kinematics in vivo using clinical interleaved bi-plane fluoroscopy
BACKGROUND: A 2D fluoroscopy/3D model-based registration with statistical shape modeling (SSM)-reconstructed subject-specific bone models will help reduce radiation exposure for 3D kinematic measurements of the knee using clinical alternating bi-plane fluoroscopy systems. The current study aimed to...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
PeerJ Inc.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10276557/ https://www.ncbi.nlm.nih.gov/pubmed/37334125 http://dx.doi.org/10.7717/peerj.15371 |
_version_ | 1785060104417050624 |
---|---|
author | Lu, Hsuan-Yu Lin, Cheng-Chung Shih, Kao-Shang Lu, Tung-Wu Kuo, Mei-Ying Li, Song-Ying Hsu, Horng-Chaung |
author_facet | Lu, Hsuan-Yu Lin, Cheng-Chung Shih, Kao-Shang Lu, Tung-Wu Kuo, Mei-Ying Li, Song-Ying Hsu, Horng-Chaung |
author_sort | Lu, Hsuan-Yu |
collection | PubMed |
description | BACKGROUND: A 2D fluoroscopy/3D model-based registration with statistical shape modeling (SSM)-reconstructed subject-specific bone models will help reduce radiation exposure for 3D kinematic measurements of the knee using clinical alternating bi-plane fluoroscopy systems. The current study aimed to develop such an approach and evaluate in vivo its accuracy and identify the effects of the accuracy of SSM models on the kinematic measurements. METHODS: An alternating interpolation-based model tracking (AIMT) approach with SSM-reconstructed subject-specific bone models was used for measuring 3D knee kinematics from dynamic alternating bi-plane fluoroscopy images. A two-phase optimization scheme was used to reconstruct subject-specific knee models from a CT-based SSM database of 60 knees using one, two, or three pairs of fluoroscopy images. Using the CT-reconstructed model as a benchmark, the performance of the AIMT with SSM-reconstructed models in measuring bone and joint kinematics during dynamic activity was evaluated in terms of mean target registration errors (mmTRE) for registered bone poses and the mean absolute differences (MAD) for each motion component of the joint poses. RESULTS: The mmTRE of the femur and tibia for one image pair were significantly greater than those for two and three image pairs without significant differences between two and three image pairs. The MAD was 1.16 to 1.22° for rotations and 1.18 to 1.22 mm for translations using one image pair. The corresponding values for two and three image pairs were 0.75 to 0.89° and 0.75 to 0.79 mm; and 0.57 to 0.79° and 0.6 to 0.69 mm, respectively. The MAD values for one image pair were significantly greater than those for two and three image pairs without significant differences between two and three image pairs. CONCLUSIONS: An AIMT approach with SSM-reconstructed models was developed, enabling the registration of interleaved fluoroscopy images and SSM-reconstructed models from more than one asynchronous fluoroscopy image pair. This new approach had sub-millimeter and sub-degree measurement accuracy when using more than one image pair, comparable to the accuracy of CT-based methods. This approach will be helpful for future kinematic measurements of the knee with reduced radiation exposure using 3D fluoroscopy with clinically alternating bi-plane fluoroscopy systems. |
format | Online Article Text |
id | pubmed-10276557 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | PeerJ Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-102765572023-06-18 Integration of statistical shape modeling and alternating interpolation-based model tracking technique for measuring knee kinematics in vivo using clinical interleaved bi-plane fluoroscopy Lu, Hsuan-Yu Lin, Cheng-Chung Shih, Kao-Shang Lu, Tung-Wu Kuo, Mei-Ying Li, Song-Ying Hsu, Horng-Chaung PeerJ Kinesiology BACKGROUND: A 2D fluoroscopy/3D model-based registration with statistical shape modeling (SSM)-reconstructed subject-specific bone models will help reduce radiation exposure for 3D kinematic measurements of the knee using clinical alternating bi-plane fluoroscopy systems. The current study aimed to develop such an approach and evaluate in vivo its accuracy and identify the effects of the accuracy of SSM models on the kinematic measurements. METHODS: An alternating interpolation-based model tracking (AIMT) approach with SSM-reconstructed subject-specific bone models was used for measuring 3D knee kinematics from dynamic alternating bi-plane fluoroscopy images. A two-phase optimization scheme was used to reconstruct subject-specific knee models from a CT-based SSM database of 60 knees using one, two, or three pairs of fluoroscopy images. Using the CT-reconstructed model as a benchmark, the performance of the AIMT with SSM-reconstructed models in measuring bone and joint kinematics during