Cargando…

Rotational Set Up Uncertainly in Non-6D Couch and its Effects in Clinical Target Volume- Planning Target Volume Margin Calculation for Different Sites

PURPOSE: The purpose of this study was to estimate and incorporate rotational error to translational error for clinical target volume (CTV) to planning target volume (PTV) margin calculations for non-6D couch. MATERIALS AND METHODS: The study involved cone-beam computed tomography (CBCT) images of t...

Descripción completa

Detalles Bibliográficos
Autores principales: Robert, Ngangom, Sehgal, Tinish, Singh, Ranjit, Oinam, Arun, Trivedi, Gaurav, Singh, Budhi, Bahl, Amit, Madan, Renu, Rai, Bhavana
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10277305/
https://www.ncbi.nlm.nih.gov/pubmed/37342596
http://dx.doi.org/10.4103/jmp.jmp_78_22
_version_ 1785060251669626880
author Robert, Ngangom
Sehgal, Tinish
Singh, Ranjit
Oinam, Arun
Trivedi, Gaurav
Singh, Budhi
Bahl, Amit
Madan, Renu
Rai, Bhavana
author_facet Robert, Ngangom
Sehgal, Tinish
Singh, Ranjit
Oinam, Arun
Trivedi, Gaurav
Singh, Budhi
Bahl, Amit
Madan, Renu
Rai, Bhavana
author_sort Robert, Ngangom
collection PubMed
description PURPOSE: The purpose of this study was to estimate and incorporate rotational error to translational error for clinical target volume (CTV) to planning target volume (PTV) margin calculations for non-6D couch. MATERIALS AND METHODS: The study involved cone-beam computed tomography (CBCT) images of the patients who already had treatment in Varian Trilogy Clinac. The different sites studied were brain (70 patients, 406 CBCT images), head and neck (72 patients, 356 CBCT images), pelvis (83 patients, 606 CBCT images), and breast (45 patients, 163 CBCT images). Rotational and translational patient shifts were measured with the help of Varian eclipse offline review. The rotational shift introduces translational shift as it resolved along craniocaudal and mediolateral directions. Both rotational and translational error follow normal distribution and their respective errors were used to calculate CTV-PTV margin using van Herk model. RESULTS: Rotational effect on CTV-PTV margin contribution increases with increase in size of CTV. It also increases with increase in distance between center of mass of CTV and isocenter. These margins were more pronounce in single isocenter supraclavicular fossa-Tangential Breast plans. CONCLUSIONS: There is always rotational error in all sites and it causes shift and rotation of the target. Rotational contribution to the CTV-PTV margin depends upon geometric center of CTV and isocenter distance and also on size of CTV. CTV-PTV margins should incorporate rotational error along with transitional error.
format Online
Article
Text
id pubmed-10277305
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-102773052023-06-20 Rotational Set Up Uncertainly in Non-6D Couch and its Effects in Clinical Target Volume- Planning Target Volume Margin Calculation for Different Sites Robert, Ngangom Sehgal, Tinish Singh, Ranjit Oinam, Arun Trivedi, Gaurav Singh, Budhi Bahl, Amit Madan, Renu Rai, Bhavana J Med Phys Original Article PURPOSE: The purpose of this study was to estimate and incorporate rotational error to translational error for clinical target volume (CTV) to planning target volume (PTV) margin calculations for non-6D couch. MATERIALS AND METHODS: The study involved cone-beam computed tomography (CBCT) images of the patients who already had treatment in Varian Trilogy Clinac. The different sites studied were brain (70 patients, 406 CBCT images), head and neck (72 patients, 356 CBCT images), pelvis (83 patients, 606 CBCT images), and breast (45 patients, 163 CBCT images). Rotational and translational patient shifts were measured with the help of Varian eclipse offline review. The