Cargando…
Comparision of Cardiac Output Measured by Transthoracic Echocardiography with Continuous Cardiac Output Measured by Pressure Recording Analytical Method
BACKGROUND: Low cardiac output is a common complication following cardiac surgery and it is associated with higher mortality in the pediatric population. A gold standard method for cardiac output (CO) monitoring in the pediatric population is lacking. The present study was conducted to validate card...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10284471/ https://www.ncbi.nlm.nih.gov/pubmed/37706379 http://dx.doi.org/10.4103/aca.aca_41_22 |
_version_ | 1785061409648803840 |
---|---|
author | Madhuri, M. Roja Singh, Naveen G. Nagaraja, P. S Pranathi, E Shankar, C. G Prabhu Satish, N Prabhakar, V Gupta, Apoorva |
author_facet | Madhuri, M. Roja Singh, Naveen G. Nagaraja, P. S Pranathi, E Shankar, C. G Prabhu Satish, N Prabhakar, V Gupta, Apoorva |
author_sort | Madhuri, M. Roja |
collection | PubMed |
description | BACKGROUND: Low cardiac output is a common complication following cardiac surgery and it is associated with higher mortality in the pediatric population. A gold standard method for cardiac output (CO) monitoring in the pediatric population is lacking. The present study was conducted to validate cardiac output and cardiac index measured by transthoracic echocardiography and Pressure recording analytical method, a continuous pulse contour method, MostCare (Up) in postoperative pediatric cardiac surgical patients. MATERIALS AND METHODS: This was a prospective observational clinical study conducted at a tertiary care hospital. A total of 23 pediatric patients weighed between 2 and 20 kg who had undergone elective cardiac surgery were included in the study. RESULTS: Spearman’s correlation coefficient of CO between transthoracic echocardiography (TTE) and Pressure Recording Analytical Method (PRAM) showed of positive correlation (r = 0.69, 95% Confidence interval 0.59-0.77, P < 0.0001) Linear regression equations for CO between TTE and PRAM were y = 0.55 + 0.88x (R(2) = 0.46, P < 0.0001). (y = PRAM, x = TTE), respectively. Bland- Altman plot for CO between TTE and PRAM showed a bias of -0.397 with limits of the agreement being -2.01 to 1.22. Polar plot analysis showed an angular bias of 6.55° with radial limits of the agreement being -21.46 to 34.58 for CO and angular bias of 6.22° with radial limits of the agreement being -22.4 to 34.84 for CI. CONCLUSION: PRAM has shown good trending ability for cardiac output. However, values measured by PRAM are not interchangeable with the values measured by transthoracic echocardiography. |
format | Online Article Text |
id | pubmed-10284471 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-102844712023-06-22 Comparision of Cardiac Output Measured by Transthoracic Echocardiography with Continuous Cardiac Output Measured by Pressure Recording Analytical Method Madhuri, M. Roja Singh, Naveen G. Nagaraja, P. S Pranathi, E Shankar, C. G Prabhu Satish, N Prabhakar, V Gupta, Apoorva Ann Card Anaesth Original Article BACKGROUND: Low cardiac output is a common complication following cardiac surgery and it is associated with higher mortality in the pediatric population. A gold standard method for cardiac output (CO) monitoring in the pediatric population is lacking. The present study was conducted to validate cardiac output and cardiac index measured by transthoracic echocardiography and Pressure recording analytical method, a continuous pulse contour method, MostCare (Up) in postoperative pediatric cardiac surgical patients. MATERIALS AND METHODS: This was a prospective observational clinical study conducted at a tertiary care hospital. A total of 23 pediatric patients weighed between 2 and 20 kg who had undergone elective cardiac surgery were