Cargando…

Safety and Accuracy of Professional Continuous Glucose Monitoring in Patients Undergoing Allogeneic Hematopoietic Stem Cell Transplantation

Hyperglycemia in the early days following allogeneic hematopoietic stem cell transplantation (allo-HSCT) is a well-known risk factor for acute graft-versus-host disease (GVHD) and non-relapse mortality. The FreeStyle Libre Pro, a factory calibrated continuous glucose monitoring (CGM) device, has bee...

Descripción completa

Detalles Bibliográficos
Autores principales: Nagao, Shigeki, Yakushijin, Kimikazu, Higashime, Ako, Kawaguchi, Koji, Watanabe, Marika, Sakai, Rina, Ichikawa, Hiroya, Mizutani, Yu, Goto, Hideaki, Kakiuchi, Seiji, Kurata, Keiji, Kitao, Akihito, Miyata, Yoshiharu, Imamura, Yoshinori, Hirota, Yushi, Takahashi, Michiko, Kawamoto, Shinichiro, Yamamoto, Katsuya, Matsuoka, Hiroshi, Minami, Hironobu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Asia-Pacific Blood and Marrow Transplantation Group 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10279490/
https://www.ncbi.nlm.nih.gov/pubmed/37342353
http://dx.doi.org/10.31547/bct-2022-024
_version_ 1785060602683588608
author Nagao, Shigeki
Yakushijin, Kimikazu
Higashime, Ako
Kawaguchi, Koji
Watanabe, Marika
Sakai, Rina
Ichikawa, Hiroya
Mizutani, Yu
Goto, Hideaki
Kakiuchi, Seiji
Kurata, Keiji
Kitao, Akihito
Miyata, Yoshiharu
Imamura, Yoshinori
Hirota, Yushi
Takahashi, Michiko
Kawamoto, Shinichiro
Yamamoto, Katsuya
Matsuoka, Hiroshi
Minami, Hironobu
author_facet Nagao, Shigeki
Yakushijin, Kimikazu
Higashime, Ako
Kawaguchi, Koji
Watanabe, Marika
Sakai, Rina
Ichikawa, Hiroya
Mizutani, Yu
Goto, Hideaki
Kakiuchi, Seiji
Kurata, Keiji
Kitao, Akihito
Miyata, Yoshiharu
Imamura, Yoshinori
Hirota, Yushi
Takahashi, Michiko
Kawamoto, Shinichiro
Yamamoto, Katsuya
Matsuoka, Hiroshi
Minami, Hironobu
author_sort Nagao, Shigeki
collection PubMed
description Hyperglycemia in the early days following allogeneic hematopoietic stem cell transplantation (allo-HSCT) is a well-known risk factor for acute graft-versus-host disease (GVHD) and non-relapse mortality. The FreeStyle Libre Pro, a factory calibrated continuous glucose monitoring (CGM) device, has been used for the retrospective analysis of glucose testing in patients with diabetes. We assessed the safety and accuracy of the device in patients undergoing allo-HSCT. We recruited eight patients who underwent allo-HSCT between August 2017 and March 2020. They wore the FreeStyle Libre Pro on the day before or on the day of transplantation until 28 days after transplantation. Adverse events, especially bleeding and infection, were monitored to assess safety, and blood glucose levels were measured and compared with the device values. None of the eight participants experienced bleeding that was difficult to stop from the sensor site or local infection that required antimicrobial administration. The device value was well correlated with blood glucose (correlation coefficient r=0.795, P<0.01); however, the overall mean absolute relative difference was 32.1%±16.0%. Our study demonstrated the safety of FreeStyle Libre Pro in allo-HSCT patients. However, the sensor results tended to be lower than the blood glucose levels.
format Online
Article
Text
id pubmed-10279490
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Asia-Pacific Blood and Marrow Transplantation Group
record_format MEDLINE/PubMed
spelling pubmed-102794902023-06-20 Safety and Accuracy of Professional Continuous Glucose Monitoring in Patients Undergoing Allogeneic Hematopoietic Stem Cell Transplantation Nagao, Shigeki Yakushijin, Kimikazu Higashime, Ako Kawaguchi, Koji Watanabe, Marika Sakai, Rina Ichikawa, Hiroya Mizutani, Yu Goto, Hideaki Kakiuchi, Seiji Kurata, Keiji Kitao, Akihito Miyata, Yoshiharu Imamura, Yoshinori Hirota, Yushi Takahashi, Michiko Kawamoto, Shinichiro Yamamoto, Katsuya Matsuoka, Hiroshi Minami, Hironobu Blood Cell Ther Original Article Hyperglycemia in the early days following allogeneic hematopoietic stem cell transplantation (allo-HSCT) is a well-known risk factor for acute graft-versus-host disease (GVHD) and non-relapse mortality. The FreeStyle Libre Pro, a factory calibrated continuous glucose monitoring (CGM) device, has been used for the retrospective analysis of glucose testing in patients with diabetes. We assessed the safety and accuracy of the device in patients undergoing allo-HSCT. We recruited eight patients who underwent allo-HSCT between August 2017 and March 2020. They wore the FreeStyle Libre Pro on the day before or on the day of transplantation until 28 days after transplantation. Adverse events, especially bleeding and infection, were monitored to assess safety, and blood glucose levels were measured and compared with the device values. None of the eight participants experienced bleeding that was difficult to stop from the sensor site or local infection that required antimicrobial administration. The device value was well correlated with blood glucose (correlation coefficient r=0.795, P<0.01); however, the overall mean absolute relative difference was 32.1%±16.0%. Our study demonstrated the safety of FreeStyle Libre Pro in allo-HSCT patients. However, the sensor results tended to be lower than the blood glucose levels. Asia-Pacific Blood and Marrow Transplantation Group 2023-03-24 /pmc/articles/PMC10279490/ /pubmed/37342353 http://dx.doi.org/10.31547/bct-2022-024 Text en Copyright Ⓒ2023 Asia-Pacific Blood and Marrow Transplantation Group (APBMT). https://creativecommons.org/licenses/by-nc/4.0/This is an open access article distributed under CC BY-NC license (https://creativecommons.org/licenses/by-nc/4.0/).
