Cargando…

Assessing the impact and resource implications of contrast-enhanced ultrasound on workflow of patients with incidental focal liver lesions on the UK national health service

BACKGROUND: Focal liver lesions (FLL) are abnormal growths that require timely identification. Contrast-enhanced ultrasound (CEUS) is a cost-effective imaging modality for characterising FLL with similar sensitivity to computed tomography (CT) and magnetic resonance imaging (MRI). Despite being reco...

Descripción completa

Detalles Bibliográficos
Autores principales: O’Brien, Megan, Oliver, Louisa, Proctor, Nick, Siakantari, Maro, Cantin, Peter, Griffin, Colin P., Stenberg, Ben
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10280539/
https://www.ncbi.nlm.nih.gov/pubmed/37346968
http://dx.doi.org/10.1177/20584601231183131
_version_ 1785060817393156096
author O’Brien, Megan
Oliver, Louisa
Proctor, Nick
Siakantari, Maro
Cantin, Peter
Griffin, Colin P.
Stenberg, Ben
author_facet O’Brien, Megan
Oliver, Louisa
Proctor, Nick
Siakantari, Maro
Cantin, Peter
Griffin, Colin P.
Stenberg, Ben
author_sort O’Brien, Megan
collection PubMed
description BACKGROUND: Focal liver lesions (FLL) are abnormal growths that require timely identification. Contrast-enhanced ultrasound (CEUS) is a cost-effective imaging modality for characterising FLL with similar sensitivity to computed tomography (CT) and magnetic resonance imaging (MRI). Despite being recommended by NICE, its adoption within the national health service (NHS) is limited due to low clinical demand, limited referral, and lack of knowledge. PURPOSE: To evaluate the impact of CEUS on patients with incidental FLL and assess the resource implications of introducing CEUS as a diagnostic service within the NHS. MATERIAL AND METHODS: A patient flow review and cost-minimisation analysis were conducted. This involved a targeted literature review, NHS Trust stakeholder consultations, and development of a Microsoft Excel cost-minimisation model to explore potential value of CEUS use versus CT and MRI by episode. A scenario analysis of the base-case explored increasing CEUS use to 50% and 90%. A sensitivity analysis was performed to assess how changes in assumptions impacted the model and the resulting cost estimates. RESULTS: The model, comparing a world with and without CEUS, showed that current use (base-case: 5%) resulted in cost savings of £224,790/year. The sensitivity analysis indicated that regardless of changes to the assumptions, CEUS still resulted in cost savings to the NHS. By increasing CEUS use to 50% and 90%, cost savings of up to £2,247,894/year and £4,046,208/year could be achieved, respectively. CONCLUSION: By standardising CEUS use for characterising FLL, substantial cost savings could be realised, whilst reducing wait times and expanding diagnostic capacity, thus preserving limited CT and MRI capacity for high-priority cases.
format Online
Article
Text
id pubmed-10280539
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-102805392023-06-21 Assessing the impact and resource implications of contrast-enhanced ultrasound on workflow of patients with incidental focal liver lesions on the UK national health service O’Brien, Megan Oliver, Louisa Proctor, Nick Siakantari, Maro Cantin, Peter Griffin, Colin P. Stenberg, Ben Acta Radiol Open Original Article BACKGROUND: Focal liver lesions (FLL) are abnormal growths that require timely identification. Contrast-enhanced ultrasound (CEUS) is a cost-effective imaging modality for characterising FLL with similar sensitivity to computed tomography (CT) and magnetic resonance imaging (MRI). Despite being recommended by NICE, its adoption within the national health service (NHS) is limited due to low clinical demand, limited referral, and lack of knowledge. PURPOSE: To evaluate the impact of CEUS on patients with incidental FLL and assess the resource implications of introducing CEUS as a diagnostic service within the NHS. MATERIAL AND METHODS: A patient flow review and cost-minimisation analysis were conducted. This involved a targeted literature review, NHS Trust stakeholder consultations, and development of a Microsoft Excel cost-minimisation model to explore potential value of CEUS use versus CT and MRI by episode. A scenario analysis of the base-case explored increasing CEUS use to 50% and 90%. A sensitivity analysis was performed to assess how changes in assumptions impacted the model and the resulting cost estimates. RESULTS: The model, comparing a world with and without CEUS, showed that current use (base-case: 5%) resulted in cost savings of £224,790/year. The sensitivity analysis indicated that regardless of changes to the assumptions, CEUS still resulted in cost savings to the NHS. By increasing CEUS use to 50% and 90%, cost savings of up to £2,247,894/year and £4,046,208/year could be achieved, respectively. CONCLUSION: By standardising CEUS use for characterising FLL, substantial cost savings could be realised, whilst reducing wait times and expanding diagnostic capacity, thus preserving limited CT and MRI capacity for high-priority cases. SAGE Publications 2023-06-13 /pmc/articles/PMC10280539/ /pubmed/37346968 http://dx.doi.org/10.1177/20584601231183131 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Article
O’Brien, Megan
Oliver, Louisa
Proctor, Nick
Siakantari, Maro
Cantin, Peter
Griffin, Colin P.
Stenberg, Ben
Assessing the impact and resource implications of contrast-enhanced ultrasound on workflow of patients with incidental focal liver lesions on the UK national health service
title Assessing the impact and resource implications of contrast-enhanced ultrasound on workflow of patients with incidental focal liver lesions on the UK national health service
title_full Assessing the impact and resource implications of contrast-enhanced ultrasound on workflow of patients with incidental focal liver lesions on the UK national health service
title_fullStr Assessing the impact and resource implications of contrast-enhanced ultrasound on workflow of patients with incidental focal liver lesions on the UK national health service
title_full_unstemmed Assessing the impact and resource implications of contrast-enhanced ultrasound on workflow of patients with incidental focal liver lesions on the UK national health service
title_short Assessing the impact and resource implications of contrast-enhanced ultrasound on workflow of patients with incidental focal liver lesions on the UK national health service
title_sort assessing the impact and resource implications of contrast-enhanced ultrasound on workflow of patients with incidental focal liver lesions on the uk national health service
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10280539/
https://www.ncbi.nlm.nih.gov/pubmed/37346968
http://dx.doi.org/10.1177/20584601231183131
work_keys_str_mv AT obrienmegan assessingtheimpactandresourceimplicationsofcontrastenhancedultrasoundonworkflowofpatientswithincidentalfocalliverlesionsontheuknationalhealthservice
AT oliverlouisa assessingtheimpactandresourceimplicationsofcontrastenhancedultrasoundonworkflowofpatientswithincidentalfocalliverlesionsontheuknationalhealthservice
AT proctornick assessingtheimpactandresourceimplicationsofcontrastenhancedultrasoundonworkflowofpatientswithincidentalfocalliverlesionsontheuknationalhealthservice
AT siakantarimaro assessingtheimpactandresourceimplicationsofcontrastenhancedultrasoundonworkflowofpatientswithincidentalfocalliverlesionsontheuknationalhealthservice
AT cantinpeter assessingtheimpactandresourceimplicationsofcontrastenhancedultrasoundonworkflowofpatientswithincidentalfocalliverlesionsontheuknationalhealthservice
AT griffincolinp assessingtheimpactandresourceimplicationsofcontrastenhancedultrasoundonworkflowofpatientswithincidentalfocalliverlesionsontheuknationalhealthservice
AT stenbergben assessingtheimpactandresourceimplicationsofcontrastenhancedultrasoundonworkflowofpatientswithincidentalfocalliverlesionsontheuknationalhealthservice