included in the study. RESULTS: Spearman’s correlation coefficient of CO between transthoracic echocardiography (TTE) and Pressure Recording Analytical Method (PRAM) showed of positive correlation (r = 0.69, 95% Confidence interval 0.59-0.77, P < 0.0001) Linear regression equations for CO between TTE and PRAM were y = 0.55 + 0.88x (R(2) = 0.46, P < 0.0001). (y = PRAM, x = TTE), respectively. Bland- Altman plot for CO between TTE and PRAM showed a bias of -0.397 with limits of the agreement being -2.01 to 1.22. Polar plot analysis showed an angular bias of 6.55° with radial limits of the agreement being -21.46 to 34.58 for CO and angular bias of 6.22° with radial limits of the agreement being -22.4 to 34.84 for CI. CONCLUSION: PRAM has shown good trending ability for cardiac output. However, values measured by PRAM are not interchangeable with the values measured by transthoracic echocardiography. Wolters Kluwer - Medknow 2023 2023-04-03 /pmc/articles/PMC10284471/ /pubmed/37706379 http://dx.doi.org/10.4103/aca.aca_41_22 Text en Copyright: © 2023 Annals of Cardiac Anaesthesia https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Madhuri, M. Roja Singh, Naveen G. Nagaraja, P. S Pranathi, E Shankar, C. G Prabhu Satish, N Prabhakar, V Gupta, Apoorva Comparision of Cardiac Output Measured by Transthoracic Echocardiography with Continuous Cardiac Output Measured by Pressure Recording Analytical Method |
title | Comparision of Cardiac Output Measured by Transthoracic Echocardiography with Continuous Cardiac Output Measured by Pressure Recording Analytical Method |
title_full | Comparision of Cardiac Output Measured by Transthoracic Echocardiography with Continuous Cardiac Output Measured by Pressure Recording Analytical Method |
title_fullStr | Comparision of Cardiac Output Measured by Transthoracic Echocardiography with Continuous Cardiac Output Measured by Pressure Recording Analytical Method |
title_full_unstemmed | Comparision of Cardiac Output Measured by Transthoracic Echocardiography with Continuous Cardiac Output Measured by Pressure Recording Analytical Method |
title_short | Comparision of Cardiac Output Measured by Transthoracic Echocardiography with Continuous Cardiac Output Measured by Pressure Recording Analytical Method |
title_sort | comparision of cardiac output measured by transthoracic echocardiography with continuous cardiac output measured by pressure recording analytical method |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10284471/ https://www.ncbi.nlm.nih.gov/pubmed/37706379 http://dx.doi.org/10.4103/aca.aca_41_22 |
work_keys_str_mv | AT madhurimroja comparisionofcardiacoutputmeasuredbytransthoracicechocardiographywithcontinuouscardiacoutputmeasuredbypressurerecordinganalyticalmethod AT singhnaveeng comparisionofcardiacoutputmeasuredbytransthoracicechocardiographywithcontinuouscardiacoutputmeasuredbypressurerecordinganalyticalmethod AT nagarajaps comparisionofcardiacoutputmeasuredbytransthoracicechocardiographywithcontinuouscardiacoutputmeasuredbypressurerecordinganalyticalmethod AT pranathie comparisionofcardiacoutputmeasuredbytransthoracicechocardiographywithcontinuouscardiacoutputmeasuredbypressurerecordinganalyticalmethod AT shankarcgprabhu comparisionofcardiacoutputmeasuredbytransthoracicechocardiographywithcontinuouscardiacoutputmeasuredbypressurerecordinganalyticalmethod AT satishn comparisionofcardiacoutputmeasuredbytransthoracicechocardiographywithcontinuouscardiacoutputmeasuredbypressurerecordinganalyticalmethod AT prabhakarv comparisionofcardiacoutputmeasuredbytransthoracicechocardiographywithcontinuouscardiacoutputmeasuredbypressurerecordinganalyticalmethod AT guptaapoorva comparisionofcardiacoutputmeasuredbytransthoracicechocardiographywithcontinuouscardiacoutputmeasuredbypressurerecordinganalyticalmethod |