Cargando…

Deep Inspiratory Breath-Hold Radiation for Left-Sided Breast Cancer using Novel Frame-based Tactile Feedback

A frame providing tactile feedback for the reproducibility of deep inspiratory breath-hold (DIBH) is described. The frame, fitted across the patient, comprises a horizontal bar, parallel to the patient’s long axis, and holds a graduated pointer perpendicular to it. The pointer provides individualize...

Descripción completa

Detalles Bibliográficos
Autores principales: Nangia, Sapna, Khosa, Robin, Piyushi, Divya, Singh, Maneesh, Singh, Grishma, Sreedevi, K., Chauhan, Sunil Kumar, Rout, Sanjay Kumar, Oomen, Saji
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10277295/
https://www.ncbi.nlm.nih.gov/pubmed/37342598
http://dx.doi.org/10.4103/jmp.jmp_79_22
_version_ 1785060249276776448
author Nangia, Sapna
Khosa, Robin
Piyushi, Divya
Singh, Maneesh
Singh, Grishma
Sreedevi, K.
Chauhan, Sunil Kumar
Rout, Sanjay Kumar
Oomen, Saji
author_facet Nangia, Sapna
Khosa, Robin
Piyushi, Divya
Singh, Maneesh
Singh, Grishma
Sreedevi, K.
Chauhan, Sunil Kumar
Rout, Sanjay Kumar
Oomen, Saji
author_sort Nangia, Sapna
collection PubMed
description A frame providing tactile feedback for the reproducibility of deep inspiratory breath-hold (DIBH) is described. The frame, fitted across the patient, comprises a horizontal bar, parallel to the patient’s long axis, and holds a graduated pointer perpendicular to it. The pointer provides individualized tactile feedback for reproducibility of DIBH. Within the pointer is a movable pencil, bearing a 5 mm coloured strip which becomes visible only during DIBH, and acts as a visual cue to the therapist. The average variation in separation in the planning and pretreatment cone-beam computed tomography of 10 patients was 2 mm (confidence interval 1.95–2.05). Frame-based tactile feedback is a novel, reproducible technique for DIBH.
format Online
Article
Text
id pubmed-10277295
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-102772952023-06-20 Deep Inspiratory Breath-Hold Radiation for Left-Sided Breast Cancer using Novel Frame-based Tactile Feedback Nangia, Sapna Khosa, Robin Piyushi, Divya Singh, Maneesh Singh, Grishma Sreedevi, K. Chauhan, Sunil Kumar Rout, Sanjay Kumar Oomen, Saji J Med Phys Technical Note A frame providing tactile feedback for the reproducibility of deep inspiratory breath-hold (DIBH) is described. The frame, fitted across the patient, comprises a horizontal bar, parallel to the patient’s long axis, and holds a graduated pointer perpendicular to it. The pointer provides individualized tactile feedback for reproducibility of DIBH. Within the pointer is a movable pencil, bearing a 5 mm coloured strip which becomes visible only during DIBH, and acts as a visual cue to the therapist. The average variation in separation in the planning and pretreatment cone-beam computed tomography of 10 patients was 2 mm (confidence interval 1.95–2.05). Frame-based tactile feedback is a novel, reproducible technique for DIBH. Wolters Kluwer - Medknow 2023 2023-04-18 /pmc/articles/PMC10277295/ /pubmed/37342598 http://dx.doi.org/10.4103/jmp.jmp_79_22 Text en Copyright: © 2023 Journal of Medical Physics https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Technical Note
Nangia, Sapna
Khosa, Robin
Piyushi, Divya
Singh, Maneesh
Singh, Grishma
Sreedevi, K.
Chauhan, Sunil Kumar
Rout, Sanjay Kumar
Oomen, Saji
Deep Inspiratory Breath-Hold Radiation for Left-Sided Breast Cancer using Novel Frame-based Tactile Feedback
title Deep Inspiratory Breath-Hold Radiation for Left-Sided Breast Cancer using Novel Frame-based Tactile Feedback
title_full Deep Inspiratory Breath-Hold Radiation for Left-Sided Breast Cancer using Novel Frame-based Tactile Feedback
title_fullStr Deep Inspiratory Breath-Hold Radiation for Left-Sided Breast Cancer using Novel Frame-based Tactile Feedback
title_full_unstemmed Deep Inspiratory Breath-Hold Radiation for Left-Sided Breast Cancer using Novel Frame-based Tactile Feedback
title_short Deep Inspiratory Breath-Hold Radiation for Left-Sided Breast Cancer using Novel Frame-based Tactile Feedback
title_sort deep inspiratory breath-hold radiation for left-sided breast cancer using novel frame-based tactile feedback
topic Technical Note
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10277295/
https://www.ncbi.nlm.nih.gov/pubmed/37342598
http://dx.doi.org/10.4103/jmp.jmp_79_22
work_keys_str_mv AT nangiasapna deepinspiratorybreathholdradiationforleftsidedbreastcancerusingnovelframebasedtactilefeedback
AT khosarobin deepinspiratorybreathholdradiationforleftsidedbreastcancerusingnovelframebasedtactilefeedback
AT piyushidivya deepinspiratorybreathholdradiationforleftsidedbreastcancerusingnovelframebasedtactilefeedback
AT singhmaneesh deepinspiratorybreathholdradiationforleftsidedbreastcancerusingnovelframebasedtactilefeedback
AT singhgrishma deepinspiratorybreathholdradiationforleftsidedbreastcancerusingnovelframebasedtactilefeedback
AT sreedevik deepinspiratorybreathholdradiationforleftsidedbreastcancerusingnovelframebasedtactilefeedback
AT chauhansunilkumar deepinspiratorybreathholdradiationforleftsidedbreastcancerusingnovelframebasedtactilefeedback
AT routsanjaykumar deepinspiratorybreathholdradiationforleftsidedbreastcancerusingnovelframebasedtactilefeedback
AT oomensaji deepinspiratorybreathholdradiationforleftsidedbreastcancerusingnovelframebasedtactilefeedback