Frequency of prothrombin time-international normalized ratio monitoring and the long-term prognosis in patients with mechanical valve replacement

BACKGROUND: The study aimed to assess the correlation between the monitoring frequency of PT-INR and the long-term prognosis in patients with mechanical heart valve (MHV) replacement after discharge. METHODS: This single-center, observational study enrolled patients who underwent MHV replacement and...

Descripción completa

Detalles Bibliográficos
Autores principales: Geng, Le, Gu, Jiaxi, Li, Minghui, Liu, Hong, Sun, Haoliang, Ni, Buqing, Gu, Weidong, Shao, Yongfeng, Li, Mingfang, Chen, Minglong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10290782/
https://www.ncbi.nlm.nih.gov/pubmed/37355558
http://dx.doi.org/10.1186/s12872-023-03293-w
_version_ 1785062563802775552
author Geng, Le
Gu, Jiaxi
Li, Minghui
Liu, Hong
Sun, Haoliang
Ni, Buqing
Gu, Weidong
Shao, Yongfeng
Li, Mingfang
Chen, Minglong
author_facet Geng, Le
Gu, Jiaxi
Li, Minghui
Liu, Hong
Sun, Haoliang
Ni, Buqing
Gu, Weidong
Shao, Yongfeng
Li, Mingfang
Chen, Minglong
author_sort Geng, Le
collection PubMed
description BACKGROUND: The study aimed to assess the correlation between the monitoring frequency of PT-INR and the long-term prognosis in patients with mechanical heart valve (MHV) replacement after discharge. METHODS: This single-center, observational study enrolled patients who underwent MHV replacement and discharged from June 2015 to May 2018. Patients or their corresponding family members were followed with a telephone questionnaire survey in July-October 2020. Based on monitoring intervals, patients were divided into frequent monitoring (FM) group (≤ 1 month) and less frequent monitoring (LFM) group (> 1 month). The primary endpoint was the composite of thromboembolic event, major bleeding or all-cause death. The secondary endpoints were thromboembolic event, major bleeding or all-cause death, respectively. RESULTS: A total of 188 patients were included in the final analysis. The median follow-up duration was 3.6 years (Interquartile range: 2.6 to 4.4 years). 104 (55.3%) patients and 84 (44.7%) patients were classified into the FM group and the LFM group, respectively. The FM group had a significantly lower incidence of the primary endpoint than the LFM group (3.74 vs. 1.16 per 100 patient-years, adjusted HR: 3.31 [95% CI 1.05–10.42, P = 0.041]). Secondary analysis revealed that the risk of thromboembolic events and all-cause death were also reduced in the FM group. CONCLUSIONS: The management of warfarin treatment in patients after MHV replacement remains challenging. Patients with less frequent monitoring of PT-INR might have worse clinical prognosis than those with frequent PT-INR monitoring. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12872-023-03293-w.
format Online
Article
Text
id pubmed-10290782
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-102907822023-06-26 Frequency of prothrombin time-international normalized ratio monitoring and the long-term prognosis in patients with mechanical valve replacement Geng, Le Gu, Jiaxi Li, Minghui Liu, Hong Sun, Haoliang Ni, Buqing Gu, Weidong Shao, Yongfeng Li, Mingfang Chen, Minglong BMC Cardiovasc Disord Research BACKGROUND: The study aimed to assess the correlation between the monitoring frequency of PT-INR and the long-term prognosis in patients with mechanical heart valve (MHV) replacement after discharge. METHODS: This single-center, observational study enrolled patients who underwent MHV replacement and discharged from June 2015 to May 2018. Patients or their corresponding family members were followed with a telephone questionnaire survey in July-October 2020. Based on monitoring intervals, patients were divided into frequent monitoring (FM) group (≤ 1 month) and less frequent monitoring (LFM) group (> 1 month). The primary endpoint was the composite of thromboembolic event, major bleeding or all-cause death. The secondary endpoints were thromboembolic event, major bleeding or all-cause death, respectively. RESULTS: A total of 188 patients were included in the final analysis. The median follow-up duration was 3.6 years (Interquartile range: 2.6 to 4.4 years). 