rotational shift introduces translational shift as it resolved along craniocaudal and mediolateral directions. Both rotational and translational error follow normal distribution and their respective errors were used to calculate CTV-PTV margin using van Herk model. RESULTS: Rotational effect on CTV-PTV margin contribution increases with increase in size of CTV. It also increases with increase in distance between center of mass of CTV and isocenter. These margins were more pronounce in single isocenter supraclavicular fossa-Tangential Breast plans. CONCLUSIONS: There is always rotational error in all sites and it causes shift and rotation of the target. Rotational contribution to the CTV-PTV margin depends upon geometric center of CTV and isocenter distance and also on size of CTV. CTV-PTV margins should incorporate rotational error along with transitional error. Wolters Kluwer - Medknow 2023 2023-04-18 /pmc/articles/PMC10277305/ /pubmed/37342596 http://dx.doi.org/10.4103/jmp.jmp_78_22 Text en Copyright: © 2023 Journal of Medical Physics https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Robert, Ngangom
Sehgal, Tinish
Singh, Ranjit
Oinam, Arun
Trivedi, Gaurav
Singh, Budhi
Bahl, Amit
Madan, Renu
Rai, Bhavana
Rotational Set Up Uncertainly in Non-6D Couch and its Effects in Clinical Target Volume- Planning Target Volume Margin Calculation for Different Sites
title Rotational Set Up Uncertainly in Non-6D Couch and its Effects in Clinical Target Volume- Planning Target Volume Margin Calculation for Different Sites
title_full Rotational Set Up Uncertainly in Non-6D Couch and its Effects in Clinical Target Volume- Planning Target Volume Margin Calculation for Different Sites
title_fullStr Rotational Set Up Uncertainly in Non-6D Couch and its Effects in Clinical Target Volume- Planning Target Volume Margin Calculation for Different Sites
title_full_unstemmed Rotational Set Up Uncertainly in Non-6D Couch and its Effects in Clinical Target Volume- Planning Target Volume Margin Calculation for Different Sites
title_short Rotational Set Up Uncertainly in Non-6D Couch and its Effects in Clinical Target Volume- Planning Target Volume Margin Calculation for Different Sites
title_sort rotational set up uncertainly in non-6d couch and its effects in clinical target volume- planning target volume margin calculation for different sites
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10277305/
https://www.ncbi.nlm.nih.gov/pubmed/37342596
http://dx.doi.org/10.4103/jmp.jmp_78_22
work_keys_str_mv AT robertngangom rotationalsetupuncertainlyinnon6dcouchanditseffectsinclinicaltargetvolumeplanningtargetvolumemargincalculationfordifferentsites
AT sehgaltinish rotationalsetupuncertainlyinnon6dcouchanditseffectsinclinicaltargetvolumeplanningtargetvolumemargincalculationfordifferentsites
AT singhranjit rotationalsetupuncertainlyinnon6dcouchanditseffectsinclinicaltargetvolumeplanningtargetvolumemargincalculationfordifferentsites
AT oinamarun rotationalsetupuncertainlyinnon6dcouchanditseffectsinclinicaltargetvolumeplanningtargetvolumemargincalculationfordifferentsites
AT trivedigaurav rotationalsetupuncertainlyinnon6dcouchanditseffectsinclinicaltargetvolumeplanningtargetvolumemargincalculationfordifferentsites
AT singhbudhi rotationalsetupuncertainlyinnon6dcouchanditseffectsinclinicaltargetvolumeplanningtargetvolumemargincalculationfordifferentsites
AT bahlamit rotationalsetupuncertainlyinnon6dcouchanditseffectsinclinicaltargetvolumeplanningtargetvolumemargincalculationfordifferentsites
AT madanrenu rotationalsetupuncertainlyinnon6dcouchanditseffectsinclinicaltargetvolumeplanningtargetvolumemargincalculationfordifferentsites
AT raibhavana rotationalsetupuncertainlyinnon6dcouchanditseffectsinclinicaltargetvolumeplanningtargetvolumemargincalculationfordifferentsites