Risk factors for medical device-related pressure injury in ICU patients: A systematic review and meta-analysis

BACKGROUND: Medical device-related pressure injury (MDRPI) in intensive care unit (ICU) patients is a serious issue. We aimed to evaluate the risk factors for MDRPI associated with ICU patients through systematic review and meta-analysis, and provide insights into the clinical prevention of MDRPI. M...

Descripción completa

Detalles Bibliográficos
Autores principales: Gou, Ling, Zhang, Zhiqin, A., Yongde
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10289390/
https://www.ncbi.nlm.nih.gov/pubmed/37352180
http://dx.doi.org/10.1371/journal.pone.0287326
_version_ 1785062267093516288
author Gou, Ling
Zhang, Zhiqin
A., Yongde
author_facet Gou, Ling
Zhang, Zhiqin
A., Yongde
author_sort Gou, Ling
collection PubMed
description BACKGROUND: Medical device-related pressure injury (MDRPI) in intensive care unit (ICU) patients is a serious issue. We aimed to evaluate the risk factors for MDRPI associated with ICU patients through systematic review and meta-analysis, and provide insights into the clinical prevention of MDRPI. METHODS: We searched PubMed, Embase, Web of Science, China National Knowledge Infrastructure (CNKI), WanFang Database, and China BioMedical Literature Database (CBM) (from inception to January 2023) for studies that identified risk factors of MDRPI in ICU patients. In order to avoid the omission of relevant literature, we performed a secondary search of the above database on February 15, 2023. Meta-analysis was performed using Revman 5.3. RESULTS: Fifteen studies involving 4850 participants were selected to analyze risk factors for MDRPI in ICU patients. While conducting a meta-analysis, we used sensitivity analysis to ensure the reliability of the results for cases with significant heterogeneity among studies. When the source of heterogeneity cannot be determined, we only described the risk factor. The risk factors for MDRPI in ICU patients were elder age (OR = 1.06, 95% CI: 1.03–1.10), diabetes mellitus (OR = 3.20, 95% CI: 1.96–5.21), edema (OR = 3.62, 95% CI: 2.31–5.67), lower Braden scale score (OR = 1.22, 95%CI: 1.11–1.33), higher SOFA score (OR = 4.21, 95%CI: 2.38–7.47), higher APACHE II score (OR = 1.38, 95%CI: 1.15–1.64), longer usage time of medical devices (OR = 1.11, 95%CI: 1.05–1.19), use of vasoconstrictors (OR = 6.07, 95%CI: 3.15–11.69), surgery (OR = 4.36, 95% CI: 2.07–9.15), prone position (OR = 24.71, 95% CI: 7.34–83.15), and prone position ventilation (OR = 17.51, 95% CI: 5.86–52.36). Furthermore, we found that ICU patients who used subglottic suction catheters had a higher risk of MDRPI, whereas ICU patients with higher hemoglobin and serum albumin levels had a lower risk of MDRPI. CONCLUSION: This study reported the risk factors for MDRPI in ICU patients. A comprehensive analysis of these risk factors will help to prevent and optimize interventions, thereby minimizing the occurrence of MDRPI.
format Online
Article
Text
id pubmed-10289390
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-102893902023-06-24 Risk factors for medical device-related pressure injury in ICU patients: A systematic review and meta-analysis Gou, Ling Zhang, Zhiqin A., Yongde PLoS One Research Article BACKGROUND: Medical device-related pressure injury (MDRPI) in intensive care unit (ICU) patients is a serious issue. We aimed to evaluate the risk factors for MDRPI associated with ICU patients through systematic review and meta-analysis, and provide insights into the clinical prevention of MDRPI. METHODS: We searched PubMed, Embase, Web of Science, China National Knowledge Infrastructure (CNKI), WanFang Database, and China BioMedical Literature Database (CBM) (from inception to January 2023) for studies that identified risk factors of MDRPI in ICU patients. In order to avoid the omission of relevant literature, we performed a secondary search of the above database on February 15, 2023. Meta-analysis was performed using Revman 5.3. RESULTS: Fifteen studies involving 4850 participants were selected to analyze risk factors for MDRPI in ICU patients. While conducting a meta-analysis, we used sensitivity analysis to ensure the reliability of the results for cases with significant heterogeneity among studies. When the source of heterogeneity cannot be determined, we only described the risk factor. The risk factors for MDRPI in ICU patients were elder age (OR = 1.06, 95% CI: 1.03–1.10), diabetes mellitus (OR = 3.20, 95% CI: 1.96–5.21), edema (OR = 3.62, 95% CI: 2.31–5.67), lower Braden scale score (OR = 1.22, 95%CI: 1.11–1.33), higher SOFA score (OR = 4.21, 95%CI: 2.38–7.47), higher APACHE II score (OR = 1.38, 95%CI: 1.15–1.64), longer usage time of medical devices (OR = 1.11, 95%CI: 1.05–1.19), use of vasoconstrictors (OR = 6.07, 95%CI: 3.15–11.69), surgery (OR = 4.36, 95% CI: 2.07–9.15), prone position (OR = 24.71, 95% CI: 7.34–83.15), and prone position ventilation (OR = 17.51, 95% CI: 5.86–52.36). Furthermore, we found that ICU patients who used subglottic suction catheters had a higher risk of MDRPI, whereas ICU patients with higher hemoglobin and serum albumin levels had a lower risk of MDRPI. CONCLUSION: This study reported the risk factors for MDRPI in ICU patients. A comprehensive analysis of these risk factors will help to prevent and optimize interventions, thereby minimizing the occurrence of MDRPI. Public Library of Science 2023-06-23 /pmc/articles/PMC10289390/ /pubmed/37352180 http://dx.doi.org/10.1371/journal.pone.0287326 Text en © 2023 Gou et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Gou, Ling
Zhang, Zhiqin
A., Yongde
Risk factors for medical device-related pressure injury in ICU patients: A systematic review and meta-analysis
title Risk factors for medical device-related pressure injury in ICU patients: A systematic review and meta-analysis
title_full Risk factors for medical device-related pressure injury in ICU patients: A systematic review and meta-analysis
title_fullStr Risk factors for medical device-related pressure injury in ICU patients: A systematic review and meta-analysis
title_full_unstemmed Risk factors for medical device-related pressure injury in ICU patients: A systematic review and meta-analysis
title_short Risk factors for medical device-related pressure injury in ICU patients: A systematic review and meta-analysis
title_sort risk factors for medical device-related pressure injury in icu patients: a systematic review and meta-analysis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10289390/
https://www.ncbi.nlm.nih.gov/pubmed/37352180
http://dx.doi.org/10.1371/journal.pone.0287326
work_keys_str_mv AT gouling riskfactorsformedicaldevicerelatedpressureinjuryinicupatientsasystematicreviewandmetaanalysis
AT zhangzhiqin riskfactorsformedicaldevicerelatedpressureinjuryinicupatientsasystematicreviewandmetaanalysis
AT ayongde riskfactorsformedicaldevicerelatedpressureinjuryinicupatientsasystematicreviewandmetaanalysis