Cargando…
Accuracy of bony resection under computer-assisted navigation for bone sarcomas around the knee
BACKGROUND: Computer-assisted navigation has made bone sarcoma resections more precise. However, further clinical studies involving accuracy analyses under navigation are still warranted. METHODS: A retrospective study for analysis of computer-assisted navigation accuracy was carried out. Between Se...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10283339/ https://www.ncbi.nlm.nih.gov/pubmed/37344874 http://dx.doi.org/10.1186/s12957-023-03071-0 |
_version_ | 1785061291898961920 |
---|---|
author | Deng, Zhiping Zhang, Qing Hao, Lin Ding, Yi Niu, Xiaohui Liu, Weifeng |
author_facet | Deng, Zhiping Zhang, Qing Hao, Lin Ding, Yi Niu, Xiaohui Liu, Weifeng |
author_sort | Deng, Zhiping |
collection | PubMed |
description | BACKGROUND: Computer-assisted navigation has made bone sarcoma resections more precise. However, further clinical studies involving accuracy analyses under navigation are still warranted. METHODS: A retrospective study for analysis of computer-assisted navigation accuracy was carried out. Between September 2008 and November 2017, 39 cases of bone sarcomas around the knee joint were resected under computer-assisted navigation. The control group comprised 117 cases of bone sarcomas around the knee treated by limb salvage surgery wherein bony cutting was achieved freehand. The length difference (LD) was defined as the specimen length minus the planned resection length. The LDs were detected in both groups and compared. The margin accuracy (MA) was defined as the achieved margin minus the desired margin at the bone cutting site and was detected in the navigation group. RESULTS: The LDs between the postoperative specimen length and the preoperative planned length were compared. In the navigation group, the LD was 0.5 ± 2.5 mm (range, − 5 to 5 mm), while in the freehand group, the LD was 3.4 ± 9.6 mm (range, − 20 to 29 mm), with a significant difference (P < 0.01). In the absolute value analysis, the LD absolute value was 2.0 ± 1.6 mm in the navigation group and 8.3 ± 6.0 mm in the freehand group, with a significant difference (P < 0.01). In the navigation group, the MA was 0.3 ± 1.5 mm (range, − 3 to 3 mm) and the MA absolute value was 1.1 ± 1.0 mm. CONCLUSIONS: Better accuracy can be achieved when computer-assisted navigation is conducted for bone sarcoma resection around the knee. LEVEL OF EVIDENCE: IV. |
format | Online Article Text |
id | pubmed-10283339 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-102833392023-06-22 Accuracy of bony resection under computer-assisted navigation for bone sarcomas around the knee Deng, Zhiping Zhang, Qing Hao, Lin Ding, Yi Niu, Xiaohui Liu, Weifeng World J Surg Oncol Research BACKGROUND: Computer-assisted navigation has made bone sarcoma resections more precise. However, further clinical studies involving accuracy analyses under navigation are still warranted. METHODS: A retrospective study for analysis of computer-assisted navigation accuracy was carried out. Between September 2008 and November 2017, 39 cases of bone sarcomas around the knee joint were resected under computer-assisted navigation. The control group comprised 117 cases of bone sarcomas around the knee treated by limb salvage surgery wherein bony cutting was achieved freehand. The length difference (LD) was defined as the specimen length minus the planned resection length. The LDs were detected in both groups and compared. The margin accuracy (MA) was defined as the achieved margin minus the desired margin at the bone cutting site and was detected in the navigation group. RESULTS: The LDs between the postoperative specimen length and the preoperative planned length were compared. In the navigation group, the LD was 0.5 ± 2.5 mm (range, − 5 to 5 mm), while in the freehand group, the LD was 3.4 ± 9.6 mm (range, − 20 to 29 mm), with a significant difference (P < 0.01). In the absolute value analysis, the LD absolute value was 2.0 ± 1.6 mm in the navigation group and 8.3 ± 6.0 mm in the freehand group, with a significant difference (P < 0.01). In the navigation group, the MA was 0.3 ± 1.5 mm (range, − 3 to 3 mm) and the MA absolute value was 1.1 ± 1.0 mm. CONCLUSIONS: Better accuracy can be achieved when computer-assisted navigation is conducted for bone sarcoma resection around the knee. LEVEL OF EVIDENCE: IV. BioMed Central 2023-06-21 /pmc/articles/PMC10283339/ /pubmed/37344874 http://dx.doi.org/10.1186/s12957-023-03071-0 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Deng, Zhiping Zhang, Qing Hao, Lin Ding, Yi Niu, Xiaohui Liu, Weifeng Accuracy of bony resection under computer-assisted navigation for bone sarcomas around the knee |
title | Accuracy of bony resection under computer-assisted navigation for bone sarcomas around the knee |
title_full | Accuracy of bony resection under computer-assisted navigation for bone sarcomas around the knee |
title_fullStr | Accuracy of bony resection under computer-assisted navigation for bone sarcomas around the knee |
title_full_unstemmed | Accuracy of bony resection under computer-assisted navigation for bone sarcomas around the knee |
title_short | Accuracy of bony resection under computer-assisted navigation for bone sarcomas around the knee |
title_sort | accuracy of bony resection under computer-assisted navigation for bone sarcomas around the knee |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10283339/ https://www.ncbi.nlm.nih.gov/pubmed/37344874 http://dx.doi.org/10.1186/s12957-023-03071-0 |
work_keys_str_mv | AT dengzhiping accuracyofbonyresectionundercomputerassistednavigationforbonesarcomasaroundtheknee AT zhangqing accuracyofbonyresectionundercomputerassistednavigationforbonesarcomasaroundtheknee AT haolin accuracyofbonyresectionundercomputerassistednavigationforbonesarcomasaroundtheknee AT dingyi accuracyofbonyresectionundercomputerassistednavigationforbonesarcomasaroundtheknee AT niuxiaohui accuracyofbonyresectionundercomputerassistednavigationforbonesarcomasaroundtheknee AT liuweifeng accuracyofbonyresectionundercomputerassistednavigationforbonesarcomasaroundtheknee |