Cargando…
High-resolution ultrasound tendon-to-bone distances in partial and complete finger flexor A2 pulley ruptures simulated in human cadaver dissection: toward understanding imaging of partial pulley ruptures
Introduction: The A2 pulley tear is the most common injury in rock climbing. Whereas complete A2 pulley ruptures have been extensively researched, studies focused on partial A2 pulley ruptures are lacking. A2 pulleys rupture distally to proximally. High-resolution ultrasound imaging is considered th...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10282126/ https://www.ncbi.nlm.nih.gov/pubmed/37351474 http://dx.doi.org/10.3389/fbioe.2023.1123857 |
_version_ | 1785061128885239808 |
---|---|
author | Iruretagoiena, Xeber Schöffl, Volker Balius, Ramón Blasi, Marc Dávila, Fernando Sala, Xavier Sancho, Igor De La Fuente, Javier |
author_facet | Iruretagoiena, Xeber Schöffl, Volker Balius, Ramón Blasi, Marc Dávila, Fernando Sala, Xavier Sancho, Igor De La Fuente, Javier |
author_sort | Iruretagoiena, Xeber |
collection | PubMed |
description | Introduction: The A2 pulley tear is the most common injury in rock climbing. Whereas complete A2 pulley ruptures have been extensively researched, studies focused on partial A2 pulley ruptures are lacking. A2 pulleys rupture distally to proximally. High-resolution ultrasound imaging is considered the gold-standard tool for diagnosis and the most relevant ultrasound measurement is the tendon-to-bone distance (TBD), which increases when the pulley ruptures. The purpose of this study was to establish tendon-to-bone distance values for different sizes of partial A2 pulley ruptures and compare these values with those of complete ruptures. Material and methods: The sample consisted of 30 in vitro fingers randomly assigned to 5 groups: G1, no simulated tear (control); G2, simulated 5 mm tear (low-grade partial rupture); G3, simulated 10 mm tear (medium-grade partial rupture); G4, simulated 15 mm tear (high-grade partial rupture); and G5, simulated 20 mm or equivalent tear (complete rupture). A highly experienced sonographer blinded to the randomization process and dissections examined all fingers. Results: The tendon-to-bone distance measurements (medians and interquartile ranges) were as follows: G1, 0.95 mm (0.77–1.33); G2, 2.11 mm (1.78–2.33); G3, 2.28 mm (1.95–2.42); G4, 3.06 mm (2.79–3.28); and G5, 3.66 mm (3.55–4.76). Significant differences were found between non-torn pulleys and simulated partial and complete pulley ruptures. Discussion: In contrast, and inconsistent with other findings, no significant differences were found among the different partial rupture groups. In conclusion, the longer the partial pulley rupture, the higher the tendon-to-bone distance value. The literature is inconsistent regarding the tendon-to-bone distance threshold to diagnose a partial A2 pulley rupture. The minimum tendon-to-bone distance value for a partial rupture was 1.6 mm, and tendon-to-bone distance values above 3 mm suggest a high-grade partial pulley rupture (15 mm incision) or a complete pulley rupture. |
format | Online Article Text |
id | pubmed-10282126 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-102821262023-06-22 High-resolution ultrasound tendon-to-bone distances in partial and complete finger flexor A2 pulley ruptures simulated in human cadaver dissection: toward understanding imaging of partial pulley ruptures Iruretagoiena, Xeber Schöffl, Volker Balius, Ramón Blasi, Marc Dávila, Fernando Sala, Xavier Sancho, Igor De La Fuente, Javier Front Bioeng Biotechnol Bioengineering and Biotechnology Introduction: The A2 pulley tear is the most common injury in rock climbing. Whereas complete A2 pulley ruptures have been extensively researched, studies focused on partial A2 pulley ruptures are lacking. A2 pulleys rupture distally to proximally. High-resolution ultrasound imaging is considered the gold-standard tool for diagnosis and the most relevant ultrasound measurement is the tendon-to-bone distance (TBD), which increases when the pulley ruptures. The purpose of this study was to establish tendon-to-bone distance values for different sizes of partial A2 pulley ruptures and compare these values with those of complete ruptures. Material and methods: The sample consisted of 30 in vitro fingers randomly assigned to 5 groups: G1, no simulated tear (control); G2, simulated 5 mm tear (low-grade partial rupture); G3, simulated 10 mm tear (medium-grade partial rupture); G4, simulated 15 mm tear (high-grade partial rupture); and G5, simulated 20 mm or equivalent tear (complete rupture). A highly experienced sonographer blinded to the randomization process