Cargando…
A Bioinspired Fluid-Filled Soft Linear Actuator
In bioinspired soft robotics, very few studies have focused on fluidic transmissions and there is an urgent need for translating fluidic concepts into realizable fluidic components to be applied in different fields. Nature has often offered an inspiring reference to design new efficient devices. Ins...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Mary Ann Liebert, Inc., publishers
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10278000/ https://www.ncbi.nlm.nih.gov/pubmed/36318817 http://dx.doi.org/10.1089/soro.2021.0091 |
_version_ | 1785060399440199680 |
---|---|
author | Filogna, Silvia Paternò, Linda Vecchi, Fabrizio Musco, Luigi Iacovacci, Veronica Menciassi, Arianna |
author_facet | Filogna, Silvia Paternò, Linda Vecchi, Fabrizio Musco, Luigi Iacovacci, Veronica Menciassi, Arianna |
author_sort | Filogna, Silvia |
collection | PubMed |
description | In bioinspired soft robotics, very few studies have focused on fluidic transmissions and there is an urgent need for translating fluidic concepts into realizable fluidic components to be applied in different fields. Nature has often offered an inspiring reference to design new efficient devices. Inspired by the working principle of a marine worm, the sipunculid species Phascolosoma stephensoni (Sipunculidae, Annelida), a soft linear fluidic actuator is here presented. The natural hydrostatic skeleton combined with muscle activity enables these organisms to protrude a part of their body to explore the surrounding. Looking at the hydrostatic skeleton and protrusion mechanism of sipunculids, our solution is based on a twofold fluidic component, exploiting the advantages of both pneumatic and hydraulic actuations and providing a novel fluidic transmission mechanism. The inflation of a soft pneumatic chamber is associated with the stretch of an inner hydraulic chamber due to the incompressibility of the liquid. Actuator stretch and forces have been characterized to determine system performance. In addition, an analytical model has been derived to relate the stretch ability to the inlet pressure. Three different sizes of prototypes were tested to evaluate the suitability of the proposed design for miniaturization. The proposed actuator features a strain equal to 40–50% of its initial length—depending on size—and output forces up to 18 N in the largest prototypes. The proposed bioinspired actuator expands the design of fluidic actuators and can pave the way for new approaches in soft robotics with potential application in the medical field. |
format | Online Article Text |
id | pubmed-10278000 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Mary Ann Liebert, Inc., publishers |
record_format | MEDLINE/PubMed |
spelling | pubmed-102780002023-06-20 A Bioinspired Fluid-Filled Soft Linear Actuator Filogna, Silvia Paternò, Linda Vecchi, Fabrizio Musco, Luigi Iacovacci, Veronica Menciassi, Arianna Soft Robot Original Articles In bioinspired soft robotics, very few studies have focused on fluidic transmissions and there is an urgent need for translating fluidic concepts into realizable fluidic components to be applied in different fields. Nature has often offered an inspiring reference to design new efficient devices. Inspired by the working principle of a marine worm, the sipunculid species Phascolosoma stephensoni (Sipunculidae, Annelida), a soft linear fluidic actuator is here presented. The natural hydrostatic skeleton combined with muscle activity enables these organisms to protrude a part of their body to explore the surrounding. Looking at the hydrostatic skeleton and protrusion mechanism of sipunculids, our solution is based on a twofold fluidic component, exploiting the advantages of both pneumatic and hydraulic actuations and providing a novel fluidic transmission mechanism. The inflation of a soft pneumatic chamber is associated with the stretch of an inner hydraulic chamber due to the incompressibility of the liquid. Actuator stretch and forces have been characterized to determine system performance. In addition, an analytical model has been derived to relate the stretch ability to the inlet pressure. Three different sizes of prototypes were tested to evaluate the suitability of the proposed design for miniaturization. The proposed actuator features a strain equal to 40–50% of its initial length—depending on size—and output forces up to 18 N in the largest prototypes. The proposed bioinspired actuator expands the design of fluidic actuators and can pave the way for new approaches in soft robotics with potential application in the medical field. Mary Ann Liebert, Inc., publishers 2023-06-01 2023-06-08 /pmc/articles/PMC10278000/ /pubmed/36318817 http://dx.doi.org/10.1089/soro.2021.0091 Text en © Silvia Filogna et al., 2023; Published by Mary Ann Liebert, Inc. https://creativecommons.org/licenses/by/4.0/This Open Access article is distributed under the terms of the Creative Commons License [CC-BY] (http://creativecommons.org/licenses/by/4.0 (https://creativecommons.org/licenses/by/4.0/) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Articles Filogna, Silvia Paternò, Linda Vecchi, Fabrizio Musco, Luigi Iacovacci, Veronica Menciassi, Arianna A Bioinspired Fluid-Filled Soft Linear Actuator |
title | A Bioinspired Fluid-Filled Soft Linear Actuator |
title_full | A Bioinspired Fluid-Filled Soft Linear Actuator |
title_fullStr | A Bioinspired Fluid-Filled Soft Linear Actuator |
title_full_unstemmed | A Bioinspired Fluid-Filled Soft Linear Actuator |
title_short | A Bioinspired Fluid-Filled Soft Linear Actuator |
title_sort | bioinspired fluid-filled soft linear actuator |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10278000/ https://www.ncbi.nlm.nih.gov/pubmed/36318817 http://dx.doi.org/10.1089/soro.2021.0091 |
work_keys_str_mv | AT filognasilvia abioinspiredfluidfilledsoftlinearactuator AT paternolinda abioinspiredfluidfilledsoftlinearactuator AT vecchifabrizio abioinspiredfluidfilledsoftlinearactuator AT muscoluigi abioinspiredfluidfilledsoftlinearactuator AT iacovacciveronica abioinspiredfluidfilledsoftlinearactuator AT menciassiarianna abioinspiredfluidfilledsoftlinearactuator AT filognasilvia bioinspiredfluidfilledsoftlinearactuator AT paternolinda bioinspiredfluidfilledsoftlinearactuator AT vecchifabrizio bioinspiredfluidfilledsoftlinearactuator AT muscoluigi bioinspiredfluidfilledsoftlinearactuator AT iacovacciveronica bioinspiredfluidfilledsoftlinearactuator AT menciassiarianna bioinspiredfluidfilledsoftlinearactuator |