Cargando…

Diagnostic value of ACR TI-RADS combined with three-dimensional shear wave elastography in ACR TI-RADS 4 and 5 thyroid nodules

BACKGROUND: Three-dimensional shear wave elastography (3D-SWE) is a promising method in distinguishing benign and malignant thyroid nodules. By combining with conventional method, it may further improve the diagnostic value. The study aimed to assess the diagnostic value of American College of Radio...

Descripción completa

Detalles Bibliográficos
Autores principales: Hao, Lijun, Liu, Peiqing, Ding, Changwei, Li, Jing, Zhang, Yingchun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10278707/
https://www.ncbi.nlm.nih.gov/pubmed/37075764
http://dx.doi.org/10.1097/CM9.0000000000002655
_version_ 1785060533717696512
author Hao, Lijun
Liu, Peiqing
Ding, Changwei
Li, Jing
Zhang, Yingchun
author_facet Hao, Lijun
Liu, Peiqing
Ding, Changwei
Li, Jing
Zhang, Yingchun
author_sort Hao, Lijun
collection PubMed
description BACKGROUND: Three-dimensional shear wave elastography (3D-SWE) is a promising method in distinguishing benign and malignant thyroid nodules. By combining with conventional method, it may further improve the diagnostic value. The study aimed to assess the diagnostic value of American College of Radiology (ACR) thyroid imaging reporting and data system (TI-RADS) combined with 3D-SWE in ACR TI-RADS 4 and 5 thyroid nodules. METHODS: All nodules were examined by conventional ultrasonography, ACR TI-RADS classification, and 3D-SWE examination. Conventional ultrasonography was used to observe the location, size, shape, margin, echogenicity, taller-than-wide sign, microcalcification, and blood flow of thyroid nodules, and then ACR TI-RADS classification was performed. The Young's modulus values (3D-C-Emax, 3D-C-Emean, and elastography standard deviation [3D-C-Esd]) were measured on the reconstructed coronal plane images. According to the receiver operating characteristic (ROC) curve, the best diagnostic efficiency among 3D-C-Emax, 3D-C-Emean, and 3D-C-Esd was selected and the cut-off threshold was calculated. According to the surgical pathology, they were divided into benign group and malignant group. And appropriate statistical methods such as t-test and Mann–Whitney U test were used to compare the difference between the two groups. On this basis, 3D-SWE combined with conventional ACR TI-RADS was reclassified as combined ACR TI-RADS to determine benign or malignant thyroid nodules. RESULTS: Of the 112 thyroid nodules, 62 were malignant and 50 were benign. The optimal cut-off value of three-dimensional maximum Young's modulus in coronal plane (3D-C-Emax) was 51.5 kPa and the area under the curve (AUC) was 0.798. The AUC, sensitivity, specificity, and accuracy of conventional ACR TI-RADS were 0.828, 83.9%, 66.0%, and 75.9%, respectively. The AUC, sensitivity, specificity, and accuracy of combined ACR TI-RADS were 0.845, 90.3%, 66.0%, and 79.5%, respectively. The difference between the two AUC values was statistically significant. CONCLUSIONS: Combined ACR TI-RADS has higher diagnostic efficiency than conventional ACR TI-RADS. The sensitivity and accuracy of combined ACR TI-RADS showed significant improvements. It can be used as an effective method in the diagnosis of thyroid nodules.
format Online
Article
Text
id pubmed-10278707
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-102787072023-06-20 Diagnostic value of ACR TI-RADS combined with three-dimensional shear wave elastography in ACR TI-RADS 4 and 5 thyroid nodules Hao, Lijun Liu, Peiqing Ding, Changwei Li, Jing Zhang, Yingchun Chin Med J (Engl) Original Article BACKGROUND: Three-dimensional shear wave elastography (3D-SWE) is a promising method in distinguishing benign and malignant thyroid nodules. By combining with conventional method, it may further improve the diagnostic value. The study aimed to assess the diagnostic value of American College of Radiology (ACR) thyroid imaging reporting and data system (TI-RADS) combined with 3D-SWE in ACR TI-RADS 4 and 5 thyroid