and dissections examined all fingers. Results: The tendon-to-bone distance measurements (medians and interquartile ranges) were as follows: G1, 0.95 mm (0.77–1.33); G2, 2.11 mm (1.78–2.33); G3, 2.28 mm (1.95–2.42); G4, 3.06 mm (2.79–3.28); and G5, 3.66 mm (3.55–4.76). Significant differences were found between non-torn pulleys and simulated partial and complete pulley ruptures. Discussion: In contrast, and inconsistent with other findings, no significant differences were found among the different partial rupture groups. In conclusion, the longer the partial pulley rupture, the higher the tendon-to-bone distance value. The literature is inconsistent regarding the tendon-to-bone distance threshold to diagnose a partial A2 pulley rupture. The minimum tendon-to-bone distance value for a partial rupture was 1.6 mm, and tendon-to-bone distance values above 3 mm suggest a high-grade partial pulley rupture (15 mm incision) or a complete pulley rupture. Frontiers Media S.A. 2023-06-07 /pmc/articles/PMC10282126/ /pubmed/37351474 http://dx.doi.org/10.3389/fbioe.2023.1123857 Text en Copyright © 2023 Iruretagoiena, Schöffl, Balius, Blasi, Dávila, Sala, Sancho and De La Fuente. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Bioengineering and Biotechnology Iruretagoiena, Xeber Schöffl, Volker Balius, Ramón Blasi, Marc Dávila, Fernando Sala, Xavier Sancho, Igor De La Fuente, Javier High-resolution ultrasound tendon-to-bone distances in partial and complete finger flexor A2 pulley ruptures simulated in human cadaver dissection: toward understanding imaging of partial pulley ruptures |
title | High-resolution ultrasound tendon-to-bone distances in partial and complete finger flexor A2 pulley ruptures simulated in human cadaver dissection: toward understanding imaging of partial pulley ruptures |
title_full | High-resolution ultrasound tendon-to-bone distances in partial and complete finger flexor A2 pulley ruptures simulated in human cadaver dissection: toward understanding imaging of partial pulley ruptures |
title_fullStr | High-resolution ultrasound tendon-to-bone distances in partial and complete finger flexor A2 pulley ruptures simulated in human cadaver dissection: toward understanding imaging of partial pulley ruptures |
title_full_unstemmed | High-resolution ultrasound tendon-to-bone distances in partial and complete finger flexor A2 pulley ruptures simulated in human cadaver dissection: toward understanding imaging of partial pulley ruptures |
title_short | High-resolution ultrasound tendon-to-bone distances in partial and complete finger flexor A2 pulley ruptures simulated in human cadaver dissection: toward understanding imaging of partial pulley ruptures |
title_sort | high-resolution ultrasound tendon-to-bone distances in partial and complete finger flexor a2 pulley ruptures simulated in human cadaver dissection: toward understanding imaging of partial pulley ruptures |
topic | Bioengineering and Biotechnology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10282126/ https://www.ncbi.nlm.nih.gov/pubmed/37351474 http://dx.doi.org/10.3389/fbioe.2023.1123857 |
work_keys_str_mv | AT iruretagoienaxeber highresolutionultrasoundtendontobonedistancesinpartialandcompletefingerflexora2pulleyrupturessimulatedinhumancadaverdissectiontowardunderstandingimagingofpartialpulleyruptures AT schofflvolker highresolutionultrasoundtendontobonedistancesinpartialandcompletefingerflexora2pulleyrupturessimulatedinhumancadaverdissectiontowardunderstandingimagingofpartialpulleyruptures AT baliusramon highresolutionultrasoundtendontobonedistancesinpartialandcompletefingerflexora2pulleyrupturessimulatedinhumancadaverdissectiontowardunderstandingimagingofpartialpulleyruptures AT blasimarc highresolutionultrasoundtendontobonedistancesinpartialandcompletefingerflexora2pulleyrupturessimulatedinhumancadaverdissectiontowardunderstandingimagingofpartialpulleyruptures AT davilafernando highresolutionultrasoundtendontobonedistancesinpartialandcompletefingerflexora2pulleyrupturessimulatedinhumancadaverdissectiontowardunderstandingimagingofpartialpulleyruptures AT salaxavier highresolutionultrasoundtendontobonedistancesinpartialandcompletefingerflexora2pulleyrupturessimulatedinhumancadaverdissectiontowardunderstandingimagingofpartialpulleyruptures AT sanchoigor highresolutionultrasoundtendontobonedistancesinpartialandcompletefingerflexora2pulleyrupturessimulatedinhumancadaverdissectiontowardunderstandingimagingofpartialpulleyruptures AT delafuentejavier highresolutionultrasoundtendontobonedistancesinpartialandcompletefingerflexora2pulleyrupturessimulatedinhumancadaverdissectiontowardunderstandingimagingofpartialpulleyruptures |