Cargando…

Predictive Value of Electromechanical Window for Risk of Fatal Ventricular Arrhythmia

BACKGROUND: As an indicator of electro-mechanical coupling, electromechanical window (EMW) can be used to predict fatal ventricular arrhythmias. We investigated the additive effect of EMW on the prediction of fatal ventricular arrhythmias in high-risk patients. METHODS: We included patients who had...

Descripción completa

Detalles Bibliográficos
Autores principales: Rhee, Tae-Min, Ahn, Hyo-Jeong, Kim, Sunhwa, Lee, So-Ryoung, Choi, Eue-Keun, Oh, Seil
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Academy of Medical Sciences 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10279514/
https://www.ncbi.nlm.nih.gov/pubmed/37337809
http://dx.doi.org/10.3346/jkms.2023.38.e186
Descripción
Sumario:BACKGROUND: As an indicator of electro-mechanical coupling, electromechanical window (EMW) can be used to predict fatal ventricular arrhythmias. We investigated the additive effect of EMW on the prediction of fatal ventricular arrhythmias in high-risk patients. METHODS: We included patients who had implantable cardioverter-defibrillator (ICD) implanted for primary or secondary prevention. The event group was defined as those who received an appropriate ICD therapy. We acquired echocardiograms at ICD implantation and follow-up. The EMW was calculated as the difference between the interval from QRS onset to aortic valve closure and QT interval from the electrocardiogram embedded in the continuous wave doppler image. We evaluated the predictive value of EMW for predicting fatal ventricular arrhythmia. RESULTS: Of 245 patients (67.2 ± 12.8 years, 63.7% men), the event group was 20.0%. EMW at baseline (EMW-Baseline) and follow-up (EMW-FU) was significantly different between event and control groups. After adjustment, both EMW-Baseline (odds ratio [OR](adjust) 1.02 [1.01–1.03], P = 0.004) and EMW-FU (OR(adjust) 1.06 [1.04–1.07], P < 0.001) remained as significant predictors for fatal arrhythmic events. Adding EMW-Baseline significantly improved the discriminating ability of the multivariable model including clinical variables (area under the curve [AUC] 0.77 [0.70–0.84] vs. AUC 0.72 [0.64–0.80], P = 0.004), while a univariable model using EMW-FU alone showed the best performance among models (AUC 0.87 [0.81–0.94], P = 0.060 against model with clinical variables; P = 0.030 against model with clinical variables and EMW-Baseline). CONCLUSION: The EMW could effectively predict severe ventricular arrhythmia in ICD implanted patients. This finding supports the importance of incorporating the electro-mechanical coupling index into the clinical practice for predicting future fatal arrhythmia events.