dynamic activity was evaluated in terms of mean target registration errors (mmTRE) for registered bone poses and the mean absolute differences (MAD) for each motion component of the joint poses. RESULTS: The mmTRE of the femur and tibia for one image pair were significantly greater than those for two and three image pairs without significant differences between two and three image pairs. The MAD was 1.16 to 1.22° for rotations and 1.18 to 1.22 mm for translations using one image pair. The corresponding values for two and three image pairs were 0.75 to 0.89° and 0.75 to 0.79 mm; and 0.57 to 0.79° and 0.6 to 0.69 mm, respectively. The MAD values for one image pair were significantly greater than those for two and three image pairs without significant differences between two and three image pairs. CONCLUSIONS: An AIMT approach with SSM-reconstructed models was developed, enabling the registration of interleaved fluoroscopy images and SSM-reconstructed models from more than one asynchronous fluoroscopy image pair. This new approach had sub-millimeter and sub-degree measurement accuracy when using more than one image pair, comparable to the accuracy of CT-based methods. This approach will be helpful for future kinematic measurements of the knee with reduced radiation exposure using 3D fluoroscopy with clinically alternating bi-plane fluoroscopy systems. PeerJ Inc. 2023-06-14 /pmc/articles/PMC10276557/ /pubmed/37334125 http://dx.doi.org/10.7717/peerj.15371 Text en ©2023 Lu et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, reproduction and adaptation in any medium and for any purpose provided that it is properly attributed. For attribution, the original author(s), title, publication source (PeerJ) and either DOI or URL of the article must be cited. |
spellingShingle | Kinesiology Lu, Hsuan-Yu Lin, Cheng-Chung Shih, Kao-Shang Lu, Tung-Wu Kuo, Mei-Ying Li, Song-Ying Hsu, Horng-Chaung Integration of statistical shape modeling and alternating interpolation-based model tracking technique for measuring knee kinematics in vivo using clinical interleaved bi-plane fluoroscopy |
title | Integration of statistical shape modeling and alternating interpolation-based model tracking technique for measuring knee kinematics in vivo using clinical interleaved bi-plane fluoroscopy |
title_full | Integration of statistical shape modeling and alternating interpolation-based model tracking technique for measuring knee kinematics in vivo using clinical interleaved bi-plane fluoroscopy |
title_fullStr | Integration of statistical shape modeling and alternating interpolation-based model tracking technique for measuring knee kinematics in vivo using clinical interleaved bi-plane fluoroscopy |
title_full_unstemmed | Integration of statistical shape modeling and alternating interpolation-based model tracking technique for measuring knee kinematics in vivo using clinical interleaved bi-plane fluoroscopy |
title_short | Integration of statistical shape modeling and alternating interpolation-based model tracking technique for measuring knee kinematics in vivo using clinical interleaved bi-plane fluoroscopy |
title_sort | integration of statistical shape modeling and alternating interpolation-based model tracking technique for measuring knee kinematics in vivo using clinical interleaved bi-plane fluoroscopy |
topic | Kinesiology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10276557/ https://www.ncbi.nlm.nih.gov/pubmed/37334125 http://dx.doi.org/10.7717/peerj.15371 |
work_keys_str_mv | AT luhsuanyu integrationofstatisticalshapemodelingandalternatinginterpolationbasedmodeltrackingtechniqueformeasuringkneekinematicsinvivousingclinicalinterleavedbiplanefluoroscopy AT linchengchung integrationofstatisticalshapemodelingandalternatinginterpolationbasedmodeltrackingtechniqueformeasuringkneekinematicsinvivousingclinicalinterleavedbiplanefluoroscopy AT shihkaoshang integrationofstatisticalshapemodelingandalternatinginterpolationbasedmodeltrackingtechniqueformeasuringkneekinematicsinvivousingclinicalinterleavedbiplanefluoroscopy AT lutungwu integrationofstatisticalshapemodelingandalternatinginterpolationbasedmodeltrackingtechniqueformeasuringkneekinematicsinvivousingclinicalinterleavedbiplanefluoroscopy AT kuomeiying integrationofstatisticalshapemodelingandalternatinginterpolationbasedmodeltrackingtechniqueformeasuringkneekinematicsinvivousingclinicalinterleavedbiplanefluoroscopy AT lisongying integrationofstatisticalshapemodelingandalternatinginterpolationbasedmodeltrackingtechniqueformeasuringkneekinematicsinvivousingclinicalinterleavedbiplanefluoroscopy AT hsuhorngchaung integrationofstatisticalshapemodelingandalternatinginterpolationbasedmodeltrackingtechniqueformeasuringkneekinematicsinvivousingclinicalinterleavedbiplanefluoroscopy |