Cargando…
Axillary skin crease incision versus conventional posterolateral incision in open repair of patent ductus arteriosus for extremely low birth weight infants: a retrospective study
BACKGROUND: Thoracotomy with posterolateral incision (PLI) is commonly used for surgical repair of patent ductus arteriosus (PDA) in extremely low birth weight (ELBW) infants. Some reports have described thoracotomy for PDA using an axillary skin crease incision (ASCI) in consideration of cosmetic p...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10288708/ https://www.ncbi.nlm.nih.gov/pubmed/37349731 http://dx.doi.org/10.1186/s12893-023-02081-9 |
_version_ | 1785062126884225024 |
---|---|
author | Okamoto, Mitsumasa Tsuruno, Yudai Fukuzawa, Hiroaki |
author_facet | Okamoto, Mitsumasa Tsuruno, Yudai Fukuzawa, Hiroaki |
author_sort | Okamoto, Mitsumasa |
collection | PubMed |
description | BACKGROUND: Thoracotomy with posterolateral incision (PLI) is commonly used for surgical repair of patent ductus arteriosus (PDA) in extremely low birth weight (ELBW) infants. Some reports have described thoracotomy for PDA using an axillary skin crease incision (ASCI) in consideration of cosmetic problems such as surgical wounds and thoracic deformities, but the details remain unclear. METHODS: In this study, we performed clipping ligation by thoracotomy with ASCI for ELBW infants with PDA from 2011 to 2015 for the purpose of improving cosmetic results, and retrospectively compared the results with those for conventional PLI cases performed from 2016 to 2020. RESULTS: ASCI was found to be associated with serious surgical complications and showed a significant difference in outcome parameters only for surgery time, suggesting a safety problem for ASCI. Considering these results, PLI allows clipping of the nearby PDA from the thoracotomy wound while looking straight ahead, whereas the PDA in ASCI is positioned deep and oblique to the thoracotomy wound, so the clipping angle is limited and accurate completion of the procedure is difficult. CONCLUSIONS: Regarding PDA repair in ELBW infants, ASCI shows a high risk of serious surgical complications. Conventional PLI remains preferable for safe and accurate results. |
format | Online Article Text |
id | pubmed-10288708 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-102887082023-06-24 Axillary skin crease incision versus conventional posterolateral incision in open repair of patent ductus arteriosus for extremely low birth weight infants: a retrospective study Okamoto, Mitsumasa Tsuruno, Yudai Fukuzawa, Hiroaki BMC Surg Research BACKGROUND: Thoracotomy with posterolateral incision (PLI) is commonly used for surgical repair of patent ductus arteriosus (PDA) in extremely low birth weight (ELBW) infants. Some reports have described thoracotomy for PDA using an axillary skin crease incision (ASCI) in consideration of cosmetic problems such as surgical wounds and thoracic deformities, but the details remain unclear. METHODS: In this study, we performed clipping ligation by thoracotomy with ASCI for ELBW infants with PDA from 2011 to 2015 for the purpose of improving cosmetic results, and retrospectively compared the results with those for conventional PLI cases performed from 2016 to 2020. RESULTS: ASCI was found to be associated with serious surgical complications and showed a significant difference in outcome parameters only for surgery time, suggesting a safety problem for ASCI. Considering these results, PLI allows clipping of the nearby PDA from the thoracotomy wound while looking straight ahead, whereas the PDA in ASCI is positioned deep and oblique to the thoracotomy wound, so the clipping angle is limited and accurate completion of the procedure is difficult. CONCLUSIONS: Regarding PDA repair in ELBW infants, ASCI shows a high risk of serious surgical complications. Conventional PLI remains preferable for safe and accurate results. BioMed Central 2023-06-23 /pmc/articles/PMC10288708/ /pubmed/37349731 http://dx.doi.org/10.1186/s12893-023-02081-9 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Okamoto, Mitsumasa Tsuruno, Yudai Fukuzawa, Hiroaki Axillary skin crease incision versus conventional posterolateral incision in open repair of patent ductus arteriosus for extremely low birth weight infants: a retrospective study |
title | Axillary skin crease incision versus conventional posterolateral incision in open repair of patent ductus arteriosus for extremely low birth weight infants: a retrospective study |
title_full | Axillary skin crease incision versus conventional posterolateral incision in open repair of patent ductus arteriosus for extremely low birth weight infants: a retrospective study |
title_fullStr | Axillary skin crease incision versus conventional posterolateral incision in open repair of patent ductus arteriosus for extremely low birth weight infants: a retrospective study |
title_full_unstemmed | Axillary skin crease incision versus conventional posterolateral incision in open repair of patent ductus arteriosus for extremely low birth weight infants: a retrospective study |
title_short | Axillary skin crease incision versus conventional posterolateral incision in open repair of patent ductus arteriosus for extremely low birth weight infants: a retrospective study |
title_sort | axillary skin crease incision versus conventional posterolateral incision in open repair of patent ductus arteriosus for extremely low birth weight infants: a retrospective study |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10288708/ https://www.ncbi.nlm.nih.gov/pubmed/37349731 http://dx.doi.org/10.1186/s12893-023-02081-9 |
work_keys_str_mv | AT okamotomitsumasa axillaryskincreaseincisionversusconventionalposterolateralincisioninopenrepairofpatentductusarteriosusforextremelylowbirthweightinfantsaretrospectivestudy AT tsurunoyudai axillaryskincreaseincisionversusconventionalposterolateralincisioninopenrepairofpatentductusarteriosusforextremelylowbirthweightinfantsaretrospectivestudy AT fukuzawahiroaki axillaryskincreaseincisionversusconventionalposterolateralincisioninopenrepairofpatentductusarteriosusforextremelylowbirthweightinfantsaretrospectivestudy |