Cargando…

Biomechanical effect of proximal multifidus injury on adjacent segments during posterior lumbar interbody fusion: a finite element study

BACKGROUND: Adjacent segment degeneration (ASD) is a common complication of lumbar interbody fusion; the paraspinal muscles significantly maintain spinal biomechanical stability. This study aims to investigate the biomechanical effects of proximal multifidus injury on adjacent segments during poster...

Descripción completa

Detalles Bibliográficos
Autores principales: Wei, Wei, Wang, Tianhao, Liu, Jianheng, Mao, Keya, Pan, Chun’ang, Li, Hui, Zhao, Yongfei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10290411/
https://www.ncbi.nlm.nih.gov/pubmed/37355581
http://dx.doi.org/10.1186/s12891-023-06649-7
_version_ 1785062491576860672
author Wei, Wei
Wang, Tianhao
Liu, Jianheng
Mao, Keya
Pan, Chun’ang
Li, Hui
Zhao, Yongfei
author_facet Wei, Wei
Wang, Tianhao
Liu, Jianheng
Mao, Keya
Pan, Chun’ang
Li, Hui
Zhao, Yongfei
author_sort Wei, Wei
collection PubMed
description BACKGROUND: Adjacent segment degeneration (ASD) is a common complication of lumbar interbody fusion; the paraspinal muscles significantly maintain spinal biomechanical stability. This study aims to investigate the biomechanical effects of proximal multifidus injury on adjacent segments during posterior lumbar interbody fusion (PLIF). METHODS: Data from a lumbosacral vertebral computed tomography scan of a healthy adult male volunteer were used to establish a normal lumbosacral vertebral finite element model and load the muscle force of the multifidus. A normal model, an L4/5 PLIF model (PFM) based on a preserved proximal multifidus, a total laminectomy PLIF model (TLPFM), and a hemi-laminectomy PLIF model based on a severed proximal multifidus were established, respectively. The range of motion (ROM) and maximum von Mises stress of the upper and lower adjacent segments were analyzed along with the total work of the multifidus muscle force. RESULTS: This model verified that the ROMs of all segments with four degrees of freedom were similar to those obtained in previous research data, which validated the model. PLIF resulted in an increased ROM and maximum von Mises stress in the upper and lower adjacent segments. The ROM and maximum von Mises stress in the TLPFM were most evident in the upper adjacent segment, except for lateral bending. The ROM of the lower adjacent segment increased most significantly in the PFM in flexion and extension and increased most significantly in the TLPFM in lateral bending and axial rotation, whereas the maximum von Mises stress of the lower adjacent segment increased the most in the TLPFM, except in flexion. The muscle force and work of the multifidus were the greatest in the TLPFM. CONCLUSIONS: PLIF increased the ROM and maximum von Mises stress in adjacent cranial segments. The preservation of the proximal multifidus muscle contributes to the maintenance of the physiological mechanical behavior of adjacent segments, thus preventing the occurrence and development of ASD.
format Online
Article
Text
id pubmed-10290411
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-102904112023-06-25 Biomechanical effect of proximal multifidus injury on adjacent segments during posterior lumbar interbody fusion: a finite element study Wei, Wei Wang, Tianhao Liu, Jianheng Mao, Keya Pan, Chun’ang Li, Hui Zhao, Yongfei BMC Musculoskelet Disord Research BACKGROUND: Adjacent segment degeneration (ASD) is a common complication of lumbar interbody fusion; the paraspinal muscles significantly maintain spinal biomechanical stability. This study aims to investigate the biomechanical effects of proximal multifidus injury on adjacent segments during posterior lumbar interbody fusion (PLIF). METHODS: Data from a lumbosacral vertebral computed tomography scan of a healthy adult male volunteer were used to establish a normal lumbosacral vertebral finite element model and load the muscle force of the multifidus. A normal model, an L4/5 PLIF model (PFM) based on a preserved proximal multifidus, a total laminectomy PLIF model (TLPFM), and a hemi-laminectomy PLIF model based on a severed proximal multifidus were established, respectively. The range of motion (ROM) and maximum von Mises stress of the upper and lower adjacent segments were analyzed along with the total work of the multifidus muscle force. RESULTS: This model verified that the ROMs of all segments with four degrees of freedom were similar to those obtained in previous research data, which validated the model. PLIF resulted in an increased ROM and maximum von Mises stress in the upper and lower adjacent segments. The ROM and maximum von Mises stress in the TLPFM were most evident in the upper adjacent segment, except for lateral bending. The ROM of the lower adjacent segment increased most significantly in the PFM in flexion and extension and increased most significantly in the TLPFM in lateral bending and axial rotation, whereas the maximum von Mises stress of the lower adjacent segment increased the most in the TLPFM, except in flexion. The muscle force and work of the multifidus were the greatest in the TLPFM. CONCLUSIONS: PLIF increased the ROM and maximum von Mises stress in adjacent cranial segments. The preservation of the proximal multifidus muscle contributes to the maintenance of the physiological mechanical behavior of adjacent segments, thus preventing the occurrence and development of ASD. BioMed Central 2023-06-24 /pmc/articles/PMC10290411/ /pubmed/37355581 http://dx.doi.org/10.1186/s12891-023-06649-7 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Wei, Wei
Wang, Tianhao
Liu, Jianheng
Mao, Keya
Pan, Chun’ang
Li, Hui
Zhao, Yongfei
Biomechanical effect of proximal multifidus injury on adjacent segments during posterior lumbar interbody fusion: a finite element study
title Biomechanical effect of proximal multifidus injury on adjacent segments during posterior lumbar interbody fusion: a finite element study
title_full Biomechanical effect of proximal multifidus injury on adjacent segments during posterior lumbar interbody fusion: a finite element study
title_fullStr Biomechanical effect of proximal multifidus injury on adjacent segments during posterior lumbar interbody fusion: a finite element study
title_full_unstemmed Biomechanical effect of proximal multifidus injury on adjacent segments during posterior lumbar interbody fusion: a finite element study
title_short Biomechanical effect of proximal multifidus injury on adjacent segments during posterior lumbar interbody fusion: a finite element study
title_sort biomechanical effect of proximal multifidus injury on adjacent segments during posterior lumbar interbody fusion: a finite element study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10290411/
https://www.ncbi.nlm.nih.gov/pubmed/37355581
http://dx.doi.org/10.1186/s12891-023-06649-7
work_keys_str_mv AT weiwei biomechanicaleffectofproximalmultifidusinjuryonadjacentsegmentsduringposteriorlumbarinterbodyfusionafiniteelementstudy
AT wangtianhao biomechanicaleffectofproximalmultifidusinjuryonadjacentsegmentsduringposteriorlumbarinterbodyfusionafiniteelementstudy
AT liujianheng biomechanicaleffectofproximalmultifidusinjuryonadjacentsegmentsduringposteriorlumbarinterbodyfusionafiniteelementstudy
AT maokeya biomechanicaleffectofproximalmultifidusinjuryonadjacentsegmentsduringposteriorlumbarinterbodyfusionafiniteelementstudy
AT panchunang biomechanicaleffectofproximalmultifidusinjuryonadjacentsegmentsduringposteriorlumbarinterbodyfusionafiniteelementstudy
AT lihui biomechanicaleffectofproximalmultifidusinjuryonadjacentsegmentsduringposteriorlumbarinterbodyfusionafiniteelementstudy
AT zhaoyongfei biomechanicaleffectofproximalmultifidusinjuryonadjacentsegmentsduringposteriorlumbarinterbodyfusionafiniteelementstudy