Transcatheter Mitral Valve Implantation: Implications of Interventional Technique and 3D Echocardiography for Complex Valve-in-Valve Paravalvular Leak

Transcatheter mitral valve replacement (TMVR) has emerged as a feasible alternative to surgical reoperation in failed bioprostheses and rings. Residual mitral regurgitation following TMVR can present as a valve-in-valve paravalvular leak (PVL) and is associated with increased morbidity and mortality...

Descripción completa

Detalles Bibliográficos
Autores principales: Sehgal, Sankalp, Subramanyam, Pritha, Ahluwalia, Monica, Rastogi, Ashish, Bergman, Geoffrey
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10284472/
https://www.ncbi.nlm.nih.gov/pubmed/37706394
http://dx.doi.org/10.4103/aca.aca_166_21
Descripción
Sumario:Transcatheter mitral valve replacement (TMVR) has emerged as a feasible alternative to surgical reoperation in failed bioprostheses and rings. Residual mitral regurgitation following TMVR can present as a valve-in-valve paravalvular leak (PVL) and is associated with increased morbidity and mortality. Current therapies for valve-in-valve PVL are limited. We present a case of a symptomatic patient with severe valve-in-valve PVL after TMVR for a previous surgical bioprosthesis leak, who then underwent a second TMVR as a valve-in-valve-in-valve implantation with a 29 mm Edwards SAPIEN 3 valve via transseptal approach using three-dimensional (3D) echocardiography. This unique case highlights the complexity of this clinical entity and recognizes 3D transesophageal echocardiography as a valuable tool to guide valve-in-valve PVL closures.