Cargando…

Magnetic resonance myocardial T1ρ mapping: Technical overview, challenges, emerging developments, and clinical applications

The potential of cardiac magnetic resonance to improve cardiovascular care and patient management is considerable. Myocardial T1-rho (T1ρ) mapping, in particular, has emerged as a promising biomarker for quantifying myocardial injuries without exogenous contrast agents. Its potential as a contrast-a...

Descripción completa

Detalles Bibliográficos
Autores principales: Bustin, Aurelien, Witschey, Walter R. T., van Heeswijk, Ruud B., Cochet, Hubert, Stuber, Matthias
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10278347/
https://www.ncbi.nlm.nih.gov/pubmed/37331930
http://dx.doi.org/10.1186/s12968-023-00940-1
_version_ 1785060465920966656
author Bustin, Aurelien
Witschey, Walter R. T.
van Heeswijk, Ruud B.
Cochet, Hubert
Stuber, Matthias
author_facet Bustin, Aurelien
Witschey, Walter R. T.
van Heeswijk, Ruud B.
Cochet, Hubert
Stuber, Matthias
author_sort Bustin, Aurelien
collection PubMed
description The potential of cardiac magnetic resonance to improve cardiovascular care and patient management is considerable. Myocardial T1-rho (T1ρ) mapping, in particular, has emerged as a promising biomarker for quantifying myocardial injuries without exogenous contrast agents. Its potential as a contrast-agent-free (“needle-free”) and cost-effective diagnostic marker promises high impact both in terms of clinical outcomes and patient comfort. However, myocardial T1ρ mapping is still at a nascent stage of development and the evidence supporting its diagnostic performance and clinical effectiveness is scant, though likely to change with technological improvements. The present review aims at providing a primer on the essentials of myocardial T1ρ mapping, and to describe the current range of clinical applications of the technique to detect and quantify myocardial injuries. We also delineate the important limitations and challenges for clinical deployment, including the urgent need for standardization, the evaluation of bias, and the critical importance of clinical testing. We conclude by outlining technical developments to be expected in the future. If needle-free myocardial T1ρ mapping is shown to improve patient diagnosis and prognosis, and can be effectively integrated in cardiovascular practice, it will fulfill its potential as an essential component of a cardiac magnetic resonance examination.
format Online
Article
Text
id pubmed-10278347
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-102783472023-06-20 Magnetic resonance myocardial T1ρ mapping: Technical overview, challenges, emerging developments, and clinical applications Bustin, Aurelien Witschey, Walter R. T. van Heeswijk, Ruud B. Cochet, Hubert Stuber, Matthias J Cardiovasc Magn Reson Review The potential of cardiac magnetic resonance to improve cardiovascular care and patient management is considerable. Myocardial T1-rho (T1ρ) mapping, in particular, has emerged as a promising biomarker for quantifying myocardial injuries without exogenous contrast agents. Its potential as a contrast-agent-free (“needle-free”) and cost-effective diagnostic marker promises high impact both in terms of clinical outcomes and patient comfort. However, myocardial T1ρ mapping is still at a nascent stage of development and the evidence supporting its diagnostic performance and clinical effectiveness is scant, though likely to change with technological improvements. The present review aims at providing a primer on the essentials of myocardial T1ρ mapping, and to describe the current range of clinical applications of the technique to detect and quantify myocardial injuries. We also delineate the important limitations and challenges for clinical deployment, including the urgent need for standardization, the evaluation of bias, and the critical importance of clinical testing. We conclude by outlining technical developments to be expected in the future. If needle-free myocardial T1ρ mapping is shown to improve patient diagnosis and prognosis, and can be effectively integrated in cardiovascular practice, it will fulfill its potential as an essential component of a cardiac magnetic resonance examination. BioMed Central 2023-06-19 /pmc/articles/PMC10278347/ /pubmed/37331930 http://dx.doi.org/10.1186/s12968-023-00940-1 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Review
Bustin, Aurelien
Witschey, Walter R. T.
van Heeswijk, Ruud B.
Cochet, Hubert
Stuber, Matthias
Magnetic resonance myocardial T1ρ mapping: Technical overview, challenges, emerging developments, and clinical applications
title Magnetic resonance myocardial T1ρ mapping: Technical overview, challenges, emerging developments, and clinical applications
title_full Magnetic resonance myocardial T1ρ mapping: Technical overview, challenges, emerging developments, and clinical applications
title_fullStr Magnetic resonance myocardial T1ρ mapping: Technical overview, challenges, emerging developments, and clinical applications
title_full_unstemmed Magnetic resonance myocardial T1ρ mapping: Technical overview, challenges, emerging developments, and clinical applications
title_short Magnetic resonance myocardial T1ρ mapping: Technical overview, challenges, emerging developments, and clinical applications
title_sort magnetic resonance myocardial t1ρ mapping: technical overview, challenges, emerging developments, and clinical applications
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10278347/
https://www.ncbi.nlm.nih.gov/pubmed/37331930
http://dx.doi.org/10.1186/s12968-023-00940-1
work_keys_str_mv AT bustinaurelien magneticresonancemyocardialt1rmappingtechnicaloverviewchallengesemergingdevelopmentsandclinicalapplications
AT witscheywalterrt magneticresonancemyocardialt1rmappingtechnicaloverviewchallengesemergingdevelopmentsandclinicalapplications
AT vanheeswijkruudb magneticresonancemyocardialt1rmappingtechnicaloverviewchallengesemergingdevelopmentsandclinicalapplications
AT cochethubert magneticresonancemyocardialt1rmappingtechnicaloverviewchallengesemergingdevelopmentsandclinicalapplications
AT stubermatthias magneticresonancemyocardialt1rmappingtechnicaloverviewchallengesemergingdevelopmentsandclinicalapplications