Cargando…
K(trans) Calculation Using Reference Method Corrected Native T(10) for Breast Cancer Diagnosis
PURPOSE: The objective of the study is to use multiple tube phantoms to generate correction factor at different spatial locations for each breast coil cuff to correct the native T(10) value in the corresponding spatial location of the breast lesion. The corrected T(10) value was used to compute K(tr...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10277302/ https://www.ncbi.nlm.nih.gov/pubmed/37342602 http://dx.doi.org/10.4103/jmp.jmp_90_22 |
_version_ | 1785060250973372416 |
---|---|
author | Negi, Pradeep Singh Mehta, Shashi Bhushan Jena, Amarnath Rana, Prerana |
author_facet | Negi, Pradeep Singh Mehta, Shashi Bhushan Jena, Amarnath Rana, Prerana |
author_sort | Negi, Pradeep Singh |
collection | PubMed |
description | PURPOSE: The objective of the study is to use multiple tube phantoms to generate correction factor at different spatial locations for each breast coil cuff to correct the native T(10) value in the corresponding spatial location of the breast lesion. The corrected T(10) value was used to compute K(trans) and analyze its diagnostic accuracy in the classification of target condition, i.e., breast tumors into malignant and benign. MATERIALS AND METHODS: Both in vitro phantom study (external reference) and patient’s studies were acquired on simultaneous positron emission tomography/magnetic resonance imaging (PET/MRI) Biograph molecular magnetic resonance (mMR) system using 4 channel mMR breast coil. The spatial correction factors derived using multiple tube phantom were used for a retrospective analysis of dynamic contrast-enhanced (DCE) MRI data of 39 patients with a mean age of 50 years (31–77 years) having 51 enhancing breast lesions. RESULTS: Corrected and non-corrected receiver operating characteristic (ROC) curve analysis revealed a mean K(trans) value of 0.64 min(−1) and 0.60 min(−1), respectively. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and overall accuracy for non-corrected data were 86.21%, 81.82%, 86.20%, 81.81%, and 84.31%, respectively, and for corrected data were 93.10%, 86.36%, 90%, 90.47%, and 90.20% respectively. The area under curve (AUC) of corrected data was improved to 0.959 (95% confidence interval [CI] 0.862–0.994) from 0.824 (95% CI 0.694–0.918) of non-corrected data, and for NPV, it was improved to 90.47% from 81.81%, respectively. CONCLUSION: T(10) values were normalized using multiple tube phantom which was used for computation of K(trans). We found significant improvement in the diagnostic accuracy of corrected K(trans) values that results in better characterization of breast lesions. |
format | Online Article Text |
id | pubmed-10277302 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-102773022023-06-20 K(trans) Calculation Using Reference Method Corrected Native T(10) for Breast Cancer Diagnosis Negi, Pradeep Singh Mehta, Shashi Bhushan Jena, Amarnath Rana, Prerana J Med Phys Original Article PURPOSE: The objective of the study is to use multiple tube phantoms to generate correction factor at different spatial locations for each breast coil cuff to correct the native T(10) value in the corresponding spatial location of the breast lesion. The corrected T(10) value was used to compute K(trans) and analyze its diagnostic accuracy in the classification of target condition, i.e., breast tumors into malignant and benign. MATERIALS AND METHODS: Both in vitro phantom study (external reference) and patient’s studies were acquired on simultaneous positron emission tomography/magnetic resonance imaging (PET/MRI) Biograph molecular magnetic resonance (mMR) system using 4 channel mMR breast coil. The spatial correction factors derived using multiple tube phantom were used for a retrospective analysis of dynamic contrast-enhanced (DCE) MRI data of 39 patients with a mean age of 50 years (31–77 years) having 51 enhancing breast lesions. RESULTS: Corrected and non-corrected receiver operating characteristic (ROC) curve analysis revealed a mean K(trans) value of 0.64 min(−1) and 0.60 min(−1), respectively. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and overall accuracy for non-corrected data were 86.21%, 81.82%, 86.20%, 81.81%, and 84.31%, respectively, and for corrected data were 93.10%, 86.36%, 90%, 90.47%, and 90.20% respectively. The area under curve (AUC) of corrected data was improved to 0.959 (95% confidence interval [CI] 0.862–0.994) from 0.824 (95% CI 0.694–0.918) of non-corrected data, and for NPV, it was improved to 90.47% from 81.81%, respectively. CONCLUSION: T(10) values were normalized using multiple tube phantom which was used for computation of K(trans). We found significant improvement in the diagnostic accuracy of corrected K(trans) values that results in better characterization of breast lesions. Wolters Kluwer - Medknow 2023 2023-04-18 /pmc/articles/PMC10277302/ /pubmed/37342602 http://dx.doi.org/10.4103/jmp.jmp_90_22 Text en Copyright: © 2023 Journal of Medical Physics https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Negi, Pradeep Singh Mehta, Shashi Bhushan Jena, Amarnath Rana, Prerana K(trans) Calculation Using Reference Method Corrected Native T(10) for Breast Cancer Diagnosis |
title | K(trans) Calculation Using Reference Method Corrected Native T(10) for Breast Cancer Diagnosis |
title_full | K(trans) Calculation Using Reference Method Corrected Native T(10) for Breast Cancer Diagnosis |
title_fullStr | K(trans) Calculation Using Reference Method Corrected Native T(10) for Breast Cancer Diagnosis |
title_full_unstemmed | K(trans) Calculation Using Reference Method Corrected Native T(10) for Breast Cancer Diagnosis |
title_short | K(trans) Calculation Using Reference Method Corrected Native T(10) for Breast Cancer Diagnosis |
title_sort | k(trans) calculation using reference method corrected native t(10) for breast cancer diagnosis |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10277302/ https://www.ncbi.nlm.nih.gov/pubmed/37342602 http://dx.doi.org/10.4103/jmp.jmp_90_22 |
work_keys_str_mv | AT negipradeepsingh ktranscalculationusingreferencemethodcorrectednativet10forbreastcancerdiagnosis AT mehtashashibhushan ktranscalculationusingreferencemethodcorrectednativet10forbreastcancerdiagnosis AT jenaamarnath ktranscalculationusingreferencemethodcorrectednativet10forbreastcancerdiagnosis AT ranaprerana ktranscalculationusingreferencemethodcorrectednativet10forbreastcancerdiagnosis |