104 (55.3%) patients and 84 (44.7%) patients were classified into the FM group and the LFM group, respectively. The FM group had a significantly lower incidence of the primary endpoint than the LFM group (3.74 vs. 1.16 per 100 patient-years, adjusted HR: 3.31 [95% CI 1.05–10.42, P = 0.041]). Secondary analysis revealed that the risk of thromboembolic events and all-cause death were also reduced in the FM group. CONCLUSIONS: The management of warfarin treatment in patients after MHV replacement remains challenging. Patients with less frequent monitoring of PT-INR might have worse clinical prognosis than those with frequent PT-INR monitoring. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12872-023-03293-w. BioMed Central 2023-06-24 /pmc/articles/PMC10290782/ /pubmed/37355558 http://dx.doi.org/10.1186/s12872-023-03293-w Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Geng, Le
Gu, Jiaxi
Li, Minghui
Liu, Hong
Sun, Haoliang
Ni, Buqing
Gu, Weidong
Shao, Yongfeng
Li, Mingfang
Chen, Minglong
Frequency of prothrombin time-international normalized ratio monitoring and the long-term prognosis in patients with mechanical valve replacement
title Frequency of prothrombin time-international normalized ratio monitoring and the long-term prognosis in patients with mechanical valve replacement
title_full Frequency of prothrombin time-international normalized ratio monitoring and the long-term prognosis in patients with mechanical valve replacement
title_fullStr Frequency of prothrombin time-international normalized ratio monitoring and the long-term prognosis in patients with mechanical valve replacement
title_full_unstemmed Frequency of prothrombin time-international normalized ratio monitoring and the long-term prognosis in patients with mechanical valve replacement
title_short Frequency of prothrombin time-international normalized ratio monitoring and the long-term prognosis in patients with mechanical valve replacement
title_sort frequency of prothrombin time-international normalized ratio monitoring and the long-term prognosis in patients with mechanical valve replacement
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10290782/
https://www.ncbi.nlm.nih.gov/pubmed/37355558
http://dx.doi.org/10.1186/s12872-023-03293-w
work_keys_str_mv AT gengle frequencyofprothrombintimeinternationalnormalizedratiomonitoringandthelongtermprognosisinpatientswithmechanicalvalvereplacement
AT gujiaxi frequencyofprothrombintimeinternationalnormalizedratiomonitoringandthelongtermprognosisinpatientswithmechanicalvalvereplacement
AT liminghui frequencyofprothrombintimeinternationalnormalizedratiomonitoringandthelongtermprognosisinpatientswithmechanicalvalvereplacement
AT liuhong frequencyofprothrombintimeinternationalnormalizedratiomonitoringandthelongtermprognosisinpatientswithmechanicalvalvereplacement
AT sunhaoliang frequencyofprothrombintimeinternationalnormalizedratiomonitoringandthelongtermprognosisinpatientswithmechanicalvalvereplacement
AT nibuqing frequencyofprothrombintimeinternationalnormalizedratiomonitoringandthelongtermprognosisinpatientswithmechanicalvalvereplacement
AT guweidong frequencyofprothrombintimeinternationalnormalizedratiomonitoringandthelongtermprognosisinpatientswithmechanicalvalvereplacement
AT shaoyongfeng frequencyofprothrombintimeinternationalnormalizedratiomonitoringandthelongtermprognosisinpatientswithmechanicalvalvereplacement
AT limingfang frequencyofprothrombintimeinternationalnormalizedratiomonitoringandthelongtermprognosisinpatientswithmechanicalvalvereplacement
AT chenminglong frequencyofprothrombintimeinternationalnormalizedratiomonitoringandthelongtermprognosisinpatientswithmechanicalvalvereplacement