spellingShingle Original Article
Nagao, Shigeki
Yakushijin, Kimikazu
Higashime, Ako
Kawaguchi, Koji
Watanabe, Marika
Sakai, Rina
Ichikawa, Hiroya
Mizutani, Yu
Goto, Hideaki
Kakiuchi, Seiji
Kurata, Keiji
Kitao, Akihito
Miyata, Yoshiharu
Imamura, Yoshinori
Hirota, Yushi
Takahashi, Michiko
Kawamoto, Shinichiro
Yamamoto, Katsuya
Matsuoka, Hiroshi
Minami, Hironobu
Safety and Accuracy of Professional Continuous Glucose Monitoring in Patients Undergoing Allogeneic Hematopoietic Stem Cell Transplantation
title Safety and Accuracy of Professional Continuous Glucose Monitoring in Patients Undergoing Allogeneic Hematopoietic Stem Cell Transplantation
title_full Safety and Accuracy of Professional Continuous Glucose Monitoring in Patients Undergoing Allogeneic Hematopoietic Stem Cell Transplantation
title_fullStr Safety and Accuracy of Professional Continuous Glucose Monitoring in Patients Undergoing Allogeneic Hematopoietic Stem Cell Transplantation
title_full_unstemmed Safety and Accuracy of Professional Continuous Glucose Monitoring in Patients Undergoing Allogeneic Hematopoietic Stem Cell Transplantation
title_short Safety and Accuracy of Professional Continuous Glucose Monitoring in Patients Undergoing Allogeneic Hematopoietic Stem Cell Transplantation
title_sort safety and accuracy of professional continuous glucose monitoring in patients undergoing allogeneic hematopoietic stem cell transplantation
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10279490/
https://www.ncbi.nlm.nih.gov/pubmed/37342353
http://dx.doi.org/10.31547/bct-2022-024
work_keys_str_mv AT nagaoshigeki safetyandaccuracyofprofessionalcontinuousglucosemonitoringinpatientsundergoingallogeneichematopoieticstemcelltransplantation
AT yakushijinkimikazu safetyandaccuracyofprofessionalcontinuousglucosemonitoringinpatientsundergoingallogeneichematopoieticstemcelltransplantation
AT higashimeako safetyandaccuracyofprofessionalcontinuousglucosemonitoringinpatientsundergoingallogeneichematopoieticstemcelltransplantation
AT kawaguchikoji safetyandaccuracyofprofessionalcontinuousglucosemonitoringinpatientsundergoingallogeneichematopoieticstemcelltransplantation
AT watanabemarika safetyandaccuracyofprofessionalcontinuousglucosemonitoringinpatientsundergoingallogeneichematopoieticstemcelltransplantation
AT sakairina safetyandaccuracyofprofessionalcontinuousglucosemonitoringinpatientsundergoingallogeneichematopoieticstemcelltransplantation
AT ichikawahiroya safetyandaccuracyofprofessionalcontinuousglucosemonitoringinpatientsundergoingallogeneichematopoieticstemcelltransplantation
AT mizutaniyu safetyandaccuracyofprofessionalcontinuousglucosemonitoringinpatientsundergoingallogeneichematopoieticstemcelltransplantation
AT gotohideaki safetyandaccuracyofprofessionalcontinuousglucosemonitoringinpatientsundergoingallogeneichematopoieticstemcelltransplantation
AT kakiuchiseiji safetyandaccuracyofprofessionalcontinuousglucosemonitoringinpatientsundergoingallogeneichematopoieticstemcelltransplantation
AT kuratakeiji safetyandaccuracyofprofessionalcontinuousglucosemonitoringinpatientsundergoingallogeneichematopoieticstemcelltransplantation
AT kitaoakihito safetyandaccuracyofprofessionalcontinuousglucosemonitoringinpatientsundergoingallogeneichematopoieticstemcelltransplantation
AT miyatayoshiharu safetyandaccuracyofprofessionalcontinuousglucosemonitoringinpatientsundergoingallogeneichematopoieticstemcelltransplantation
AT imamurayoshinori safetyandaccuracyofprofessionalcontinuousglucosemonitoringinpatientsundergoingallogeneichematopoieticstemcelltransplantation
AT hirotayushi safetyandaccuracyofprofessionalcontinuousglucosemonitoringinpatientsundergoingallogeneichematopoieticstemcelltransplantation
AT takahashimichiko safetyandaccuracyofprofessionalcontinuousglucosemonitoringinpatientsundergoingallogeneichematopoieticstemcelltransplantation
AT kawamotoshinichiro safetyandaccuracyofprofessionalcontinuousglucosemonitoringinpatientsundergoingallogeneichematopoieticstemcelltransplantation
AT yamamotokatsuya safetyandaccuracyofprofessionalcontinuousglucosemonitoringinpatientsundergoingallogeneichematopoieticstemcelltransplantation
AT matsuokahiroshi safetyandaccuracyofprofessionalcontinuousglucosemonitoringinpatientsundergoingallogeneichematopoieticstemcelltransplantation
AT minamihironobu safetyandaccuracyofprofessionalcontinuousglucosemonitoringinpatientsundergoingallogeneichematopoieticstemcelltransplantation