Cargando…
Conventional Prostheses versus Sutureless Perceval for Aortic Valve Replacement: A Meta-Analysis
Purpose: Perceval sutureless valves have gained popularity. Whether this implant performs superior to the traditional sutured prosthesis remains unclear. This meta-analysis compared the Perceval implants versus the sutured conventional valves for aortic valve replacement (AVR). Methods: This meta-an...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Editorial Committee of Annals of Thoracic and Cardiovascular Surgery
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10284666/ https://www.ncbi.nlm.nih.gov/pubmed/36517036 http://dx.doi.org/10.5761/atcs.ra.22-00125 |
_version_ | 1785061452171706368 |
---|---|
author | Colarossi, Giorgia Migliorini, Filippo Becker, Michael Arias, Jessica P Autschbach, Ruediger Moza, Ajay Aljalloud, Ali |
author_facet | Colarossi, Giorgia Migliorini, Filippo Becker, Michael Arias, Jessica P Autschbach, Ruediger Moza, Ajay Aljalloud, Ali |
author_sort | Colarossi, Giorgia |
collection | PubMed |
description | Purpose: Perceval sutureless valves have gained popularity. Whether this implant performs superior to the traditional sutured prosthesis remains unclear. This meta-analysis compared the Perceval implants versus the sutured conventional valves for aortic valve replacement (AVR). Methods: This meta-analysis was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. The following databases were accessed: PubMed, Google Scholar, Web of Science, Scopus, and EMBASE. All clinical investigations comparing Perceval versus the conventional prostheses for AVR were considered. Results: The Perceval group demonstrated higher rate of pacemaker implantation (P <0.00001). Aortic cross-clamp (ACC) time (P <0.00001) and cardiopulmonary bypass (CPB) time (P <0.00001) were shorter in the Perceval group. Similarity was found in mean and peak pressure gradient (P = 0.8 and P = 0.2, respectively), mean aortic valve area (P = 0.3), length of intensive care unit (P = 0.4) and hospital stay (P = 0.2), rate of revision (P = 0.11), hemorrhages (P = 0.05), paravalvular leak (P = 0.3), cerebrovascular complication (P = 0.7), and early mortality (P = 0.06). Conclusion: Given the shorter ACC time and CPB time, Perceval AVR can be an alternative in high-risk patients. The higher rate of pacemaker implantation following Perceval may limit its routine implantation. |
format | Online Article Text |
id | pubmed-10284666 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | The Editorial Committee of Annals of Thoracic and Cardiovascular Surgery |
record_format | MEDLINE/PubMed |
spelling | pubmed-102846662023-06-22 Conventional Prostheses versus Sutureless Perceval for Aortic Valve Replacement: A Meta-Analysis Colarossi, Giorgia Migliorini, Filippo Becker, Michael Arias, Jessica P Autschbach, Ruediger Moza, Ajay Aljalloud, Ali Ann Thorac Cardiovasc Surg Review Article Purpose: Perceval sutureless valves have gained popularity. Whether this implant performs superior to the traditional sutured prosthesis remains unclear. This meta-analysis compared the Perceval implants versus the sutured conventional valves for aortic valve replacement (AVR). Methods: This meta-analysis was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. The following databases were accessed: PubMed, Google Scholar, Web of Science, Scopus, and EMBASE. All clinical investigations comparing Perceval versus the conventional prostheses for AVR were considered. Results: The Perceval group demonstrated higher rate of pacemaker implantation (P <0.00001). Aortic cross-clamp (ACC) time (P <0.00001) and cardiopulmonary bypass (CPB) time (P <0.00001) were shorter in the Perceval group. Similarity was found in mean and peak pressure gradient (P = 0.8 and P = 0.2, respectively), mean aortic valve area (P = 0.3), length of intensive care unit (P = 0.4) and hospital stay (P = 0.2), rate of revision (P = 0.11), hemorrhages (P = 0.05), paravalvular leak (P = 0.3), cerebrovascular complication (P = 0.7), and early mortality (P = 0.06). Conclusion: Given the shorter ACC time and CPB time, Perceval AVR can be an alternative in high-risk patients. The higher rate of pacemaker implantation following Perceval may limit its routine implantation. The Editorial Committee of Annals of Thoracic and Cardiovascular Surgery 2022-12-15 2023 /pmc/articles/PMC10284666/ /pubmed/36517036 http://dx.doi.org/10.5761/atcs.ra.22-00125 Text en ©2023 Annals of Thoracic and Cardiovascular Surgery https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives International License (https://creativecommons.org/licenses/by-nc-nd/4.0/) |
spellingShingle | Review Article Colarossi, Giorgia Migliorini, Filippo Becker, Michael Arias, Jessica P Autschbach, Ruediger Moza, Ajay Aljalloud, Ali Conventional Prostheses versus Sutureless Perceval for Aortic Valve Replacement: A Meta-Analysis |
title | Conventional Prostheses versus Sutureless Perceval for Aortic Valve Replacement: A Meta-Analysis |
title_full | Conventional Prostheses versus Sutureless Perceval for Aortic Valve Replacement: A Meta-Analysis |
title_fullStr | Conventional Prostheses versus Sutureless Perceval for Aortic Valve Replacement: A Meta-Analysis |
title_full_unstemmed | Conventional Prostheses versus Sutureless Perceval for Aortic Valve Replacement: A Meta-Analysis |
title_short | Conventional Prostheses versus Sutureless Perceval for Aortic Valve Replacement: A Meta-Analysis |
title_sort | conventional prostheses versus sutureless perceval for aortic valve replacement: a meta-analysis |
topic | Review Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10284666/ https://www.ncbi.nlm.nih.gov/pubmed/36517036 http://dx.doi.org/10.5761/atcs.ra.22-00125 |
work_keys_str_mv | AT colarossigiorgia conventionalprosthesesversussuturelesspercevalforaorticvalvereplacementametaanalysis AT migliorinifilippo conventionalprosthesesversussuturelesspercevalforaorticvalvereplacementametaanalysis AT beckermichael conventionalprosthesesversussuturelesspercevalforaorticvalvereplacementametaanalysis AT ariasjessicap conventionalprosthesesversussuturelesspercevalforaorticvalvereplacementametaanalysis AT autschbachruediger conventionalprosthesesversussuturelesspercevalforaorticvalvereplacementametaanalysis AT mozaajay conventionalprosthesesversussuturelesspercevalforaorticvalvereplacementametaanalysis AT aljalloudali conventionalprosthesesversussuturelesspercevalforaorticvalvereplacementametaanalysis |