Frequency of prothrombin time-international normalized ratio monitoring and the long-term prognosis in patients with mechanical valve replacement

BACKGROUND: The study aimed to assess the correlation between the monitoring frequency of PT-INR and the long-term prognosis in patients with mechanical heart valve (MHV) replacement after discharge. METHODS: This single-center, observational study enrolled patients who underwent MHV replacement and...

Descripción completa

Detalles Bibliográficos
Autores principales: Geng, Le, Gu, Jiaxi, Li, Minghui, Liu, Hong, Sun, Haoliang, Ni, Buqing, Gu, Weidong, Shao, Yongfeng, Li, Mingfang, Chen, Minglong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10290782/
https://www.ncbi.nlm.nih.gov/pubmed/37355558
http://dx.doi.org/10.1186/s12872-023-03293-w
Descripción
Sumario:BACKGROUND: The study aimed to assess the correlation between the monitoring frequency of PT-INR and the long-term prognosis in patients with mechanical heart valve (MHV) replacement after discharge. METHODS: This single-center, observational study enrolled patients who underwent MHV replacement and discharged from June 2015 to May 2018. Patients or their corresponding family members were followed with a telephone questionnaire survey in July-October 2020. Based on monitoring intervals, patients were divided into frequent monitoring (FM) group (≤ 1 month) and less frequent monitoring (LFM) group (> 1 month). The primary endpoint was the composite of thromboembolic event, major bleeding or all-cause death. The secondary endpoints were thromboembolic event, major bleeding or all-cause death, respectively. RESULTS: A total of 188 patients were included in the final analysis. The median follow-up duration was 3.6 years (Interquartile range: 2.6 to 4.4 years). 104 (55.3%) patients and 84 (44.7%) patients were classified into the FM group and the LFM group, respectively. The FM group had a significantly lower incidence of the primary endpoint than the LFM group (3.74 vs. 1.16 per 100 patient-years, adjusted HR: 3.31 [95% CI 1.05–10.42, P = 0.041]). Secondary analysis revealed that the risk of thromboembolic events and all-cause death were also reduced in the FM group. CONCLUSIONS: The management of warfarin treatment in patients after MHV replacement remains challenging. Patients with less frequent monitoring of PT-INR might have worse clinical prognosis than those with frequent PT-INR monitoring. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12872-023-03293-w.