Maxillary labial peri-implant hard and soft tissue alteration observed on cross-sectional dimension: a 2-year prospective observational study
OBJECTIVES: To evaluate how peri-implant hard and soft tissue height (BH, MH) alter after final prostheses placement related to labial hard and soft tissue thickness (BW, MW). MATERIALS AND METHODS: Forty-five platform-switched implants were classified into four groups according to BW and MW: type 1...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10290020/ https://www.ncbi.nlm.nih.gov/pubmed/37351804 http://dx.doi.org/10.1186/s40729-023-00477-z |
_version_ | 1785062402370306048 |
---|---|
author | Yamada, Shuhei Nakano, Tamaki Kobayashi, Tomoyuki Ishigaki, Shoichi |
author_facet | Yamada, Shuhei Nakano, Tamaki Kobayashi, Tomoyuki Ishigaki, Shoichi |
author_sort | Yamada, Shuhei |
collection | PubMed |
description | OBJECTIVES: To evaluate how peri-implant hard and soft tissue height (BH, MH) alter after final prostheses placement related to labial hard and soft tissue thickness (BW, MW). MATERIALS AND METHODS: Forty-five platform-switched implants were classified into four groups according to BW and MW: type 1 (thick BW and thick MW), type 2 (thick BW and thin MW), type 3 (thin BW and thick MW), type 4 (thin BW and thin MW). Tissue resorption was evaluated on cone-beam CT images taken at final prostheses placement, at 1-year follow-up, and at 2-year follow-up. Kruskal–Wallis test and post hoc Mann–Whitney test were applied; significance was set to 0.05. RESULTS: BH resorption was 0.13 ± 0.12 mm in type 1, 0.26 ± 0.17 mm in type 2, 0.09 ± 0.09 mm in type 3, 0.94 ± 0.19 mm in type 4. Differences between type 1 and 4, type 2 and 4, and type 3 and 4 were statistically significant (p < 0.001, p = 0.005, p < 0.001, respectively). MH resorption was 0.10 ± 0.09 mm in type 1, 0.36 ± 0.16 mm in type 2, 0.12 ± 0.12 mm in Type 3, 0.79 ± 0.23 mm in type 4. Differences between type 1 and 2, type 1 and 4, type 2 and 3, type 2 and 4 and type 3 and 4 were statistically significant (p < 0.001). CONCLUSIONS: Significantly less BH/MH resorption occurs around implants with thick BW/MW than those with thin BW/MW in 2 years. Implants with thick peri-implant soft tissue resulted in significantly less tissue resorption in second year after final prostheses placement. |
format | Online Article Text |
id | pubmed-10290020 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-102900202023-06-25 Maxillary labial peri-implant hard and soft tissue alteration observed on cross-sectional dimension: a 2-year prospective observational study Yamada, Shuhei Nakano, Tamaki Kobayashi, Tomoyuki Ishigaki, Shoichi Int J Implant Dent Research OBJECTIVES: To evaluate how peri-implant hard and soft tissue height (BH, MH) alter after final prostheses placement related to labial hard and soft tissue thickness (BW, MW). MATERIALS AND METHODS: Forty-five platform-switched implants were classified into four groups according to BW and MW: type 1 (thick BW and thick MW), type 2 (thick BW and thin MW), type 3 (thin BW and thick MW), type 4 (thin BW and thin MW). Tissue resorption was evaluated on cone-beam CT images taken at final prostheses placement, at 1-year follow-up, and at 2-year follow-up. Kruskal–Wallis test and post hoc Mann–Whitney test were applied; significance was set to 0.05. RESULTS: BH resorption was 0.13 ± 0.12 mm in type 1, 0.26 ± 0.17 mm in type 2, 0.09 ± 0.09 mm in type 3, 0.94 ± 0.19 mm in type 4. Differences between type 1 and 4, type 2 and 4, and type 3 and 4 were statistically significant (p < 0.001, p = 0.005, p < 0.001, respectively). MH resorption was 0.10 ± 0.09 mm in type 1, 0.36 ± 0.16 mm in type 2, 0.12 ± 0.12 mm in Type 3, 0.79 ± 0.23 mm in type 4. Differences between type 1 and 2, type 1 and 4, type 2 and 3, type 2 and 4 and type 3 and 4 were statistically significant (p < 0.001). CONCLUSIONS: Significantly less BH/MH resorption occurs around implants with thick BW/MW than those with thin BW/MW in 2 years. Implants with thick peri-implant soft tissue resulted in significantly less tissue resorption in second year after final prostheses placement. Springer Berlin Heidelberg 2023-06-23 /pmc/articles/PMC10290020/ /pubmed/37351804 http://dx.doi.org/10.1186/s40729-023-00477-z Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Research Yamada, Shuhei Nakano, Tamaki Kobayashi, Tomoyuki Ishigaki, Shoichi Maxillary labial peri-implant hard and soft tissue alteration observed on cross-sectional dimension: a 2-year prospective observational study |
title | Maxillary labial peri-implant hard and soft tissue alteration observed on cross-sectional dimension: a 2-year prospective observational study |
title_full | Maxillary labial peri-implant hard and soft tissue alteration observed on cross-sectional dimension: a 2-year prospective observational study |
title_fullStr | Maxillary labial peri-implant hard and soft tissue alteration observed on cross-sectional dimension: a 2-year prospective observational study |
title_full_unstemmed | Maxillary labial peri-implant hard and soft tissue alteration observed on cross-sectional dimension: a 2-year prospective observational study |
title_short | Maxillary labial peri-implant hard and soft tissue alteration observed on cross-sectional dimension: a 2-year prospective observational study |
title_sort | maxillary labial peri-implant hard and soft tissue alteration observed on cross-sectional dimension: a 2-year prospective observational study |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10290020/ https://www.ncbi.nlm.nih.gov/pubmed/37351804 http://dx.doi.org/10.1186/s40729-023-00477-z |
work_keys_str_mv | AT yamadashuhei maxillarylabialperiimplanthardandsofttissuealterationobservedoncrosssectionaldimensiona2yearprospectiveobservationalstudy AT nakanotamaki maxillarylabialperiimplanthardandsofttissuealterationobservedoncrosssectionaldimensiona2yearprospectiveobservationalstudy AT kobayashitomoyuki maxillarylabialperiimplanthardandsofttissuealterationobservedoncrosssectionaldimensiona2yearprospectiveobservationalstudy AT ishigakishoichi maxillarylabialperiimplanthardandsofttissuealterationobservedoncrosssectionaldimensiona2yearprospectiveobservationalstudy |