Cargando…

Biomechanical evaluation of a novel biomimetic artificial intervertebral disc in canine cervical cadaveric spines

BACKGROUND CONTEXT: Cervical disc replacement (CDR) aims to restore motion of the treated level to reduce the risk of adjacent segment disease (ASD) compared with spinal fusion. However, first‐generation articulating devices are unable to mimic the complex deformation kinematics of a natural disc. T...

Descripción completa

Detalles Bibliográficos
Autores principales: Jacobs, Celien A. M., Doodkorte, Remco J. P., Kamali, S. Amir, Abdelgawad, Abdelrahman M., Ghazanfari, Samaneh, Jockenhoevel, Stefan, Arts, J. J. Chris, Tryfonidou, Marianna A., Meij, Björn P., Ito, Keita
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley & Sons, Inc. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10285750/
https://www.ncbi.nlm.nih.gov/pubmed/37361332
http://dx.doi.org/10.1002/jsp2.1251
_version_ 1785061671000080384
author Jacobs, Celien A. M.
Doodkorte, Remco J. P.
Kamali, S. Amir
Abdelgawad, Abdelrahman M.
Ghazanfari, Samaneh
Jockenhoevel, Stefan
Arts, J. J. Chris
Tryfonidou, Marianna A.
Meij, Björn P.
Ito, Keita
author_facet Jacobs, Celien A. M.
Doodkorte, Remco J. P.
Kamali, S. Amir
Abdelgawad, Abdelrahman M.
Ghazanfari, Samaneh
Jockenhoevel, Stefan
Arts, J. J. Chris
Tryfonidou, Marianna A.
Meij, Björn P.
Ito, Keita
author_sort Jacobs, Celien A. M.
collection PubMed
description BACKGROUND CONTEXT: Cervical disc replacement (CDR) aims to restore motion of the treated level to reduce the risk of adjacent segment disease (ASD) compared with spinal fusion. However, first‐generation articulating devices are unable to mimic the complex deformation kinematics of a natural disc. Thus, a biomimetic artificial intervertebral CDR (bioAID), containing a hydroxyethylmethacrylate (HEMA)—sodium methacrylate (NaMA) hydrogel core representing the nucleus pulposus, an ultra‐high‐molecular‐weight‐polyethylene fiber jacket as annulus fibrosus, and titanium endplates with pins for primary mechanical fixation, was developed. PURPOSE: To assess the initial biomechanical effect of the bioAID on the kinematic behavior of the canine spine, an ex vivo biomechanical study in 6‐degrees‐of‐freedom was performed. STUDY DESIGN: A canine cadaveric biomechanical study. METHODS: Six cadaveric canine specimens (C3‐C6) were tested in flexion‐extension (FE), lateral bending (LB) axial rotation (AR) using a spine tester in three conditions: intact, after C4‐C5 disc replacement with bioAID, and after C4‐C5 interbody fusion. A hybrid protocol was used where first the intact spines were subjected to a pure moment of ±1 Nm, whereafter the treated spines were subjected to the full range of motion (ROM) of the intact condition. 3D segmental motions at all levels were measured while recording the reaction torsion. Biomechanical parameters studied included ROM, neutral zone (NZ), and intradiscal pressure (IDP) at the adjacent cranial level (C3‐C4). RESULTS: The bioAID retained the sigmoid shape of the moment‐rotation curves with a NZ similar to the intact condition in LB and FE. Additionally, the normalized ROMs at the bioAID‐treated level were statistically equivalent to intact during FE and AR while slightly decreased in LB. At the two adjacent levels, ROMs showed similar values for the intact compared to the bioAID for FE and AR and an increase in LB. In contrast, levels adjacent to the fused segment showed an increased motion in FE and LB as compensation for the loss of motion at the treated level. The IDP at the adjacent C3‐C4 level after implantation of bioAID was close to intact values. After fusion, increased IDP was found compared with intact but did not reach statistical significance. CONCLUSION: This study indicates that the bioAID can mimic the kinematic behavior of the replaced intervertebral disc and preserves that for the adjacent levels better than fusion. As a result, CDR using the novel bioAID is a promising alternative treatment for replacing severely degenerated intervertebral discs.
format Online
Article
Text
id pubmed-10285750
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher John Wiley & Sons, Inc.
record_format MEDLINE/PubMed
spelling pubmed-102857502023-06-23 Biomechanical evaluation of a novel biomimetic artificial intervertebral disc in canine cervical cadaveric spines Jacobs, Celien A. M. Doodkorte, Remco J. P. Kamali, S. Amir Abdelgawad, Abdelrahman M. Ghazanfari, Samaneh Jockenhoevel, Stefan Arts, J. J. Chris Tryfonidou, Marianna A. Meij, Björn P. Ito, Keita JOR Spine Research Articles BACKGROUND CONTEXT: Cervical disc replacement (CDR) aims to restore motion of the treated level to reduce the risk of adjacent segment disease (ASD) compared with spinal fusion. However, first‐generation articulating devices are unable to mimic the complex deformation kinematics of a natural disc. Thus, a biomimetic artificial intervertebral CDR (bioAID), containing a hydroxyethylmethacrylate (HEMA)—sodium methacrylate (NaMA) hydrogel core representing the nucleus pulposus, an ultra‐high‐molecular‐weight‐polyethylene fiber jacket as annulus fibrosus, and titanium endplates with pins for primary mechanical fixation, was developed. PURPOSE: To assess the initial biomechanical effect of the bioAID on the kinematic behavior of the canine spine, an ex vivo biomechanical study in 6‐degrees‐of‐freedom was performed. STUDY DESIGN: A canine cadaveric biomechanical study. METHODS: Six cadaveric canine specimens (C3‐C6) were tested in flexion‐extension (FE), lateral bending (LB) axial rotation (AR) using a spine tester in three conditions: intact, after C4‐C5 disc replacement with bioAID, and after C4‐C5 interbody fusion. A hybrid protocol was used where first the intact spines were subjected to a pure moment of ±1 Nm, whereafter the treated spines were subjected to the full range of motion (ROM) of the intact condition. 3D segmental motions at all levels were measured while recording the reaction torsion. Biomechanical parameters studied included ROM, neutral zone (NZ), and intradiscal pressure (IDP) at the adjacent cranial level (C3‐C4). RESULTS: The bioAID retained the sigmoid shape of the moment‐rotation curves with a NZ similar to the intact condition in LB and FE. Additionally, the normalized ROMs at the bioAID‐treated level were statistically equivalent to intact during FE and AR while slightly decreased in LB. At the two adjacent levels, ROMs showed similar values for the intact compared to the bioAID for FE and AR and an increase in LB. In contrast, levels adjacent to the fused segment showed an increased motion in FE and LB as compensation for the loss of motion at the treated level. The IDP at the adjacent C3‐C4 level after implantation of bioAID was close to intact values. After fusion, increased IDP was found compared with intact but did not reach statistical significance. CONCLUSION: This study indicates that the bioAID can mimic the kinematic behavior of the replaced intervertebral disc and preserves that for the adjacent levels better than fusion. As a result, CDR using the novel bioAID is a promising alternative treatment for replacing severely degenerated intervertebral discs. John Wiley & Sons, Inc. 2023-02-21 /pmc/articles/PMC10285750/ /pubmed/37361332 http://dx.doi.org/10.1002/jsp2.1251 Text en © 2023 The Authors. JOR Spine published by Wiley Periodicals LLC on behalf of Orthopaedic Research Society. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Articles
Jacobs, Celien A. M.
Doodkorte, Remco J. P.
Kamali, S. Amir
Abdelgawad, Abdelrahman M.
Ghazanfari, Samaneh
Jockenhoevel, Stefan
Arts, J. J. Chris
Tryfonidou, Marianna A.
Meij, Björn P.
Ito, Keita
Biomechanical evaluation of a novel biomimetic artificial intervertebral disc in canine cervical cadaveric spines
title Biomechanical evaluation of a novel biomimetic artificial intervertebral disc in canine cervical cadaveric spines
title_full Biomechanical evaluation of a novel biomimetic artificial intervertebral disc in canine cervical cadaveric spines
title_fullStr Biomechanical evaluation of a novel biomimetic artificial intervertebral disc in canine cervical cadaveric spines
title_full_unstemmed Biomechanical evaluation of a novel biomimetic artificial intervertebral disc in canine cervical cadaveric spines
title_short Biomechanical evaluation of a novel biomimetic artificial intervertebral disc in canine cervical cadaveric spines
title_sort biomechanical evaluation of a novel biomimetic artificial intervertebral disc in canine cervical cadaveric spines
topic Research Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10285750/
https://www.ncbi.nlm.nih.gov/pubmed/37361332
http://dx.doi.org/10.1002/jsp2.1251
work_keys_str_mv AT jacobscelienam biomechanicalevaluationofanovelbiomimeticartificialintervertebraldiscincaninecervicalcadavericspines
AT doodkorteremcojp biomechanicalevaluationofanovelbiomimeticartificialintervertebraldiscincaninecervicalcadavericspines
AT kamalisamir biomechanicalevaluationofanovelbiomimeticartificialintervertebraldiscincaninecervicalcadavericspines
AT abdelgawadabdelrahmanm biomechanicalevaluationofanovelbiomimeticartificialintervertebraldiscincaninecervicalcadavericspines
AT ghazanfarisamaneh biomechanicalevaluationofanovelbiomimeticartificialintervertebraldiscincaninecervicalcadavericspines
AT jockenhoevelstefan biomechanicalevaluationofanovelbiomimeticartificialintervertebraldiscincaninecervicalcadavericspines
AT artsjjchris biomechanicalevaluationofanovelbiomimeticartificialintervertebraldiscincaninecervicalcadavericspines
AT tryfonidoumariannaa biomechanicalevaluationofanovelbiomimeticartificialintervertebraldiscincaninecervicalcadavericspines
AT meijbjornp biomechanicalevaluationofanovelbiomimeticartificialintervertebraldiscincaninecervicalcadavericspines
AT itokeita biomechanicalevaluationofanovelbiomimeticartificialintervertebraldiscincaninecervicalcadavericspines