nodules. METHODS: All nodules were examined by conventional ultrasonography, ACR TI-RADS classification, and 3D-SWE examination. Conventional ultrasonography was used to observe the location, size, shape, margin, echogenicity, taller-than-wide sign, microcalcification, and blood flow of thyroid nodules, and then ACR TI-RADS classification was performed. The Young's modulus values (3D-C-Emax, 3D-C-Emean, and elastography standard deviation [3D-C-Esd]) were measured on the reconstructed coronal plane images. According to the receiver operating characteristic (ROC) curve, the best diagnostic efficiency among 3D-C-Emax, 3D-C-Emean, and 3D-C-Esd was selected and the cut-off threshold was calculated. According to the surgical pathology, they were divided into benign group and malignant group. And appropriate statistical methods such as t-test and Mann–Whitney U test were used to compare the difference between the two groups. On this basis, 3D-SWE combined with conventional ACR TI-RADS was reclassified as combined ACR TI-RADS to determine benign or malignant thyroid nodules. RESULTS: Of the 112 thyroid nodules, 62 were malignant and 50 were benign. The optimal cut-off value of three-dimensional maximum Young's modulus in coronal plane (3D-C-Emax) was 51.5 kPa and the area under the curve (AUC) was 0.798. The AUC, sensitivity, specificity, and accuracy of conventional ACR TI-RADS were 0.828, 83.9%, 66.0%, and 75.9%, respectively. The AUC, sensitivity, specificity, and accuracy of combined ACR TI-RADS were 0.845, 90.3%, 66.0%, and 79.5%, respectively. The difference between the two AUC values was statistically significant. CONCLUSIONS: Combined ACR TI-RADS has higher diagnostic efficiency than conventional ACR TI-RADS. The sensitivity and accuracy of combined ACR TI-RADS showed significant improvements. It can be used as an effective method in the diagnosis of thyroid nodules. Lippincott Williams & Wilkins 2023-04-19 2023-05-20 /pmc/articles/PMC10278707/ /pubmed/37075764 http://dx.doi.org/10.1097/CM9.0000000000002655 Text en Copyright © 2023 The Chinese Medical Association, produced by Wolters Kluwer, Inc. under the CC-BY-NC-ND license. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/)
spellingShingle Original Article
Hao, Lijun
Liu, Peiqing
Ding, Changwei
Li, Jing
Zhang, Yingchun
Diagnostic value of ACR TI-RADS combined with three-dimensional shear wave elastography in ACR TI-RADS 4 and 5 thyroid nodules
title Diagnostic value of ACR TI-RADS combined with three-dimensional shear wave elastography in ACR TI-RADS 4 and 5 thyroid nodules
title_full Diagnostic value of ACR TI-RADS combined with three-dimensional shear wave elastography in ACR TI-RADS 4 and 5 thyroid nodules
title_fullStr Diagnostic value of ACR TI-RADS combined with three-dimensional shear wave elastography in ACR TI-RADS 4 and 5 thyroid nodules
title_full_unstemmed Diagnostic value of ACR TI-RADS combined with three-dimensional shear wave elastography in ACR TI-RADS 4 and 5 thyroid nodules
title_short Diagnostic value of ACR TI-RADS combined with three-dimensional shear wave elastography in ACR TI-RADS 4 and 5 thyroid nodules
title_sort diagnostic value of acr ti-rads combined with three-dimensional shear wave elastography in acr ti-rads 4 and 5 thyroid nodules
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10278707/
https://www.ncbi.nlm.nih.gov/pubmed/37075764
http://dx.doi.org/10.1097/CM9.0000000000002655
work_keys_str_mv AT haolijun diagnosticvalueofacrtiradscombinedwiththreedimensionalshearwaveelastographyinacrtirads4and5thyroidnodules
AT liupeiqing diagnosticvalueofacrtiradscombinedwiththreedimensionalshearwaveelastographyinacrtirads4and5thyroidnodules
AT dingchangwei diagnosticvalueofacrtiradscombinedwiththreedimensionalshearwaveelastographyinacrtirads4and5thyroidnodules
AT lijing diagnosticvalueofacrtiradscombinedwiththreedimensionalshearwaveelastographyinacrtirads4and5thyroidnodules
AT zhangyingchun diagnosticvalueofacrtiradscombinedwiththreedimensionalshearwaveelastographyinacrtirads4and5thyroidnodules