Cargando…
Optimizing extinguishing angle of 6MF-30 pneumatic extinguisher for wildland fire-fighting based on CFD and experiments
The 6MF-30 pneumatic extinguisher is a widely utilized and efficient tool for combating wildland fires. However, using incorrect extinguishing angles can diminish its effectiveness. This study aimed to determine the optimal extinguishing angle for the 6MF-30 pneumatic extinguisher by conducting comp...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10287740/ https://www.ncbi.nlm.nih.gov/pubmed/37349478 http://dx.doi.org/10.1038/s41598-023-37275-x |
_version_ | 1785061938486575104 |
---|---|
author | Chen, Fanbao Miao, Bin Wang, Qingbiao |
author_facet | Chen, Fanbao Miao, Bin Wang, Qingbiao |
author_sort | Chen, Fanbao |
collection | PubMed |
description | The 6MF-30 pneumatic extinguisher is a widely utilized and efficient tool for combating wildland fires. However, using incorrect extinguishing angles can diminish its effectiveness. This study aimed to determine the optimal extinguishing angle for the 6MF-30 pneumatic extinguisher by conducting computational fluid dynamics simulations and experimental verification. The findings revealed that ground roughness did not significantly affect the optimal extinguishing angle or the attenuation of jet velocity near the fan outlet region. The study determined that an optimal extinguishing angle of 37° applies to lossless ground, natural grassland, grassland with artificial disturbance, and enclosed grassland. Furthermore, among the selected angles, the highest rate of jet velocity reduction was observed at 45°, whereas the slowest reduction occurred at 20° and 25°. These findings offer valuable insights and recommendations for enhancing the efficacy of wildland fire-fighting when employing the 6MF-30 pneumatic extinguisher. |
format | Online Article Text |
id | pubmed-10287740 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-102877402023-06-24 Optimizing extinguishing angle of 6MF-30 pneumatic extinguisher for wildland fire-fighting based on CFD and experiments Chen, Fanbao Miao, Bin Wang, Qingbiao Sci Rep Article The 6MF-30 pneumatic extinguisher is a widely utilized and efficient tool for combating wildland fires. However, using incorrect extinguishing angles can diminish its effectiveness. This study aimed to determine the optimal extinguishing angle for the 6MF-30 pneumatic extinguisher by conducting computational fluid dynamics simulations and experimental verification. The findings revealed that ground roughness did not significantly affect the optimal extinguishing angle or the attenuation of jet velocity near the fan outlet region. The study determined that an optimal extinguishing angle of 37° applies to lossless ground, natural grassland, grassland with artificial disturbance, and enclosed grassland. Furthermore, among the selected angles, the highest rate of jet velocity reduction was observed at 45°, whereas the slowest reduction occurred at 20° and 25°. These findings offer valuable insights and recommendations for enhancing the efficacy of wildland fire-fighting when employing the 6MF-30 pneumatic extinguisher. Nature Publishing Group UK 2023-06-22 /pmc/articles/PMC10287740/ /pubmed/37349478 http://dx.doi.org/10.1038/s41598-023-37275-x Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Chen, Fanbao Miao, Bin Wang, Qingbiao Optimizing extinguishing angle of 6MF-30 pneumatic extinguisher for wildland fire-fighting based on CFD and experiments |
title | Optimizing extinguishing angle of 6MF-30 pneumatic extinguisher for wildland fire-fighting based on CFD and experiments |
title_full | Optimizing extinguishing angle of 6MF-30 pneumatic extinguisher for wildland fire-fighting based on CFD and experiments |
title_fullStr | Optimizing extinguishing angle of 6MF-30 pneumatic extinguisher for wildland fire-fighting based on CFD and experiments |
title_full_unstemmed | Optimizing extinguishing angle of 6MF-30 pneumatic extinguisher for wildland fire-fighting based on CFD and experiments |
title_short | Optimizing extinguishing angle of 6MF-30 pneumatic extinguisher for wildland fire-fighting based on CFD and experiments |
title_sort | optimizing extinguishing angle of 6mf-30 pneumatic extinguisher for wildland fire-fighting based on cfd and experiments |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10287740/ https://www.ncbi.nlm.nih.gov/pubmed/37349478 http://dx.doi.org/10.1038/s41598-023-37275-x |
work_keys_str_mv | AT chenfanbao optimizingextinguishingangleof6mf30pneumaticextinguisherforwildlandfirefightingbasedoncfdandexperiments AT miaobin optimizingextinguishingangleof6mf30pneumaticextinguisherforwildlandfirefightingbasedoncfdandexperiments AT wangqingbiao optimizingextinguishingangleof6mf30pneumaticextinguisherforwildlandfirefightingbasedoncfdandexperiments |