Cargando…

The effect of preparation design on the fracture resistance and adaptation of the CEREC ceramic endocrowns

OBJECTIVE: The purpose of this experimental in vitro study was to assess the effect of having one or two intact axial walls on the improvement of the fracture resistance, and marginal and internal adaptation of computer‐aided design/computer‐aided manufacturer fabricated ceramic endocrowns. MATERIAL...

Descripción completa

Detalles Bibliográficos
Autores principales: Jalali, Samar, Jalali, Hamid, Kharazi Fard, Mohammad Javad, Abdolrahmani, Ali, Alikhasi, Marzieh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10280620/
https://www.ncbi.nlm.nih.gov/pubmed/36949716
http://dx.doi.org/10.1002/cre2.726
_version_ 1785060837008867328
author Jalali, Samar
Jalali, Hamid
Kharazi Fard, Mohammad Javad
Abdolrahmani, Ali
Alikhasi, Marzieh
author_facet Jalali, Samar
Jalali, Hamid
Kharazi Fard, Mohammad Javad
Abdolrahmani, Ali
Alikhasi, Marzieh
author_sort Jalali, Samar
collection PubMed
description OBJECTIVE: The purpose of this experimental in vitro study was to assess the effect of having one or two intact axial walls on the improvement of the fracture resistance, and marginal and internal adaptation of computer‐aided design/computer‐aided manufacturer fabricated ceramic endocrowns. MATERIALS AND METHODS: Thirty‐six endodontically treated mandibular molars were divided into three groups (n = 12). Group A, represented teeth that all of their axial walls were reduced till they all had 3 mm height. In group B, the buccal wall had 5 mm height and the others were reduced to 3 mm. Specimens of the group C had 5‐mm‐height buccal and one 5 mm‐height proximal wall, with all other walls of 3 mm height. All teeth were scanned using intraoral scanner, and endocrowns were milled from zirconia lithium silicate ceramics blocks. The marginal and internal discrepancy of restorations were evaluated with the replica technique. Fracture resistance was also measured after cementation and modes of failure were observed. One‐way analysis of variance and Tukey HSD multiple comparisons were used to analyze the data (α = .5). RESULTS: Significant differences were observed within the groups in terms of the axial discrepancy (p = .022); group A had significantly higher amounts of axial discrepancy compared to group B (p = .001) and group C (p = .003). Preservation of the intact axial walls did not result in a statistically significant decrease in marginal (p = .21) and pulpal (p = .31) discrepancy values. Also, concerning the fracture resistance no significant difference was observed among the groups (p = .51). CONCLUSION: Preservation of at least one of the axial walls could reduce the amount of the axial discrepancy and, therefore, improves the adaptation of the restoration. However, based on this study, it did not improve fracture resistance.
format Online
Article
Text
id pubmed-10280620
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-102806202023-06-21 The effect of preparation design on the fracture resistance and adaptation of the CEREC ceramic endocrowns Jalali, Samar Jalali, Hamid Kharazi Fard, Mohammad Javad Abdolrahmani, Ali Alikhasi, Marzieh Clin Exp Dent Res Original Articles OBJECTIVE: The purpose of this experimental in vitro study was to assess the effect of having one or two intact axial walls on the improvement of the fracture resistance, and marginal and internal adaptation of computer‐aided design/computer‐aided manufacturer fabricated ceramic endocrowns. MATERIALS AND METHODS: Thirty‐six endodontically treated mandibular molars were divided into three groups (n = 12). Group A, represented teeth that all of their axial walls were reduced till they all had 3 mm height. In group B, the buccal wall had 5 mm height and the others were reduced to 3 mm. Specimens of the group C had 5‐mm‐height buccal and one 5 mm‐height proximal wall, with all other walls of 3 mm height. All teeth were scanned using intraoral scanner, and endocrowns were milled from zirconia lithium silicate ceramics blocks. The marginal and internal discrepancy of restorations were evaluated with the replica technique. Fracture resistance was also measured after cementation and modes of failure were observed. One‐way analysis of variance and Tukey HSD multiple comparisons were used to analyze the data (α = .5). RESULTS: Significant differences were observed within the groups in terms of the axial discrepancy (p = .022); group A had significantly higher amounts of axial discrepancy compared to group B (p = .001) and group C (p = .003). Preservation of the intact axial walls did not result in a statistically significant decrease in marginal (p = .21) and pulpal (p = .31) discrepancy values. Also, concerning the fracture resistance no significant difference was observed among the groups (p = .51). CONCLUSION: Preservation of at least one of the axial walls could reduce the amount of the axial discrepancy and, therefore, improves the adaptation of the restoration. However, based on this study, it did not improve fracture resistance. John Wiley and Sons Inc. 2023-03-22 /pmc/articles/PMC10280620/ /pubmed/36949716 http://dx.doi.org/10.1002/cre2.726 Text en © 2023 The Authors. Clinical and Experimental Dental Research published by John Wiley & Sons Ltd. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Articles
Jalali, Samar
Jalali, Hamid
Kharazi Fard, Mohammad Javad
Abdolrahmani, Ali
Alikhasi, Marzieh
The effect of preparation design on the fracture resistance and adaptation of the CEREC ceramic endocrowns
title The effect of preparation design on the fracture resistance and adaptation of the CEREC ceramic endocrowns
title_full The effect of preparation design on the fracture resistance and adaptation of the CEREC ceramic endocrowns
title_fullStr The effect of preparation design on the fracture resistance and adaptation of the CEREC ceramic endocrowns
title_full_unstemmed The effect of preparation design on the fracture resistance and adaptation of the CEREC ceramic endocrowns
title_short The effect of preparation design on the fracture resistance and adaptation of the CEREC ceramic endocrowns
title_sort effect of preparation design on the fracture resistance and adaptation of the cerec ceramic endocrowns
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10280620/
https://www.ncbi.nlm.nih.gov/pubmed/36949716
http://dx.doi.org/10.1002/cre2.726
work_keys_str_mv AT jalalisamar theeffectofpreparationdesignonthefractureresistanceandadaptationofthecerecceramicendocrowns
AT jalalihamid theeffectofpreparationdesignonthefractureresistanceandadaptationofthecerecceramicendocrowns
AT kharazifardmohammadjavad theeffectofpreparationdesignonthefractureresistanceandadaptationofthecerecceramicendocrowns
AT abdolrahmaniali theeffectofpreparationdesignonthefractureresistanceandadaptationofthecerecceramicendocrowns
AT alikhasimarzieh theeffectofpreparationdesignonthefractureresistanceandadaptationofthecerecceramicendocrowns
AT jalalisamar effectofpreparationdesignonthefractureresistanceandadaptationofthecerecceramicendocrowns
AT jalalihamid effectofpreparationdesignonthefractureresistanceandadaptationofthecerecceramicendocrowns
AT kharazifardmohammadjavad effectofpreparationdesignonthefractureresistanceandadaptationofthecerecceramicendocrowns
AT abdolrahmaniali effectofpreparationdesignonthefractureresistanceandadaptationofthecerecceramicendocrowns
AT alikhasimarzieh effectofpreparationdesignonthefractureresistanceandadaptationofthecerecceramicendocrowns